cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
-
Editorial Address
-
Location
Kota adm. jakarta selatan,
Dki jakarta
INDONESIA
Prima Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir
ISSN : -     EISSN : -     DOI : -
Core Subject : Science,
Jurnal Prima Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir, Jurnal ilmiah diterbitkan oleh Pusat Rekayasa Perangkat Nuklir - BATAN Alamat Rekaksi: Pusat Rekayasa Perangkat Nuklir (PRPN) - BATAN
Arjuna Subject : -
Articles 228 Documents
PEREKAYASAAN SISTEM DETEKSI PERANGKAT SCINTIGRAPHY MENGGUNAKAN PSPMT Wiranto Budi Santoso; Leli Yuniarsari
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 8, No 2 (2011): Nopember 2011
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (933.946 KB)

Abstract

THE ENGINEERING OF A SCINTIGRAPHY EQUIPMENT DETECTION SYSTEMUSING PSPMT. The engi neering of sci ntigraphy equipment detection  system usi ng PSPMT has been conducted. A scintigraphy equipment i s used for imagi ng small organs. The equipment is a mini gamma camera. The function of the equi pment to provide images of metboli sm processn a body organ. The result of the equipment can be used to diagnose an il lness. The function of scintigraphy equipment detection system is  detecti ng incomi ng radiati on from body organs. The ncoming radi ati ons are converted to photons by a scintillati on crystal in the scinti graphyequipment detection system.  Then, photons are multiplied by Photo Multipl ier Tube (PMT) and are converted to be el ectrical si gnals. It needs a l ot of PMT to detect a locati on of incoming radiation from a body organ. Using PSPMT (Posi tion Sensitive PMT) which sensiti ve to positi onof incomi ng radiation, it  needs only one PSPMT.  From this activity, it can be concluded that PSPMT can be used for  scintigraphy equipment  etection system. Usi ng PSPMT, the dimension of scintigraphy equi pment detection system can be reduced. Although the scintigraphy equipment detection system i s only suit able for imagi ng small organs. PEREKAYASAAN SISTEM DETEKSI PERANGKAT SCINTIGRAPHY MENGGUNAKAN PSPMT. Telah dilakukan perekayasaan sistem deteksi  perangkat scintigraphy menggunakan PSPMT. Perangkat scintigraphy merupakan perangkat untuk pencitraan organ tubuh berukuran kecil . Perangkat i ni  merupakan kamera gamma dalam bentuk mini. Perangkat ini berfungsi untuk menghasilkan citra proses metabolisme suatu organ tubuh. Keluaran dari perangkat ini digunakan untuk diagnosis suatu penyakit. Sistem deteksi  perangkat scintigraphy berfungsi untuk mendeteksi radiasi dari organ tubuh. Radiasi yang datang akan diubah menjadi  foton oleh kristal  sintilasi yang terdapat pada sistem deteksi  perangkat scinti graphy. Kemudian foton tesebut akan digandakan ol eh tabung  pengganda foton (Photo Multipl ier Tube – PMT) dan diubah menj adi sinyal listrik. Diperlukan banyak PMT untuk  mendeteksi lokasi datangnya radi asi  dari  organ tubuh. Dengan menggunakan PSPMT (Posi ti on Sensiti ve PMT) yang sensitif terhadap posisi datangnya radiasi, hanya diperl ukan satu PSPMT. Dari kegiatan yang di lakukan dapat disimpul kan bahwa sistem deteksi perangkat scinti graphy dapat menggunakan PSPMT. Dengan menggunakan PSPMT, dimensi sistem deteksi perangkat scintigraphy dapat diperkecil . Namun sistem deteksi hanya cocok di  unakan untuk mencitrakan organ yang kecil.
PERANCANGAN TRAFO TEGANGAN TINGGI UNTUK CATU DAYA PEMERCEPAT ELEKTRON PADA TABUNG SINAR-X RADIOGRAFI Yadi Yunus; Suyamto Suyamto
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 11, No 1 (2014): Juni 2014
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (403.003 KB)

