cover
Contact Name
Dwi Agus Riyanto
Contact Email
faiq.nurraihan29@gmail.com
Phone
+6285257732360
Journal Mail Official
publikasi@sttnlampung.ac.id
Editorial Address
Jl. Pulau Damar Gg. Sapta Marga Kel. Waydadi Baru Kec. Sukarame Kota Bandar Lampung, Lampung, 35131 Indonesia
Location
Kota bandar lampung,
Lampung
INDONESIA
Journal of Electrical Engineering and Informatics (JEEI)
ISSN : 31640591     EISSN : 31250165     DOI : -
Core Subject :
The Journal of Electrical Engineering and Informatics (JEEI) is a peer-reviewed, open-access scientific journal dedicated to publishing high-quality original research and review papers that advance knowledge in electrical engineering and informatics. Serving as a scholarly platform for researchers, academics, practitioners, and industry professionals, the journal aims to foster interdisciplinary collaboration, exchange scientific ideas, and promote innovative research. By focusing on both theoretical foundations and applied research, JEEI seeks to publish rigorous and impactful works that address contemporary challenges and support digital transformation, intelligent systems, and sustainable technological development at national and international levels. In line with its objectives, JEEI accepts a wide range of manuscripts covering a comprehensive scope of contemporary engineering and information technologies. The journal welcomes contributions in core and emerging areas, including electrical power systems, smart grids, renewable energy technologies, electronics, instrumentation, and control systems. Furthermore, it strongly encourages submissions focused on modern digital and computing advancements, such as artificial intelligence, machine learning, the Internet of Things (IoT), embedded systems, robotics, signal and image processing, information systems, and other smart engineering applications.
Arjuna Subject : -
Articles 15 Documents
Implementation of YOLOv8 in a Donation Box Monitoring System for Detecting Potential Theft Galih Prasetyo; Yurni Oktarina; Abdurrahman
Journal of Electrical Engineering and Informatics (JEEI) Vol. 1 No. 3 (2026): OCTOBER (III)
Publisher : LPPM Sekolah Tinggi Teknologi Nusantara Lampung

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Donation boxes are widely used in mosques and other places of worship to collect funds for social and religious activities. Their accessible locations expose them to theft, while manual surveillance depends on personnel and cannot always be maintained continuously. This study presents a computer vision system for donation box security monitoring that deploys You Only Look Once version 8 (YOLOv8) on a Raspberry Pi 4. A webcam captures images for real-time detection of people and donation boxes. The system assigns four security categories, Safe, Suspicious, Highly Suspicious, and Danger, according to object presence, proximity, and duration. Suspicious activity triggers Telegram notifications accompanied by captured images. The model was trained for 55 epochs using an input image size of 640 × 640 pixels. The reported arithmetic means across the two classes were 70.5% for precision, 84.4% for recall, and 75.7% for the F1 score. System testing demonstrated detection of the defined security conditions and successful delivery of notifications. The implementation supports the feasibility of automated donation box monitoring and early warnings of potential theft under the tested conditions.
Physics-Guided Wind Power Forecasting Using SCADA Data and Seasonal Generalization Assessment Nambi Anansta; Putra Aditya Juwanda
Journal of Electrical Engineering and Informatics (JEEI) Vol. 1 No. 3 (2026): OCTOBER (III)
Publisher : LPPM Sekolah Tinggi Teknologi Nusantara Lampung

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

This study evaluates whether a physics-guided conversion prior improves very short-term wind power forecasting and seasonal generalization. Original open SCADA data from an 850 kW Vestas V52 in Ireland provide 254,336 credible ten-minute observations during 2013–2017. Models use 45 causal predictors, fitting on 2013–2015, selecting hyperparameters on 2016, and testing on 2017. A temperature-adjusted cubic conversion curve is combined with gradient-boosted wind and residual predictors and compared with matched direct learning, persistence, ridge regression, and indirect conversion baselines. Four additional experiments remove one season from supervised fitting and validation. At 10-, 30-, and 60-minute leads, the bounded physics-guided model attains RMSE of 54.68, 80.97, and 100.77 kW, respectively, compared with 53.03, 78.89, and 95.90 kW for bounded direct learning. Although the hybrid has slightly lower MAE at 30 and 60 minutes, paired seven-day bootstrap percentile ranges include no advantage over direct learning. Withholding winter increases hybrid RMSE by 10.11–20.17%, compared with 0.86–1.81% for the direct model. Raw hybrid outputs are negative in 11.24–15.78% of test cases, requiring explicit output bounds. Retrospective decomposition identifies substantial wind-to-power error propagation and conversion mismatch. The results establish the interpretive value of the physical prior while showing that it does not ensure superior accuracy or seasonal robustness for the examined turbine.
Probabilistic Net-Load Forecasting for Power Systems with Variable Solar and Wind Generation Sokip Anam; Nambi Anasta
Journal of Electrical Engineering and Informatics (JEEI) Vol. 1 No. 3 (2026): OCTOBER (III)
Publisher : LPPM Sekolah Tinggi Teknologi Nusantara Lampung

