Jurnal Fisika Unand
Published by Universitas Andalas
ISSN : 23028491     EISSN : 26862433     DOI : https://doi.org/10.25077/jfu
Makalah yang dapat dipublikasikan dalam jurnal ini adalah makalah dalam bidang Fisika meliputi Fisika Atmosfir, Fisika Bumi, Fisika Intrumentasi, Fisika Material, Fisika Nuklir, Fisika Radiasi, Fisika Komputasi, Fisika Teori, Biofisika, ataupun bidang lain yang masih ada kaitannya dengan ilmu fisika.
Articles 40 Documents
Search results for , issue "Vol 10 No 2 (2021)" : 40 Documents clear
Identifikasi Pencemaran Logam Berat pada Sedimen Sungai Batang Arau Kota Padang Berdasarkan Nilai Suseptibilitas Magnetik Ridha Putri Yanti; Afdal Afdal
Jurnal Fisika Unand Vol 10 No 2 (2021)
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (665.012 KB) | DOI: 10.25077/jfu.10.2.248-254.2021

Abstract

Telah dilakukan identifikasi pencemaran logam berat pada sedimen Sungai Batang Arau Kota Padang berdasarkan nilai suseptibilitas magnetik. Pengambilan sampel dilakukan mulai dari hulu hingga hilir pada 20 titik dengan kedalaman 10 cm. Hasil pengukuran menunjukkan nilai suseptibilitas magnetik  berkisar antara 116,6×10-8 kg-1m3 sampai 914,0×10-8 kg-1m3. Pola χFD (%) pada scattergram menunjukkan bahwa hampir seluruh sampel memiliki nilai χFD (%) < 5%. Hal ini menunjukkan ukuran bulir di lokasi penelitian yaitu bulir non-SP campuran halus dan kasar yang banyak dihasilkan dari proses-proses pencemaran. Berdasarkan nilai suseptibilitas magnetik  dan pola χFD (%) pada scattergram daerah penelitian telah mengalami pencemaran dari kategori tercemar rendah hingga tercemar sangat tinggi. Sedimen yang terletak di zona perumahan padat penduduk di kawasan tengah sungai cenderung memiliki nilai suseptibilitas yang lebih tinggi daripada di zona perumahan non-padat penduduk di kawasan hulu. Dapat dikatakan sumber dari pencemaran ini adalah sumber antropogenik.  Identification of heavy metal pollution in the sediments of the Batang Arau River, Padang City based on the magnetic susceptibility value has been carried out. Sampling was collected from upstream to downstream at 20 points with 10 cm depth. The results shows that magnetic susceptibility values range from 116.6× 10-8 kg-1m3 to 914.0 × 10-8 kg-1m3. The pattern of χFD (%) in the scattergram shows that almost all samples have a value of χFD (%) <5%. This shows the grain size in the research location, namely the fine and coarse mixture of non-SP grains which are mostly produced from pollution processes. Based on the magnetic susceptibility value and the χFD(%) pattern  in the scattergram, the research area has experienced pollution from low to very high polluted categories. Sediments located in densely populated residential zones in the midstream area  to have a higher susceptibility value than in non-densely populated residential zones in the upstream area. It can be said that the source of this pollution is an anthropogenic source.
Verifikasi Dosis Radiasi Teknik Penyinaran 3D-CRT pada Pasien Kanker Payudara Menggunakan Film EBT3 di Rumah Sakit UNAND Andrea Wessha; Dian Milvita; Muhammad Ilyas
Jurnal Fisika Unand Vol 10 No 2 (2021)
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1347.516 KB) | DOI: 10.25077/jfu.10.2.184-190.2021