Abstract

ABSTRAK PERANCANGAN TRAFO tegangan tinggi UNTUK Catu Daya Pemercepat Elektron PADA TABUNG SINAR-X RADIOGRAFI.  Menuju kemandirian teknologi telah dirancang Trafo untuk Pemercepat Elektron Pada Tabung Sinar-X Radiografi. Tujuan kegiatan ini untuk mendapatkan rancangan sebagai acuan dalam membangun  sebuah trafo tegangan tinggi yang dapat digunakan baik pada tabung pesawat Sinar-X Industri maupun Medik.Trafo dirancang dengan daya beban penuh 8.500 VA, 220V/250 kV, model inti berbentuk cruciform dengan pendingin dan isolator Oli Diala B. Setelah dihitung dan dirancang kemudian dievalusai rugi-rugi tegangan, rugi- rugi daya, efisiensi, arus beban kosong, regulasi tegangan, kuat isolasi hingga kenaikan suhunya. Hasil rancangan adalah trafo dengan penampang inti ± 62 cm2, panjang  ± 167,54 cm, dan berat 73,6 kg. Kawat primer 8 mm2,diameter 3,4mm, berat ± 4,2 kg, sekunder 0,007 mm2, diameter 0,26 mm, berat ± 36 kg . Berdasar hasil analisis, dapat disimpulkan bahwa pada beban penuh prosen regulasi tegangan 3,5 %, efisiensi 95,3 %, arus tanpa beban 5,96 A, beban maksimum kontinyu kenaikan suhu 37 0C.  Katakunci: Trafo tegangan tinggi GCT, isolasi tegangan tinggi, pemercepat elektron, tabung Sinar-X ABSTRACT DESIGN OF  HIGH VOLTAGE TRANSFORMER FOR POWER SUPPLY OF ELECTRON ACCELARATOR ON RADIOGRAPHY X-RAY TUBE. Transformers for Electron Accelerators In Radiography X-Ray Tube has been designed. It aims to get a reference in, builds high voltage transformer which can be used either on the X-ray machines tube for Industry and Medic. Power transformer is designed with a full load 8,500 VA, 220V/250 kV, cruciform-shaped core, with coolant and insulator is Diala B Oil. The result of calculations is the transformer cross-sectional  of core ± 62 cm2, the length ± 167.54 cm and weigh of core 73.6 kg. The primary coil with a cross section of wire 8 mm2  diameter ± 3.4 mm, total weight 4.2 kg, secondary of 0.007 mm2, diameter 0.26 mm and with weight of 36 kg. Results of analysis showed that voltage regulation percentage at full load is 3.5%, efficiency of 95.3%, exciting current is5.96 A and the maximum temp rise is 37 0C.Keywords : GCT high voltage transformer, high voltage insulation, electron accelerator, X-ray tube.
DESAIN SISTEM PENGGERAK SELING SUMBER ISOTOP IRIDIUM-192 PADA BRAKITERAPI KANKER SERVIK DOSIS SEDANG Ari Satmoko; Sanda Sanda; Tri Harjanto; Atang Susila
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 7, No 14 (2010): Nopember 2010
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1021.131 KB)

Abstract

DESAIN SISTEM PENGGERAK SELING SUMBER ISOTOP IRIDIUM-192 PADA BRAKITERAPI KANKER SERVIK DOSIS SEDANG. Kegiatan perekayasaan brakiterapi pada tahun 2010 bertujuan untuk menghasilkan desain rinci perangkat brakiterapi kanker servik dosis sedang dengan memanfaatkan sumber isotop Iridium-92 berdaya pancar antara 5 hingga 10 Curie. Sumber dibungkus dalam kapsul stainless steel SS-316 yang dirangkai dengan seling SS-316 berdiameter sekitar 1 mm dan panjang 1800 mm. Sebagai bagian dari kegiatan ini, desain awal sistem mekanik penggerak sumber isotop telah dikembangkan. Kegiatan telah berhasil menentukan spesifikasi teknis komponen-komponen utama sistem mekanik penggerak. Kegiatan diawali dengan mempelajari desain konsep, melakukan perhitungan dan menentukan spesifikasi teknis, serta menetapkan komponen utama. Dari berbagai evaluasi yang telah dilakukan, beberapa komponen telah diputuskan yaitu motor stepper PK264A1- SG10, bearing tipe jarum NKI-10/20, tabung spiral berdiameter 120 mm berbahan SS316-1/8", sabuk berbahan dasar karet dengan lebar 20 mm, serta drum besar berdiameter 100 mm berbahan aluminium. Tidak semua komponen dapat diidentifikasikan secara detil terutama komponen yang tidak ada di pasar dan harus dibuat sendiri. Dengan telah ditentukannya komponen-komponen utama tersebut, maka kegiatan lanjutan berupa desain rinci sistem mekanik penggerak seling sumber isotop dapat dilakukan. A MECHANICAL SYSTEM DESIGN OF THE IRIDIUM-192 ISOTOPE WIRE IN CERVICAL CANCER BRACHYTERAPHY WITH MEDIUM DOSE RATE. In 2010, brachytherapy engineering development activities have a purpose to establish a detailed design of the cervical cancer rachiteraphy with medium dose rate. The brachyteraphy will use an Iridium-92 source with the emiting radiation of 5 to 10 Curies. The source is wrapped in SS-316 capsule and carried by a SS-316 wire having diameter of about 1 mm dan length of 1800 mm. As part of this activity, the preliminary design of the mechanical drive systems for the isotope source has been developed. The technical specifications for the main components of the mechanical drive system have been successfully determined. This is started by studying the concept design, performing calculations, determining technical specifications, and finally defining the main components. From the evaluation, some components were decided: a stepper motor PK264A1-SG10, needle bearing NKI-10/20, spiral tube in SS316-1/8" with 120 mm in diameter, rubber-based belts with a width of 20 mm, and aluminium drum with a diameter of 100 mm. Not all components could be identified in detail, especially for the components that do not exist in the marketplace and have to be created ourself Since the main components have been identified, the detailed design step of the mechanical drive systems for the isotope source can be performed. Keywords: brachyteraphy, wire, source, drive
PENGUJIAN KARAKTERISTIK MINYAK TRANSFORMATOR GEDUNG 72 BATAN SERPONG Suripto Suripto
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 13, No 2 (2016): November 2016
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (4616.343 KB)