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Variable solar and wind generation changes both the level and the uncertainty of the residual demand that power-system operators must anticipate. This study evaluates probabilistic net-load forecasting using the original Open Power System Data hourly package for Germany over 2016–2019. A chronological design separates model fitting, validation, calibration, and a full 2019 test year. Forecasts for 1-, 6-, and 24-hour horizons use only completed-hour observations and known calendar information. Eight specifications compare empirical and Gaussian benchmarks, direct quantile gradient boosting, component forecasts with paired or independently resampled calibration errors, and static or rolling conformal quantile calibration. The independent component specification achieves the lowest weighted interval score among the primary specifications at every horizon: 0.430, 1.692, and 3.162 GW, respectively. Rolling calibration increases the direct model’s nominal 90% interval coverage from 86.3%, 75.7%, and 77.5% to 90.2%, 89.7%, and 88.9%, while improving its weighted interval score by only 0.44%, 4.80%, and 2.96%. Preserving calibration-period component dependence reduces residual variance by up to 21.3% but does not improve out-of-sample probabilistic scores relative to independent resampling. Coverage deteriorates during high renewable contribution and large realized ramps; at 24 hours, rolling-calibrated coverage falls to 63.3% for the latter subset. These findings support separating forecast accuracy, marginal calibration, and operational stress performance. The experiment establishes an observation-based benchmark rather than a weather-informed operational optimum, and it identifies component error drift and conditional tail reliability as priorities for subsequent forecasting and scheduling research.
Evaluating Class Imbalance Handling in Student Dropout Prediction Using Enrollment Information and First Semester Performance Riki Purnama; Hendra Apriawan
Journal of Electrical Engineering and Informatics (JEEI) Vol. 1 No. 3 (2026): OCTOBER (III)
Publisher : LPPM Sekolah Tinggi Teknologi Nusantara Lampung

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Class imbalance treatments can improve educational classification while changing the decisions and probabilities produced by a model. This retrospective study evaluates enrollment information and first semester performance in the original UCI dataset of 4,424 students, preserving Dropout, Enrolled, and Graduate as separate outcomes. Twenty configurations combine two predictor sets, five training treatments, and logistic regression or random forest. Development-only nested cross-validation selects the model, and 885 untouched records support paired bootstrap intervals and ten planned contrasts with Holm correction. Random undersampling with first semester logistic regression was selected and achieved macro-F1 64.82% (95% interval 61.71%–67.97%), accuracy 68.70%, and dropout recall 63.03%. Adding first semester features increased natural-frequency macro-F1 by 15.35 percentage points for logistic regression and 13.98 points for random forest. Class weighting improved macro-F1 for both classifiers after multiplicity adjustment, and random oversampling improved random forest. Gains primarily reflected better recognition of Enrolled students, accompanied by lower dropout recall. All balancing treatments increased multiclass Brier error within each classifier, although dropout-specific error did not uniformly increase. A resolved-outcome binary analysis showed small classification gains and inflated mean dropout probabilities under balancing. The results support evaluating treatments against class-specific objectives and probability reliability, rather than assuming that balancing necessarily improves dropout identification. Missing event timestamps prevent interpreting this benchmark as prospective prediction after semester one.
Uncertainty-Aware Short-Term Photovoltaic Power Forecasting with Cross-Plant Generalization Bambang Sutrisno; Faiq Nurraihan
Journal of Electrical Engineering and Informatics (JEEI) Vol. 1 No. 3 (2026): OCTOBER (III)
Publisher : LPPM Sekolah Tinggi Teknologi Nusantara Lampung

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Short-term photovoltaic forecasting supports operational planning only when point accuracy, predictive uncertainty, and transferability are evaluated together. This study investigates these requirements using the original Solar Power Generation Data repository, containing fifteen-minute records from two Indian photovoltaic plants over 15 May–17 June 2020. A data audit identifies incomplete inverter panels and a tenfold discrepancy in the recorded DC-to-AC ratio. Consequently, forecasts target normalized aggregate AC power exclusively at timestamps with all 22 inverter records. Histogram-based quantile gradient boosting is evaluated at 15-, 30-, and 60-minute horizons under a fixed chronological fit–validation–calibration–test design. Local models, bidirectional transfer without target-plant model fitting, source-calibrated intervals, and target-recalibrated intervals are distinguished explicitly. Across the six transfer experiments, the rearranged median forecast reduces mean absolute error by 5.4–32.3% relative to ordinary persistence, although ridge regression outperforms it in several comparisons. Uncalibrated nominal 90% transfer intervals attain only 79.6–87.0% empirical coverage. Source calibration raises coverage to 85.1–91.7%, while three days of target calibration yield 88.1–94.2%. Increased coverage can require materially wider intervals and does not consistently improve weighted interval scores. Paired day-block bootstrap intervals reveal that two transfer skill estimates remain compatible with no improvement over persistence. The evidence supports a practical distinction between transferring a forecasting function and transferring its uncertainty calibration. For industrial energy planning, the resulting framework offers a transparent assessment of forecast risk, while the short observation period, missing-record selection, and limited plant metadata preclude claims of universal transferability or realized economic savings.

Page 2 of 2 | Total Record : 15