cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
-
Editorial Address
-
Location
Kota banda aceh,
Aceh
INDONESIA
JURNAL TEKNIK SIPIL
ISSN : -     EISSN : -     DOI : -
Core Subject : Engineering,
Arjuna Subject : -
Articles 6 Documents
Search results for , issue "Vol 3, No 1 (2014)" : 6 Documents clear
IDENTIFIKASI PENYEBAB TIMBULNYA PENGAJUAN KLAIM KONSTRUKSI DARI PENYEDIA JASA KE PENGGUNA JASA DI BANDA ACEH Keumala Hayati
Jurnal Teknik Sipil Vol 3, No 1 (2014)
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

ABSTRAK Penelitian ini bertujuan untuk menganalisis dan menilai pengaruh faktor-faktor penyebab timbulnya klaim konstruksi dari penyedia jasa ke pengguna jasa. Ruang lingkup penelitian ini dibatasi pada perusahaan penyedia jasa dengan kualifikasi perusahaan gred 3, gred 4, gred 5, grade 6 dan gred 7 di Banda Aceh. Sampel dalam penelitian ini sebanyak 40 penyedia jasa yang berdomisili di Banda Aceh. Dalam penelitian ini, data-data yang diperoleh berupa data hasil dari pengisian kuisioner. Selanjutnya data hasil kuisioner diolah dengan teknik statistik yaitu mean, reliabilitas, korelasi, regresi linear berganda, determinasi dan uji f. Dari hasil penyebaran kuisioner diperoleh mean tertinggi terdapat pada variabel perubahan jadwal sebesar 3,29, dan mean terendah sebesar 2,79 terdapat pada variabel kondisi lapangan. Analisis reliabilitas menunjukkan semua nilai variabel memenuhi persyaratan cronbach alpha yaitu lebih besar dari 0,6. Nilai yang diperoleh dari analisis korelasi yaitu sebesar 0,798, nilai ini menunjukkan hubungan tinggi atau kuat. Analisis regresi linear berganda diperoleh model Y= 4,620 + 0,182X1 + 0,165X2 + 0,220X3 + 0,186X4 - 0,111X5 + 0,253X6. Faktor yang paling berpengaruh dari penyebab klaim adalah pada X6 yaitu konflik dalam rancangan dan spesifikasi. Koefisien determinasi diperoleh nilai sebesar 0,636 atau 63,6% dan untuk uji f diperoleh nilai F statistik sebesar 9,612 lebih besar dari nilai F tabel sebesar 2,39. Kata kunci : klaim, penyedia jasa, pengguna jasa, konstruksi  
PENGARUH PENGGUNAAN SENGKANG DIAMOND DENGAN JARAK 100 MM TERHADAP KAPASITAS AKSIAL KOLOM BETON BERTULANG Wahyuni Wahyuni
Jurnal Teknik Sipil Vol 3, No 1 (2014)
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

ABSTRAK Sebagai elemen struktur yang dominan menerima beban tekan aksial, maka kolom sangat menentukan kekuatan dari suatu konstruksi bangunan. Secara umum perilaku kehancuran kolom yang terjadi akibat beban aksial. Tulangan lateral atau sengkang sangat diperlukan untuk mencegah terkelupasnya (spalling) penutup beton dan terjadinya tekuk lokal (local buckling) pada batang-batang longitudinal akibat beban aksial, sehingga sengkang sangat efektif untuk meningkatkan kekuatan dan memperlambat proses keruntuhan kolom beton terkekang agar menjadi lebih dektail. Penelitian ini bertujuan untuk mengetahui perbandingan kuat tekan aksial kolom beton bertulang dengan kombinasi sengkang tertutup dan sengkang diamond. Benda uji yang digunakan untuk perbandingan yaitu benda uji kolom beton polos sebanyak 3 (tiga) unit, benda uji kolom beton bertulang yang menggunakan sengkang normal sebanyak 3 (tiga) unit dan benda uji kolom beton bertulang yang menggunakan sengkang tambahan dalam bentuk diamond sebanyak 3 (tiga) unit. Semua benda uji direncanakan dengan penampang persegi ukuran 100 mm x 100 mm dan tinggi 300 mm. Untuk tulangan longitudinal digunakan tulangan 8D8 mm dengan tegangan leleh (fy) 298,57 MPa dan tulangan sengkang Ø5,8 mm dengan tegangan leleh (fy) 378,68 MPa dengan jarak sengakang 100 mm. Hasil pengujian memperlihatkan bahwa benda uji kolom dengan penambahan sengkang exstra diamond (B3) dapat menerima kuat tekan aksial yang lebih besar dibandingkan dengan benda uji kolom yang lainnya. Nilai kuat tekan yang diterima benda uji kolom B1 sebesar 190 kN, benda uji kolom B2 sebesar 246,67 MPa dan benda uji kolom B3 sebesar 260 kN. Dari hasil perhitungan persentase nilai kuat tekan yang diterima benda uji kolom B1 sebesar 27,27 %, sedangkan untuk benda uji kolom B2 mengalami peningkatan nilai kuat tekan sebesar 35,41 % dan untuk benda uji kolom B3 mengalami peningkatan sebesar 37,32 %. Kata Kunci : Sengkang Diamond, Kuat Tekan Aksial, Beton Bertulang.
MODEL FISIK PENELUSURAN PELIMPAH BENDUNGAN BENER Akmal Akmal
Jurnal Teknik Sipil Vol 3, No 1 (2014)
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

