cover
Contact Name
Calvin E. J. Mamahit
Contact Email
calvinmamahit@unima.ac.id
Phone
+6282189240852
Journal Mail Official
jurnal.edunitro@gmail.com
Editorial Address
Gedung Jurusan PTE, Fakultas Teknik, Jalan Kampus Unima, Kelurahan Tonsaru, Kecamatan Tondano Selatan, Kabupaten Minahasa, Sulawesi Utara.
Location
Kab. minahasa,
Sulawesi utara
INDONESIA
Jurnal Edunitro
ISSN : 27762920     EISSN : 2776284X     DOI : https://doi.org/10.53682/edunitro
Jurnal Edunitro (E-ISSN 2776-284X dan P-ISSN 2776-2920) dikelola oleh Jurusan Pendidikan Teknik Elektro, Fakultas Teknik, Universitas Negeri Manado. Jurnal ini menyediakan sarana ilmiah terbuka bagi ilmuwan, akademisi, mahasiswa, guru dan praktisi industri untuk mempromosikan pengetahuan keahlian teknik elektro, temuan penelitian, serta inovasi terbaru dalam manajemen pendidikan dan pelatihan kejuruan. Ruang lingkup jurnal meliputi hasil penelitian keilmuan, pendidikan dan pelatihan di bidang teknik elektro, serta manajemen pendidikan dan pelatihan kejuruan. Jurnal ini menerbitkan dua edisi setiap tahun pada bulan April dan Oktober.
Articles 24 Documents
Search results for , issue "Vol. 3 No. 1 (2023): April Issue" : 24 Documents clear
Analysis and Design of Lighting at the UNIMA Workshop Building Pangestu, Prayogi; Seke, Fransiskus; Sangi, Nontje; Angmalisang, Harrychoon; Baharudin, Baharudin
JURNAL EDUNITRO Jurnal Pendidikan Teknik Elektro Vol. 3 No. 1 (2023): April Issue
Publisher : Department of Electrical Engineering Education, Faculty of Engineering, State University of Manado

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.53682/edunitro.v3i1.5595

Abstract

The need for natural and artificial lighting is a supporting component in daily human activities outside and inside buildings. For lighting to be carried out properly, it must meet the requirements stated in SNI and Minister of Health Regulation No. 70 of 2016 concerning Standard Requirements for Light Intensity. One of the goals of lighting in a building is to create sufficient lighting and reduce the risk of accidents. Referring to the description, the author is interested in understanding and researching further the existing lighting standards in the UNIMA Workshop building. In evaluating, the authors obtain research data by conducting case studies in which data is collected, processed, compared and analyzed. The results showed that the light intensity in the UNIMA Workshop room had an average of 144.2 lux and in the work area of 191.06 lux.
Application of Smart Relay Software in 3-Phase Motor Practice at SMKN 2 Bitung Lagu, Alsius; Wardana, I Gede
JURNAL EDUNITRO Jurnal Pendidikan Teknik Elektro Vol. 3 No. 1 (2023): April Issue
Publisher : Department of Electrical Engineering Education, Faculty of Engineering, State University of Manado

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.53682/edunitro.v3i1.5752

Abstract

This study aims to detect practical errors to minimize circuit errors. This research was carried out at SMK Negeri 2 Bitung in the even semester of the 2021/2022 academic year. The research method used is descriptive analysis research using quantitative and qualitative approaches. The data collection technique consists of three stages: observation, statements based on Bloom's taxonomy, and documentation. The subjects of this research were 25 students from class XII. The research instrument used is a statement based on Bloom's taxonomy which has gone through the validation stage of the supervisor. The results of this study are to minimize the occurrence of 3-Phase Motor Practice errors with the application of Smart Relay software for 25 students. The results showed they dominated with friendly answers regarding students' understanding of using Smart Relay software. Based on students' attitudes in using Smart Relay software, they dominate with agreeing answers, and so on, aspects of students' skills in using Smart Relay software dominate with agreeing answers. It was also obtained from student learning outcomes that understanding the Smart Relay software got an average score of 84.2.
Analysis of the Human Body's Resistance to AC Voltage Kilis, Billy; Tuegeh, Maickel; Dako, Rahmat; Memah, Viverdy; Ticoh, Janne
JURNAL EDUNITRO Jurnal Pendidikan Teknik Elektro Vol. 3 No. 1 (2023): April Issue
Publisher : Department of Electrical Engineering Education, Faculty of Engineering, State University of Manado

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.53682/edunitro.v3i1.5764

Abstract

The economic development of the community affects the widespread use of household electricity. Of course, the development of technology touches every aspect of the activity, whether for entertainment, pleasure or primary needs. Every dry season, the threat of fire is often a scourge for all of us. One of the leading causes is a short circuit of electric current. Electricity is an essential part of this day and age. Everyone needs electricity, whether it is from the lower levels of society to the upper levels of society, both for household, office and industrial purposes. Specifically for household purposes, electricity has become an inseparable part of daily needs. A pandemic has resulted in more extended and varied use of electricity in the home. Another consequence is that it is more prone to short circuits or even fires. The critical criteria that must be met at home are the proper installation of security fuses, the avoidance of sockets with multiple connections, and other items that must guarantee adequate grounding or fulfil the requirements with installations that meet the General Electrical Installation Requirements (in Bahasa Indonesia is abbreviated as PUIL). Problems that can be identified are: What is the average resistance of the student body to AC voltage? Are there any differences in male and female body resistance? The benefits of this research are: Theoretical benefits assessing the average resistance of the human body for planning protection system equipment. Practical benefits it is known as the average student body resistance value. Become a reference in determining the value of a protection system plan. The average measurement results in the range of 5100 Ohm. The results showed a significant difference between the levels of body resistance of male and female students. This is because the number of female students in this study is much smaller than that of male students.
The Effect of Workshop Facilities on Practice Learning Outcomes of Students of SMKN 1 Tomohon Mohammad Saleh, Ainun; Mandagi, Gilbert; Kaligis, Gery
JURNAL EDUNITRO Jurnal Pendidikan Teknik Elektro Vol. 3 No. 1 (2023): April Issue
Publisher : Department of Electrical Engineering Education, Faculty of Engineering, State University of Manado

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.53682/edunitro.v3i1.5779

Abstract

The purpose of the study was to determine the effect of workshop facilities on students' learning outcomes of electrical power installation engineering practice at SMK Negeri 1 Tomohon. The research method used is a quantitative descriptive method with a simple regression technique. The research population was all Class XI students, Department of Electrical Power Installation Engineering, which amounted to 30 people. The research sample was the entire population, Class XI students of the Department of Electrical Power Installation Engineering, which amounted to 30 people. Workshop facilities are one of the external factors that can improve students' learning outcomes of electrical power installation engineering practice at SMK Negeri 1 Tomohon. The formulation of the research problem is whether there is an influence of workshop facilities on the learning outcomes of students' electrical power installation engineering practice at SMK Negeri 1 Tomohon. The research instrument used to measure workshop facilities was a questionnaire, while for student learning outcomes, it was through a learning evaluation. The study concludes that workshop facilities affect the learning outcomes of electric power installation engineering practices for students of SMK Negeri 1 Tomohon. The study results evidence this obtained a significance value of 0.000 <0.05, and the t-count value is more significant than t-table, namely t-count = 11.191 > t-table 2.048. With the magnitude of the influence of 81.7%.

Page 3 of 3 | Total Record : 24