Abstract

ABSTRAKPENGUJIAN KARAKTERISTIK MINYAK TRANSFORMATOR GEDUNG 72 BATAN. Telah dilakukan pengujian karakteristik minyak transformator gedung 72 BATAN. Transformator adalah salah satu alat penunjang ketersediaan listrik. Tugas transformator adalah merubah tegangan dari tegangan menengah menjadi tegangan yang lebih rendah dan juga sebaliknya. Untuk menjaga kehandalan dan memperpanjang usia dari transformator diperlukan beberapa tindakan, diantaranya pengujian terhadap minyak tranformator yang bertujuan untuk mengetahui kelayakan/ memenuhi persyaratan sebagai media pendingin dan isolasi dalam transformator. Pada kenyataan dilapangan seringkali transformator dianggap hanya merupakan alat bantu yang hanya diingat dan diperlukan apabila pada saat arus listrik dari PLN padam sehingga dalam hal perawatan seringkali terabaikan dan terbengkalai. Untuk itu pemantauan dan pemeliharaan kualitas minyak transformator sangat penting guna menjamin keandalan operasi nya.  Dengan demikian umur transformator diharapkan dapat mencapai ~40 tahun dan minyak transformator yang kualitasnya sangat baik diharapkan setara masa pakainya dengan masa hidup transformator tersebut.Kata kunci : Transformator, minyak transformator, pengujian, tegangan tembus. ABSTRACTA CHARACTERISTICS TESTING OF THE TRANSFORMER OIL AT THE BATAN BUILDING 72.  A characteristics testing of the transformer oil at the BATAN building 72 has been carried out. Transformer is one of the tools in supporting the availability of electricity. The task is to change a high voltage into a lower voltage and vice versa. To maintain the reliability and extend the life of the transformer, several actions are required, including testing of transformer oil which aims to determine the feasibility / qualified as a coolant and insulation in transformers. In fact the transformer is often to be considered merely as a tool that only to be remembered and required if at the time the electricity is black out so that in terms of its maintenance program is often neglected and abandoned. The monitoring and maintenance of the transformer oil quality are imperative to guarantee the reliability of its operation. Thus the life of the transformer will be expected to reach ~40 years and the transformer oil which has excellent quality will be expected the same to the lifetime of the transformer.Keywords : Transformer, transformer oil, testing, breakdown voltage.
RANCANGAN SISTEM MONITORING RADIASI GAMMA LINGKUNGAN STACK MONITOR RSG Benar Bukit
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 6, No 12 (2009): Nopember 2009
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (151.959 KB)