Abstract

Verifikasi dosis radiasi teknik penyinaran Three-Dimensional Conformal Radiation Therapy  (3D-CRT) pada pasien kanker payudara telah dilakukan menggunakan film EBT3. Verifikasi dosis radiasi dilakukan di Rumah Sakit Universitas Andalas selama Agustus sampai September 2020. Pengukuran dosis radiasi menggunakan film EBT3 dilakukan untuk memverifikasi dosis radiasi terukur dengan Treatment Planning System (TPS) berdasarkan protokol International Atomic Energy Agency (IAEA) Technical Report Series (TRS) 398. Nilai dosis radiasi terukur diamati pada setiap lapangan penyinaran yaitu chest-wall dan supraclave. Verifikasi dosis radiasi dari penyinaran dosis radiasi yang terukur menggunakan film EBT3 mendapatkan nilai dosis radiasi yang lebih tinggi dari dosis radiasi TPS. Nilai dari pengukuran dosis radiasi menunjukkan dosis radiasi terukur pada lapangan penyinaran chest-wall cenderung tinggi jika dibandingkan dengan dosis radiasi terukur pada lapangan penyinaran supraclave. Hasil pengukuran dosis radiasi yang tinggi pada lapangan penyinaran chest-wall disebabkan adanya penggunaan bolus. Berdasarkan hasil pengukuran dosis radiasi tersebut verifikasi dosis radiasi berdasarkan TRS 398 tidak terpenuhi. Diskrepansi dosis radiasi terukur pada setiap pengukuran melebihi standar toleransi TRS 398 yaitu (0-5)% Dose verification of Three-Dimensional Conformal Radiation Therapy (3D-CRT) for breast cancer patient has been conducted using film EBT3. The dose radiation had been verificated in Andalas University Hospital from August to September in 2020. Dose radiation measurement using film EBT3 has been verified the dose radiation of Treatment Planning System (TPS) based on International Atomic Energy Agency (IAEA) Technical Report Series (TRS) 398. The measurable of dose radiation has been observed for chest-wall and supraclave. It was shown that the value of measurable dose radiation is higher than dose radiation in the TPS. The value of dose radiation measurement between chest-wall and supraclave showed different pattern. Measurable dose radiation on Chest-wall is tend to higher value than on supraclave. This pattern is may be due to that radiation treatment on chest-wall was using bolus. Furthermore, the dose radiation discrepancy using film EBT3 exceed the standard limitation base on TRS 398. Thus, the dose verification using film EBT3 is not properly enough for breast cancer patient.
Sistem Monitoring dan Notifikasi Penggunaan Air PDAM Berbasis Arduino dan Telegram Jihan Novelliani; Wildian Wildian
Jurnal Fisika Unand Vol 10 No 2 (2021)
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (608.408 KB) | DOI: 10.25077/jfu.10.2.219-224.2021

Abstract

Telah dirancang sebuah perangkat sistem monitoring dan notifikasi penggunaan air PDAM digital menggunakan sensor water flow. Sensor water flow digunakan untuk mengukur debit air dan power bank sebagai sumber tegangan dengan tegangan input untuk alat yaitu 5V. Pengolahan data dilakukan dengan menggunakan mikrokontroler Arduino Uno yang menampilkan hasil pengukuran di layar LCD serta berupa notifikasi di aplikasi telegram dengan modul ethernet shield sebagai media transmisi data. Alat yang dihasilkan mampu menampilkan jumlah penggunaan debit air dan biaya penggunaan air secara real time yang dapat diakses dengan menggunakan aplikasi telegram. Pengujian dilakukan dengan memvariasikan volume air dari 1 L sampai 5 L dengan selisih 0,5 L untuk setiap pengujian, Hasil pengujian menunjukkan perangkat sudah dapat bekerja dengan baik. Persentase kesalahan rata-rata sebesar 4.38 % terhadap alat pembanding yaitu gelas ukur. A system of monitoring and notification of digital PDAM water using a water flow sensor has been designed. The water flow sensor is used to measure the water debit and power bank as a voltage source with the input voltage for the device called 5V. Data processing is carried out using an Arduino Uno microcontroller which displays the measurement results on the LCD screen as well as a notification in the telegram application with the ethernet shield module as a data transmission medium. The resulting tool's able to display the amount of water discharge usage and water usage fees in real time which can be accessed using the telegram application. The test is carried out by varying the volume of water from 1 L to 5 L with a difference of 0.5 L for each test. The test results show that the device is working properly. The average error percentage is 4.38% for the comparison tool, namely the measuring cup. 
Ekstrak Kulit Batang Bakau sebagai Inhibitor Korosi Baja Komersil Tantri Marelita Aini; Dahyunir Dahlan
Jurnal Fisika Unand Vol 10 No 2 (2021)
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1255.177 KB) | DOI: 10.25077/jfu.10.2.156-162.2021