ABSTRAK Bendungan Bener ini akan dibangun di Kabupaten Purworejo, Provinsi Jawa Tengah. bendungan ini difungsikan untuk keperluan irigasi, penyediaan air baku dan pembangkit listrik tenaga air (PLTA). Adapun pertimbangan pembuatan bendungan baru ini dicanangkan oleh Balai Besar Wilayah Sungai Serayu-Opak.Penelitian ini bertujuan untuk mengetahui kinerja hidraulik bangunan pelimpah (Spillway) sehingga mendapatkan gambaran mengenai keamanan hidraulik bendungan tersebut. Simulasi model ini dilakukan dengan banjir berbagai kala ulang, dan diharapkan banjir tersebut tidak melimpas dari badan bendungan. Secara keseluruhan simulasi model ini masih perlu dievaluasi untuk mengetahui apakah terdapat fenomena hidraulika lain yang terjadiDengan dibuatnya model fisik ini diharapkan untuk mendapatkan gambaran yang lebih jelas mengenai perilaku hidraulik serta fungsi spillway sebagai suatu kesatuan bagian dari Bendungan Bener. Dari hasil penelitian, didapat bahwa spillway berfungsi dengan baik didalam mengalirkan air dari hulu ke hilir dan tidak meluap ke tubuh bendungan. Adapun hasil yang didapat dari simulasi model bendungan bila dibandingkan dengan hasil model matematis atau teori tidak terlalu berbeda jauh. Kata kunci: Simulasi, Model Fisik, dan Spillway
ANALISIS KEKUATAN DAN DAYA DUKUNG TANAH LEMPUNG YANG DISTABILISASI ASPAL EMULSI YUs Yudhiantoro
Jurnal Teknik Sipil Vol 3, No 1 (2014)
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

ABSTRAK  Soil is not always suitable be a place to build a construction or be a raw material construction because the most of soil have limited strength and bearing capacity. One of cause is volume changes; generally happened because there are swelling and shrinkage of clay soil together with drying and wetting in natural process automatically in a whole year. This study aims to determine the effect of Cationic Asphalt Emulsion, also called Asphalt Emulsion (AE),in strength and CBR (California Bearing Ratio) of clay soil. The disturbed of clay soil obtained from Desa Doy, Kecamatan UleeKareng, Banda Aceh and AE derived from PT. Hutama Prima, Cilacap, Jawa Tengah. Tests conducted by ASTM (American Standard Testing and Materials) which includes testing of compaction (Standard Proctor method)and CBR laboratory. The results showed that stabilization of optimum AE increase compression strength (qumaks) and CBR value, both of soaked and unsoaked. Value of optimum AE for maximum dry density is 7-10%, for compressive strength at optimum Proctor condition is 4-6% and for CBR value 2-3% (soaked) and 8-9% (unsoaked) at optimum Proctorcondition. Kata kunci : asphalt emulsion, compressive strength, CBR value, stabilization
PERBANDINGAN NILAI KUAT TEKAN TERHADAP PERBEDAAN METODE MIX DESIGN PADA CAMPURAN BETON NORMAL (Metode ACI (American Concrete Institute) 211.1 dan Road Note No.4) Keumala Citra Sarina Zein
Jurnal Teknik Sipil Vol 3, No 1 (2014)
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