Abstract

ABSTRAK Rancangan Sistem Monitoring Radiasi Gamma Lingkungan Stack Monitor RSG. Telah dirancang suatu sistem pencacah dan pemantau radiasi gamma untuk digunakan di suatu instalasi nuklir. Alat ini dirancang untuk memantau radiasi gamma yang dilepas ke lingkungan selama operasi suatu instalasi nuklir. Efluen radioaktif harus diperhatikan secara intensif. Dalam keadaan normal,  biasanya dihasilkan produk samping bahan radioaktif. Produk samping padat biasanya dikungkung di daerah terkendali, tetapi lepasnya produk samping gas dan voletil ke lingkungan sulit dicegah. Selain itu Radionuklida hasil fisi antara lain seperti Cs-137 pemancar gamma, dan Sr-90  adalah pemancar beta. Masing-masing memiliki masa paruh yang panjang yaitu 30 tahun dan 28 tahun.Pemantauan efluen-efeluen tersebut dan tingkat radioaktifitas dalam suatu instalasi nuklir harus dilakukan terus-menerus supaya peningkatan radiasi atau radioaktifitas lingkungan dapat diketahui dengan segera. Degan demikian, perlu dirancang suatu sistem pemantauan on-line. Sistem yang dirancang di sini untuk memenuhi kebutuhan tersebut terdiri dari suatu sistem diteksi, suatu sistem komunikasi data, dan suatu sistem pengolah data. Setelah terpasang, sistem pemantau radiasi lingkungan ini memantau lingkungan secara otomatis. Data yang dihasilkan sistem detektor dikirim secara on-line ke unit pengolah data melalui sistem komunikasi nirkabel. Data ini dapat dioleh menjadi tabel, grafik, animasi maupun tanda-tanda peringatan. Kata kunci : radioaktif, data logger, on-line monitoring, wireless ABSTRACT The Design of a Gamma Radiation Environmental Monitoring Syste for Stack Monitor at RSGm. A gamma radiation counting and monitoring system for use in a nuclear installation was designed. This equipment is designed for monitoring gamma radiation released to the environment during the operation of a nuclear installation. Any radioactive effluents have to be intensively examined. During normal situations, some radioactive byproducts usually occur. Solid radioactive byproducts are confined in controlled areas, but gaseous and voltile by products are difficult to prevent from escaping to the environment. Further, fission product radio nuclides such as Cs-137 and Sr-90 also occur. Cs-137 is a beta and gamma emitter, while Sr-90 is beta emitter, and both have long half times of 30 and 28 years, respectively.Those  effluents  and  the  radioactive  level  in  a  nuclear  installation have  to  be  continually monitored so that any increases in radiation or environmental radioactivity level is detected immediately. Thus, an on-line monitoring system has to be designed. The  system  designed  here  to  fulfill  that  need  consists  of  detection  system,  a  data communication  system,  and  a  data  processing  system.  After  installed,  the  environmental radiation monitoring system automatically monitors the environment.The data produce by the detector is sent on-line to the data processing center through wireless communication system. The data could be processed into table, graphs, animations and alarms. Keyword : Radioactive, on-line monitoring, wireless. 
NEURAL NETWORK FOR RECOGNIZING SIGNAL-SHAPE•OF NUCLEAR DETECTOR OUTPUT Mardiyanto M Panitra
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 3, No 5 (2006): Juni 2006
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1605.491 KB)