Abstract

Telah dilakukan penelitian tentang pengaruh ekstrak kulit batang bakau sebagai inhibitor korosi baja komersil.  Dalam penelitian ini dibentuk lapisan pada permukaan baja menggunakan metode elektrodeposisi.  Lapisan dibuat dari pelarutan Nikel (II) sulfat 1M, asam borat 0,24 M dan aquades dengan tambahan ekstrak kulit batang bakau pada konsentrasi 0%; 0,5%; 1%; 1,5%; 2% dan 2,5% volume.  Baja terkorosi dalam larutan NaOH 1 M selama 4,5 jam. Karakterisasi menggunakan mikroskop optik untuk semua sampel dan karakterisasi X-Ray Diffractometer (XRD) untuk sampel terbaik yaitu sampel yang telah dielektrodeposisi dengan konsentrasi inhibitor 2% sebelum dan sesudah korosi.  Laju korosi diukur menggunakan metode kehilangan berat, dimana kehilangan berat baja berbanding lurus dengan laju korosi.  Penambahan konsentrasi ekstrak kulit batang bakau dapat mengurangi kehilangan berat pada baja dan meningkatkan efisiensi inhibisi.  Efisiensi inhibisi paling besar yaitu 83% dengan penambahan 2% dan 2,5% inhibitor.  Karakterisasi menggunakan mikroskop optik menunjukkan baja dengan konsentrasi 2% adalah yang paling optimum karena tidak tergerus, tidak terbentuk endapan korosi dan permukaannya masih dalam keadaan halus setelah direndam dalam media korosif.Research on the effect of mangrove stem bark extract as an inhibitor of commercial steel corrosion has been conducted. This research produces a coating on the steel surface using the electrodeposition method. The coating was made from dissolving 1M nickel (II) sulfate, 0.24 M boric acid and distilled water with the addition of mangrove bark extract at a concentration of 0%; 0.5%; 1%; 1.5%; 2% and 2.5% by volume. Steel was electrodeposed for 3 minutes with a voltage of 3V. The steel corroded in 1 M NaOH solution for 4.5 hours. Characterization using an optical microscope for all samples and characterization of the X-Ray Diffractometer (XRD) for the best sample, namely samples that have been electrodeposed with 2% inhibitor concentration before and after corrosion. The corrosion rate was measured using the weight loss method, where the weight loss of steel is directly proportional to the corrosion rate. Increasing the concentration of mangrove bark extract can reduce weight loss in steel and increase inhibition efficiency. The greatest inhibition efficiency was 83% with the addition of 2% inhibitor. Characterization using an optical microscope shows that steel with a concentration of 2% is the most optimum because it is not eroded, no corrosion deposits are formed and the surface is still in a smooth state after immersing in corrosive media.
Rancang Bangun Sensor Serat Optik dengan Cladding Zinc Oxide untuk Mendeteksi Kelembaban Udara Miskhatul Hidayati; Harmadi Harmadi
Jurnal Fisika Unand Vol 10 No 2 (2021)
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (578.602 KB) | DOI: 10.25077/jfu.10.2.255-261.2021