ABSTRAK Penelitian ini bertujuan untuk membandingkan variasi mix design campuran beton terhadap kuat tekan beton normal dengan menggunakan metode  American Concrete Institute (ACI) dan Road Note No. 4 yang dilakukan umur perawatan beton dengan menggunakan Faktor Air Semen (FAS) 0,48. Hasil penelitian menunjukan bahwa langkah mix design dengan metode Road Note No. 4 lebih singkat dari pada ACI, dari segi komposisi material yang digunakan,  metode Road Note No. 4 lebih hemat dan ekonomis dari pada ACI. Pada proses pengujian kuat tekan menunjukan bahwa hasil kuat tekan beton normal dengan menggunakan metode Road Note No. 4 lebih baik dari pada Metode ACI. Hal ini menunjukan bahwa kekuatan tekan beton normal sangat dipengaruhi oleh metode campuran beton. Perbandingan dari hasil pengujian antara metode ACI dengan metode Road Note No. 4 pada umur beton 7 hari adalah 125,69 kg/cm² berbanding 169,851  kg/cm², terjadi kenaikan 26% pada metode Road Note No. 4. Untuk umur beton 14 hari adalah 156,641kg/cm² berbanding 184,949 kg/cm² terjadi kenaikan 15,31% pada metode Road Note No. 4 dan untuk umur beton 28 hari adalah 190,611 kg/cm²  berbanding 230,243kg/cm² dengan kenaikan 82,78%. Kata Kunci : Beton Normal, Metode ACI, Metode Road Note No. 4, dan Faktor Umur
ANALISIS FAKTOR-FAKTOR YANG MEMPENGARUHI MENINGKATNYA PERMINTAAN KONSUMEN TERHADAP PERUMAHAN VILLA CITRA DAN BUMI PERMATA - ACEH Hafnidar Abdul Rani
Jurnal Teknik Sipil Vol 3, No 1 (2014)
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

ABSTRAKRumah pada hakikatnya merupakan kebutuhan dasar (basic needs) manusia selain sandang, pangan, pendidikan dan kesehatan. Kebutuhan fisik berupa rumah atau tempat tinggal merupakan salah satu motivasi untuk pengembangan kehidupan yang lebih tinggi lagi, maka dengan kata lain bahwa tempat tinggal pada dasarnya merupakan wadah bagi manusia atau keluarga dalam melangsungkan kehidupannya. Peran tempat tinggal bagi kelangsungan hidup yang dinamis sangat mutlak karena tempat tinggal bukan sekedar tempat bernaung, namun merupakan tempat untuk melindungi diri dari kondisi alam. Faktor-faktor yang dianalisa pada penelitian ini adalah faktor lokasi, pertumbuhan penduduk, pendapatan konsumen, kemudahan mendapatkan pinjaman, fasilitas dan sarana umum, harga pasar rumah dan undang-undang. Penelitian ini bertujuan untuk mengetahui aspek-aspek yang mempengaruhi meningkatnya permintaan konsumen terhadap perumahan Villa Citra dan Bumi Permata. Dalam penelitian ini, metode pemilihan sampel menggunakan teknik random sampling. Data tersebut dianalisis dengan analisis reliabilitas, korelasi dan regresi linier berganda dengan software SPSS. Hasil analisis reliabilitas diperoleh aspek meningkatnya permintaan konsumen terhadap perumahan (X) sebesar 0,819 dan keputusan pembelian rumah (Y) sebesar 0,916, menunjukkan sangat reliable. Dari hasil analisis korelasi didapat bahwa aspek pendapatan konsumen (X3), aspek harga pasar rumah (X6), dan aspek undang-undang (X7) bernilai signifikan dan berkorelasi positif. Korelasi terkuat yaitu hubungan antara aspek pendapatan konsumen dan keputusan pembelian rumah, yaitu r =0,782; p 0,01. Hasil analisis regresi linier berganda didapat faktor-faktor yang mempengaruhi meningkatnya permintaan konsumen terhadap perumahan adalah faktor/aspek pendapatan konsumen (X3) fasilitas dan sarana umum (X5), dan aspek harga pasar rumah (X6), dengan besarnya pengaruh adalah 71,6%, sedangkan sisanya 28,4% dipengaruhi oleh faktor-faktor lainnya. Dengan demikian konsumen dapat menentukan pembelian rumah karena pendapatannya yang mencukupi,  tersedianya fasilitas dan sarana umum, serta harga rumah yang terjangkau. Kata Kunci : Perumahan, pendapatan konsumen, fasilitas dan sarana umum, harga pasar.

Page 1 of 1 | Total Record : 6