Abstract

ABSTRACTNEURAL   NETWORK   FOR  RECOGNIZING   SIGNAL-   SHAPE   OF  NUCLEAR   DETECTOR OUTPUT.  The   use of artificial  intelligent  technique  in the engineering  field has been  familiar especially  in the field of pattern  recognition. By using this technique either simple routine works or complicated routine works  can  be  done  by  the  help  of  a  d1g1tal  camera  and  a personal computer.. One of the complicated  works that can not be solved easily is how to separate  two kinds  of nuclear  radiation  types  wnich are mixed  in the same field.   The separation  of the two kinds of radiation  become is very important  for the radiation  dosimetry purposes.. For doing this we  have  carried   out  a  preliminary   research   in  applying   a  neural   network   technique   for recognizing  C and  T letters  with right, left, up, and down positions.  We arranged  a three-layer neural network i.e. input layer (9 neurons  with/without  1  bias neuron), hidden layer (11 neurons), and output  layer  (1 neuron).  From  this preliminary  study the use of a bias neuron  gave faster learning process  compared  with the one without the bias neuron.  The neural network could work successfully  in determining  the letter S and T without any mistake. ABSTRAKPENGGUNAAN NEURAL NETWORK UNTUK MEMBEDAKAN BENTUK SINYAL KELUARAN   DARI  SEBUAH  DETEKTOR  NUKLIR.  Pemakaian  teknik jaringan di dalam bidang keteknikan  sudah  sangat  dikenal  terutama  untuk  membedakan  bentuk  suatu  sinyal. Dengan menggunakan  teknik ini baik pekerjaan  rutin yang sederhana maupun pekerjaan  rutin yang sulit dapat dilakukan  secara otomatis dengan bantuan sebuah komputer pribadi dan sebuah kamera digital.  Dalam bidang dosimetri  nuklir, pemisahan  antara dua jenis  radiasi merupakan  hal yang sangat   penting. Untuk tujuan itu kami melakukan penelitian untuk menggunakan system jaringan  tiruan neural network untuk membedakan  dua buah huruf yakni huruf C dan  T dengan 4 posisi  yang  berbeda. Untuk tujuan itu digunakan jaringan tiruan dengan  9 input neuron, 11 neuron pada  lapisan  tengah dan  1   neuron pada keluarannya.  Dari penelitian  ini diperoleh  hasil bahwa dengan menggunakan  1 bias neuron pada lapisan input dapat mempercepat proses pembelajaran    yakni  dari 10 iterasi  menjadi  5 iterasi.   Setelah  dilakukan  pembelajaran  maka jaringan  mempu membedakan kedua huruf dalam 8 posisi tanpa adanya kesalahan.
PEMBUATAN DIAGRAM ALIR INSTRUMENTASI DAN PEMIPAAN UNTAI UJI SISTEM KENDALI REAKTOR RISET Tukiman Tukiman; Puji Santoso; Suwardiyono Suwardiyono; Muhammad Awaludin; Edi Purwanta
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 9, No 2 (2012): Nopember 2012
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (485.624 KB)

Abstract

A CONSTRUCTION OF INSTRUMENTATION FLOWCHART AND PIPING SYSTEM FOR TEST CIRCUIT OF RESEARCH REACTOR SYSTEM. A construction of instrumentation flowchart and piping system for test circuit of research reactor system has been conducted. The aim of the construction is to study the cooling process of primary and secondary cooling system of nulcear research reactor. Basic construction of this work is the requirement of primary and secondary cooling system of research reactor G.A. Siwabesy. The primary cooling water flow rate is 431 liter/hour at the heat exchanger, with outlet and inlet water temperature are 42oC and 41oC respectively. The secondary cooling water is taken fro, the cooling tower having flow rate 172 liter/hour, with outlet and inlet water temperature are 37oC and 32oC respectively. Austenit stainless steel pipe is used with the nominal composition of 18% Cr-8% Ni.B31.1 standard it is called A376/TP304 or SS 304. The pipe diameter is 1 inch, schedule 40S. Some types of valves are used to control the flow: gate valve, butterfly valve, solenoid valve, and check valve that are controlled using electric and manual method. From this design, the flowchart of instrumentation and piping is produced and usually called piping and instrumentation diagram.  PEMBUATAN DIAGRAM ALIR INSTRUMENTASI DAN PEMIPAAN UNTAI UJI SISTEM KENDALI REAKTOR RISET .Telah dilakukan pembuatan diagram alir sistem instrumentasi dan pemipaan untai uji sistem kendali reaktor riset. Tujuan dari pembuatan diagram alir adalah untuk mempelajari proses pendinginan primer dan sekunder sebuah reaktor riset. Dasar pembuatan dari sistem instrumentasi dan pemipaan ini adalah requirement sistem pendingin primer dan sekunder reaktor riset GA.Siwabesy. Laju alir air pendingin primer 431 liter/jam pada alat penukar panas, suhu air pendingin keluar 42oC dan suhu air masuk 40oC. Air pendingin sekunder diambil dari cooling tower dengan laju alir 172 liter/jam. dengan suhu air pendingin yang keluar dari cooling tower 37oC dan suhu air masuk 32oC.Pipa yang digunakan adalah jenis baja tahan karat austenit dengan komposisi nominal 18%Cr-8%Ni. Dalam standar ASME B31.1 disebut dengan pipa A 376/TP 304, atau SS 304. Diameter pipa 1 inch, schedule 40S. Untuk pengaturan aliran digunakan beberapa jenis valve : Gate valve, Buterfly valve, selenoid valve , check valve, yang dikendalikan dengan sistem kontrol secara elektrik maupun manual. Dari rancangan ini dihasilkan gambar diagram alir instrumentasi dan pemipaan atau yang sering disebut Piping & Instrumentasi Diagram
KARAKTERISASI FLAT- PANEL DETECTOR UNTUK PESAWAT SINAR-X DIGITAL I Putu Susila; Wiranto Budi Santoso; Istofa Istofa
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 10, No 2 (2013): November 2013
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (5276.407 KB)