Abstract

Telah dilakukan rancang bangun sensor serat optik dengan cladding zinc oxide untuk mendeteksi kelembaban udara. Sistem sensor serat optik dilakukan dengan metode pengupasan cladding yang diganti dengan Zinc Oxide (ZnO) dengan variasi pengupasan 1 cm, 2 cm, 3 cm, 4 cm, dan 5 cm. Sistem sensor terdiri dari dioda laser  sebagai sumber cahaya, serat optik cladding ZnO sebagai pengindra kelembaban, dan sensor OPT101 sebagai fotodetektor, mikrokontroler sebagai pengolah sinyal serta nilai kelembaban udara ditampilkan melalui PC (personal computer). Kelembaban diukur berdasarkan perubahan tegangan keluaran, semakin tinggi kelembaban udara maka semakin tinggi tegangan keluaran sensor. Hasil karakterisasi sensor menunjukkan serat optik dengan panjang pengupasan 2 cm adalah yang paling optimum dalam mengindra kelembaban. Nilai sensitifitas sensor yang dirancang adalah 0,0313 V/%RH dengan koefisien determinasi R2 = 0,9684. Sensor serat optik dengan cladding ZnO mampu mendeteksi kelembaban udara dalam rentang 88% RH s/d 99% RH dengan persentase rata-rata error pada alat ukur yang dirancang adalah 0,75% dibandingkan dengan alat ukur higrometer. A fiber optic sensor design with zinc oxide cladding has been designed to detect air humidity. The fiber optic sensor system was carried out by using the cladding stripping method which was replaced with Zinc Oxide (ZnO) with a stripping variation of 1 cm, 2 cm, 3 cm, 4 cm, and 5 cm. The sensor system consists of a laser diode as a light source, a fiber optic cladding ZnO as a moisture sensor, and an OPT101 sensor as a photodetector, a microcontroller as a signal processor and air humidity values and displayed via a PC (personal computer). Humidity is measured based on changes in the output voltage, the higher the humidity of the air, the higher the sensor output voltage. The results of sensor characterization showed that the optical fiber with a stripping length of 2 cm was the most optimum for sensing moisture. The designed sensor sensitivity value is 0.0313 V/%RH with a coefficient of determination R2 = 0.9684. The fiber optic sensor with ZnO cladding is able to detect air humidity in the range of 88% to 99% with an average error percentage of the designed measuring instrument is 0.75% compared to a hygrometer measuring instrument
Suseptibilitas Magnetik Tanah Sebagai Indikator Bencana Longsor Daerah Sitinjau Lauik Alvan Dhani; Afdal Afdal; Arif Budiman
Jurnal Fisika Unand Vol 10 No 2 (2021)
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (697.282 KB) | DOI: 10.25077/jfu.10.2.191-197.2021

Abstract

Pengukuran nilai suseptibilitas magnetik tanah untuk memprediksi longsor pada daerah Sitinjau Lauik telah dilakukan menggunakan metoda kemagneta batuan .  Sampel tanah diambil berdasarkan daerah yang diduga belum terjadi longsor (L2 dan L3) dan daerah telah terjadi longsor (L1 dan L4) sebanyak empat daerah, sampel diambil dengan variasi kemiringan (atas, tengah, bawah) dan kedalaman 25, 50, dan 75 cm sebanyak 36 titik sampel.  Pengukuran suseptibilitas magnetik mengunakan alat Bartington Susceptibility Meter MS2B.  Pada daerah diduga belum terjadi longsor nilai χLF  rata-rata yaitu 405,9×10-8 m3kg-1, sedangkan pada daerah telah terjadi longsor nilai χLF  rata-rata yaitu 285,2 ×10-8 m3kg-1.  Hasil pengukuran nilai suseptibilitas magnetik menunjukkan bahwa tanah yang terkandung di daerah sitinjau lauik mengandung lempung, dengan ditemukannya mineral magnetik seperti illite, montmorillonite, dan hematit yang merupakan mineral penyusun dari lempung.  Daerah L3 lebih rentan terjadi longsor karena memiliki nilai χFD (%) berkisar (1,79-7,65)% dengan rata-rata 4,08 %, yang menunjukkan tanah pada L3 telah dipengaruhi oleh perubahan suhu dan cuaca yang akan menyebabkan sifat magnetik dari tanah tersebut melemah dan terjadilah pelapukan pada tanah sehingga memicu pergerakan tanah. Measurement of soil magnetic susceptibility to predict landslides in Sitinjau Lauik has been happened by using the rock magnetism method.  Sample were taken from four areas based on area that has not happened landslide (L2 and L3) and area where landslide had occurred (L1 and L4). Sample were taken with slope variation ( top, middle, and bottom) and depth of 25, 50, 75 cm for 36 samples.  The magnetic susceptibility measurement was performed with Bartington Susceptibility Meter MS2B.  The results of measuring the magnetic susceptibility value show that the soil contained in the lauik site contains clay, with the discovery of magnetic minerals such as illite, montmorillonite, and hematite which are the constituent minerals of clay. The L3 area is more prone to landslides because it has a value of χFD (%) ranging (1.79-7.65)% with an average of 4.08%, which indicates that the soil at L3 has been affected by changes in temperature and weather which will cause magnetic properties from the soil weakens and there is weathering of the soil, which triggers soil movement.
Sistem Telemetri Pendeteksi dan Identifikasi Lokasi Jatuh Lansia Berbasis Sensor Getar ADXL345 Elsa Refni; Wildian Wildian
Jurnal Fisika Unand Vol 10 No 2 (2021)
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (132.138 KB) | DOI: 10.25077/jfu.10.2.225-231.2021

Abstract

Lanjut usia memiliki keterbatasan fisik sehingga potensi jatuh yang dialami cukup tinggi. Ketika lansia jatuh dan tidak segera mendapat pertolongan dalam jangka waktu yang cukup lama dapat mengakibatkan cacat, lumpuh hingga kematian. Penanggulangan hal ini dapat dilakukan dengan melakukan pengawasan sehingga lansia yang mengalami jatuh segera mendapat pertolongan. Pengawasan secara tidak langsung dapat dilakukan dengan memanfaatkan smartphone. Pada penelitian ini, besaran akselerasi pada sumbu x,y z dari sensor ADXL345 digunakan untuk mengetahui besarnya percepatan dari gerakan yang dihasilkan oleh objek. Saat sensor mendeteksi nilai akselerasi mencapai nilai ambang batas sebesar z ≤ -0,20 yang diperoleh melalui eksperimen maka Arduino Uno akan memproses informasi tersebut sehingga koordinat lokasi jatuh dapat dikirimkan melalui SMS menggunakan modul SIM900A. Hasil penelitian ini menunjukkan sistem memiliki keakuratan hingga 80%  Eldery is people who are more than 60 years old. Eldery have a physical limitation, so that eldery have the hight risk of slipping. When eldery person slips and doesn’t get help immediately get help for a long periode of time can lead to disability, paralysis to death. Overcoming this can be done by monitoring. This monitoring can help eldery get help immediately. Indirect surveilance can be done using a smartphone. On this research, amount of acceleration on x, y, z axis of ADXL345 sensor is used to determine the magnitude of acceleration of motion generated by the object. When the sensor detects the acceleration value reaches a threshold value of z ≤ -2,00 G which is obtained through eperiments, Arduino Uno will process the information so that the coordinates of the slips location indentified by GPS NEO-6M can be sent via SMS using the SIM900A module. The result of this research indicate the system has an accurancy of up to 80%.
Optimasi Filter Gelombang Mikro Berbasis Metamaterial Split Ring Resonators Disti Nabila Suci; Mulda Muldarisnur
Jurnal Fisika Unand Vol 10 No 2 (2021)
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1776.219 KB) | DOI: 10.25077/jfu.10.2.163-169.2021

Abstract

Optimasi geometri metamaterial Split Ring Resonators (SRR) dilakukan dengan menvariasikan ukuran geometrinya sehingga dapat bekerja pada rentang frekuensi gelombang mikro dan dapat diaplikasi sebagai filter gelombang mikro. Variasi dilakukan terhadap ukuran jari-jari SRR (r), lebar celah SRR (g), dan lebar cincin SRR (c). Optimasi bertujuan untuk mengetahui bagaimana pengaruh variasi geometri metamaterial  SRR terhadap bandwidth frekuensi, insertion loss dan frekuensi resonansi dari filter yang dihasilkan. Perancangan geometri SRR dan variasi geometri dilakukan secara numerik menggunakan software Comsol Multiphysics. Data bandwidth frekuensi, insertion loss dan frekuensi resonansi yang didapatkan dari Comsol Multiphysics diolah menggunakan Matlab. Luaran yang didapatkan dari Matlab adalah grafik yang menyatakan pengaruh variasi geometri metamaterial SRR terhadap bandwidth frekuensi, insertion loss dan frekuensi resonansi filter yang dihasilkan. Hasil yang didapatkan, semakin kecil lebar cincin maka semakin besar lebar bandwidth yang dihasilkan. Lebar celah cincin SRR tidak mempengaruhi bandwidth frekuensi. Semakin kecil jari-jari, lebar celah dan jarak pisah cincin luar dan cincin dalam maka insertion loss yang dihasilkan semakin kecil. Frekuensi resonansi yang didapatkan secara numerik lebih besar daripada frekuensi dengan perhitungan analitik. Perbedaan ini disebabkan karena posisi geometri SRR secara analitik berbeda dengan numerik.  Hasil optimal yang didapatkan dari optimasi ini adalah geometri dengan r = 6,5 mm, l = 0,75 mm, g = 2 mm yang memiliki bandwidth 690 MHz frekuensi dan insertion loss filter -4 dB.
Identifikasi Air Tanah di Daerah Pesisir Pantai Kolbano Yanti Boimau; Anastasia Kadek Dety Lestari
Jurnal Fisika Unand Vol 10 No 2 (2021)
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (808.923 KB) | DOI: 10.25077/jfu.10.2.262-266.2021