Abstract

ABSTRAK KARAKTERISASI FLAT-PANEL DETECTOR UNTUK PESAWAT  SINAR-X DIGITAL. Pesawat Sinar-X  digital merupakan perangkat sinar-X  yang  tidak  memerlukan proses kimiawi seperti pada film sehingga biaya  operasionalnya rendah dan  ramah lingkungan. Selain  itu, citra hasil  pemeriksaan segera dapat diamati,  mudah disimpan dan  digandakan.  Didasari adanya keunggulan-keunggulan tersebut, saat ini di PRPN  – BATAN dilakukan  perekayasaan pesawat sinar-X   digital.  Penangkap  citra  yang   digunakan adalah  flat-panel  detektor  yang   berbasis silikon.  Untuk  mengetahui  karakteristik serta  kualitas  citra  yang   dihasilkan,  perlu  dilakukan pengujian  terhadap  detektor tersebut.  Pada  penelitian  ini,  pengujian  dilakukan   di  poliklinik PKTN-BATAN  menggunakan  pesawat  sinar-X   dengan  nilai  arus  sebesar  150mA,   nilai  kV diubah-ubah serta waktu expose selama 0,1 detik. Objek yang diambil citranya  adalah standard test   object,   PCB,   detector  NaI(Tl),  obeng  dan   tangan.  Selanjutnya,  citra   yang   diperoleh dianalisis secara kualitatif (pengamatan terhadap citra positif dan  negatif)  dan  kuantitatif.  Hasil analisis menunjukkan bahwa resolusi citra  adalah sebesar 3,7  ~ 4,0  LP/mm  dan  tidak  terjadi distorsi  geometri pada citra sinar-X.  Kualitas citra yang  ditunjukkan  dengan nilai signal-to-noise ratio (SNR),  semakin tinggi seiring  dengan meningkatnya nilai kV. Selanjutnya, perlu dilakukan koreksi  uniformity  agar  kualitas citra  tinggi  terutama pada nilai kV rendah. Sedangkan untuk contrast, pada objek  yang  perbedaan  intensitasnya sedikit, perbedaan tersebut akan  terlihat jelas apabila ditampilkan sebagai citra negatif.  Hasil-hasil  tersebut dapat dijadikan  acuan untuk interpretasi citra dan  pengembangan perangkat lunak pengolah citra.Kata kunci: Sinar-X,Flat-panel Detector,Radiografi Digital, Karakterisasi Flat Detektor,Kualitas Citra  ABSTRACT CHARACTERIZATION  OF  FLAT PANEL  DETECTOR FOR  DIGITAL X-RAY MACHINE.  The  digital  x-ray  equipment does  not  need chemical  process like  a film. The operational cost  is  then  low and  environment friendly.  In addition,  the  image  can  be  viewed immediately and  can  easily be  stored and  copied. Based on these advantages, PRPN-BATAN develops a digital x-ray machine which uses silicon-based flat-panel  detector to produce x-ray digital  image. To  understand the  characteristic of the  detector and  quality of the  images, a characterization is  needed. In this  study,  the  experiment was conducted at  polyclinic  PKTN- BATAN, utilizing an existing  x-ray generator. During experiment, the filament current  was set  to 150mA, varied  the voltage  and exposure time was set to 0.1 second. Standard test  object,  PCB, NaI(Tl) detector, toolset  and  hand  were  utilized  as testing  objects. The  acquired images then were    being    analyzed   qualitatively   (observation   of   positive    and    negative   image)    and quantitatively. It was shown  that  the  resolution is between 3.7  and 4.0  LP/mm  and  there  is no geometric distortion  occurred in the images. Image quality which is described by signal-to-noise ratio (SNR) is increasing as voltage increased. Uniformity correction is needed for images taken with lower voltage  value.  Finally, for object  which has nearly  same intensity,  the difference can be  seen  as  contrast difference  in  the   negative images.  These  results  can   be   utilized  as reference for images interpretation and image processing software development. Keywords:  X-Ray,Flat-panel Detector,Digital Radiography, Flat Detector Characterization,Image Quality
UJI KLINIS KELENJAR GONDOK DENGAN PERANGKAT THYROID UPTAKE Wahyuni Z. imran; Riswal Napi Siregar; Rony Djokorayono; Leli Yuniarsari
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 7, No 13 (2010): Juni 2010
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (762.719 KB)

Abstract

UJI KLINIS KELENJAR GONDOK DENGAN PERANGKAT THYROID UPTAKE. Telah dilakukan uji klinis kelenjar gondok dengan menggunakan perangkat thyroid uptake hasil rekayasa BATAN. Uji klinis ini dilakukan di RS Paru Ario Wirawan di Salatiga dengan cara mendeteksi daya tangkap iodium <sub>131<\sub> I oleh kelenjar gondok. Fungsi kelenjar gondok dapat diketahui dengan mengukur serapan radiofarmaka dalam kelenjar gondok dengan menempatkan detektor di depan leher pasien. Untuk mendapatkan hasil diagnosis yang cepat, penanganan dan pengolahan hasil pendeteksian ini digunakan perangkat thyroid uptake dengan antarmuka devasys USB yang dapat menerima data digital. Data ini diolah ke komputer untuk mendapatkan kurva uptake. Hasil ini dibandingkan dengan analisis darah pasien dengan menggunakan perangkat Radioimmunoassay. GOITER GLAND CLINICAL EXAMINATION USING THYROID UPTAKE EQUIPMENT.Goiter Gland Clinical examination using thyroid uptake equipment developed by BATAN has been performed. The clinical examination was performed in the Ario Wirawan Lung Hospital in Salatiga. The gland functionality was determined by measuring the absorption of <sub>131</sub> I by the qolier gland, which was performed by placing the detectors in front of the patient's throat. To obtain the diagnosis result rapidly, the thyroid uptake device equipped with a devasys USB interface csoebt« of receiving digital data. The data is processed by computer to obtain uptake curves. The result were then compared with the patient's blood analysis result obtained using standard Radioimmunoassay equipment.
MODIFIKASI DESAIN RANGKA SANDARAN KURSI PADA PERANGKAT RENOGRAF TERPADU Muhammad Awwaluddin; Tri Harjanto; Sanda Sanda; Joko Sumanto; Benar Bukit
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 12, No 2 (2015): November 2015
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (641.655 KB)

Abstract

ABSTRAKMODIFIKASI DESAIN RANGKA SANDARAN KURSI PADA PERANGKAT RENOGRAF TERPADU. Telah dilakukan modifikasi desain rangka sandaran kursi sebagai dudukan detektor untuk mendukung beroperasinya perangkat renograf terpadu. Modifikasi rangka dilakukan dengan mengganti struktur yang tadinya hollow carbon steel 25 x 25 mm dengan pipa carbon steel schedule 40 berukuran 3/4 inch dan hollow carbon steel ukuran 20 x 40 mm tebal 1,2 mm. Kemudian dilakukan analisis menggunakan software ANSYS dengan parameter pembebanan yang telah ditentukan. Hasil analisis menunjukkan tegangan maksimum yang terjadi sebesar 1,7219 x 108 Pa masih dibawah batas maksimalnya sebesar 2.4816 x 108 Pa sehingga dapat dinyatakan layak digunakan. Dengan modifikasi desain yang diajukan, maka pengoperasian perangkat renograf terpadu dapat dilakukan dengan aman.Kata kunci : Renograf Terpadu, Perangkat, Modifikasi Desain, Rangka. ABSTRACTDESIGN MODIFICATION FOR BACK SEAT FRAME ON INTEGRATED RENOGRAF EQUIPMENT. A the design modification of the back seat frame used as a detector holder to support the operation of the integrated renograf has been done. Modification of the framework is done by replacing the structure that was hollow carbon steel 25 x 25 mm with a schedule 40 carbon steel pipe measuring 3/4 inch and with the hollow carbon steel the measures is 20 x 40 mm in thickness of 1.2 mm. Then performed the analysis using ANSYS software with loading parameters have been determined. The analysis showed that the maximum stress occurs at 1,7219 x 108 Pa is still below the maximum limit of 2.4816 x 108 Pa to be declared fit for use. With the proposed design modifications,the operation of the integrated renograf can be safe. Keywords: Integrated Renograf, Device, Modification Design, Frame

Page 6 of 23 | Total Record : 228