Abstract

Telah dilakukan penelitian identifikasi air tanah di wilayah pesisir Kolbano yang bertujuan untuk mengetahui dan menentukan kedalaman air tanah di lokasi penelitian. Metode yang digunakan adalah metode geolistrik dengan konfigurasi Schlumberger. Data yang diperoleh di lokasi penelitian diolah menggunakan software Res2dinv untuk mendapatkan nilai resistivitas batuan di lapangan. Hasil inversi menunjukkan nilai resistivitas batuan terukur pada 3 lintasan yaitu 17,1-27,626 Ωm. Berdasarkan nilai resistivitas yang diperoleh, diasumsikan terdapat 3 jenis lapisan batuan di lapangan, yaitu lempung dengan resistivitas (10-100) Ωm dan aluvium dengan resistivitas (101–800 Ωm) dan batugamping (101–27.626 Ωm). Potensi batuan sebagai batuan akuifer adalah alluvium. Air tanah yang tersimpan di batuan aluvium terletak pada kedalaman (12-20 m). Research on groundwater identification in the coastal area of Kolbano has been carried out, which aims to determine and determine the depth of groundwater at the research location. The method used is the geoelectric method with a Schlumberger configuration. The data obtained at the research location were processed using res2dinv software to obtain the rock resistivity value in the field. The inversion results show the measured rock resistivity value on 3 measurement line, namely 17.1-27.626 Ωm Based on the resistivity value obtained, it is assumed that there are 3 types of rock layers in the field, consisting of clay with resistivity (10-100 Ωm) and alluvium with resistivity (101-800 Ωm) and limestone (101-27.626Ωm). Rocks Potential as aquifer rocks is alluvium. Groundwater stored in alluvium rocks lies at a depth (12-20 m).
Rancang Bangun Sistem Telemetri Pemantauan Temperatur Tubuh Pasien Menggunakan Sensor DS18B20 dan Tranceiver nRF24L01+ Supindo Arrafat; Wildian Wildian
Jurnal Fisika Unand Vol 10 No 2 (2021)
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (663.185 KB) | DOI: 10.25077/jfu.10.2.198-204.2021

Abstract

Telah dilakukan perancangan sistem telemetri pemantauan temperatur tubuh menggunakan sensor DS18B20 dan transceiver nRF24L01+. Sistem ini dirancang dari beberapa unit yaitu sensor DS18B20 sebagai pengukur temperatur pada tubuh seseorang dan data temperatur tubuh tersebut dikirimkan melalui transceiver nRF24L01+ sebagai alat transmisi data. Karakterisasi sensor DS18B20 dilakukan dengan membandingkan dengan termometer digital. Jarak maksimum pengiriman data oleh transceiver nRF24L01+ adalah 400 m tanpa penghalang, 45 m dengan penghalang (antar ruangan) dan 18 m dengan penghalang (antar lantai). Alat ini memberitahukan kondisi “Normal” pada saat temperatur tubuh 36,5°C-37,5°C  dan “Tidak Normal” saat temperatur di atas 37,5°C dan di bawah 36,5°C. Temperatur yang terukur pada alat memiliki kesalahan rata-rata sebesar 0,741%.The design of a telemetry system for patient temperature monitoring has been carried out using a sensor DS18B20 and a transceiver nRF24L01+. This system is designed from several units, namely the sensor DS18B20 as a temperature measurement for a person's body and the transceiver nRF24L01+ as a data transmission tool to send the body temperature data.. Characterization of sensor DS18B20 is done by comparing it with a digital thermometer. The maximum distance for data transmission by the transceiver nRF24L01+ is 400 m without obstructions, 45 m with barriers (between rooms) and 18 m with barriers (between floors). The system informs the condition "Normal" when the body temperature is 36.5°C-37.5°C and "Abnormal" when the temperature is more or less than that body temperature. The temperature measured on the tool has an average error of 0.741%.

Page 1 of 4 | Total Record : 40