cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
-
Editorial Address
-
Location
Kota padang,
Sumatera barat
INDONESIA
Jurnal Dampak
Published by Universitas Andalas
ISSN : 25975129     EISSN : 18296084     DOI : -
Core Subject : Social, Engineering,
Jurnal Dampak merupakan publikasi bidang lingkungan hidup yang bersifat ilmiah, dapat berupa hasil penelitian, aplikasi teknologi tepat guna atau ide penyelesaian terhadap permasalahan lingkungan hidup yang ada. Naskah belum pernah dipublikasikan dalam media lain, atau naskah sedang dalam proses review dan/atau menunggu untuk diterbitkan di media lain.
Arjuna Subject : -
Articles 9 Documents
Search results for , issue "Vol 15, No 1 (2018)" : 9 Documents clear
Studi Perancangan Dan Pemanfaatan TPS 3R Untuk Sampah TPS (Tempat Pengolahan Sampah Rumah Tangga Dian Kasih; Irvan Indrawan; Lies Setyowati; Munir Tanjung; Isra Suryati
Jurnal Dampak Vol 15, No 1 (2018)
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25077/dampak.15.1.16-22.2018

Abstract

As the population increases, waste generation and composition will increase. Therefore, there is a need for planned and effective waste handling so that the problem of waste can be resolved in accordance with the 3R (Reuse, Reduce, and Recycle) concept. The aim of this research is to calculate the amount of waste generation and the composition of domestic waste produced by the residents of Medan Denai, and also devise the type of 3R Waste Treatment Plant for the District of Medan Denai. The method for measuring the generation and composition of waste are based on SNI 19-3964-1994, that is based on income level. Meanwhile, the typical planning of TPS 3R is obtained from the calculation of waste generation which is associated with the projection of population. The result showed that the average of household waste in the District of Medan Denai was 0.265 kg/person/day or 1.4 l/person/day. The composition of household waste generation in the District of Medan Denai is dominated by food waste 65.38 %. It is estimated that in 2026, the waste generation produced in the District of Medan Denai would reach about 41,593.7 kg/day. The economic potential that can be generated by using 3R concept is estimated reaching about Rp11,687,190 - Rp85,370,971 per day. Managing waste with 3R concept require a TPS with 1,488.24 m2 of area to process the household waste, with the estimated cost required to build the facility is Rp598,960,540 and the operational cost is Rp104,000,000 per month.
Studi Dinamika Kualitas Air Daerah Aliran Sungai Batang Arau di Propinsi Sumatera Barat Erniwati Erniwati
Jurnal Dampak Vol 15, No 1 (2018)
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25077/dampak.15.1.37-42.2018

Abstract

Batang Arau banyak mengalami polusi air, pencemaran air sungainya memberikan kerusakan DAS dan peningkatan sedimen. Ini mengakibatkan banyaknya masuk buangan limbah cair yang bersumber dari limbah penduk dan limbah industri. Batang Arau adalah salah satu sumber air baku terutama sumber air baku untuk kebutuhan sehari dan sekarang kualitasnya sudah sangat menurun. Tinjauan mutu kualitas air sesuai dengan kriteria pada Peraturan Pemerintah No.82 tahun 2001 tentang pengelolaan kualitas air dan pengendaliannya.  Metode yang dipakai dalam pengujian ini metode SNI mengenai parameter kualitas air dan standar methode untuk pemerisaan air dan air limbah, Apha washington DC serta beberapa alat untuk pengujian mutu, data sekunder sebagai pendukung data dan lokasi letak penelitian contoh uji. Tujuan penelitian ini adalah untuk menguji, meneliti dan evaluasi kualitas air di berbagai tempat di Sungai Batang Arau . Kualitas air sangat dipengaruhi pencemaran lingkungan daerah aliran sungai, oleh rumah potong hewan, kegiatan pertanian yang terletak di hulu, serta kegiatan industri karet yang terletak di bagian hilir sungai. Jumlah suspended solid jauh lebih tinggi di aliran sungai menurun. Itu adalah sekitar 144 mg/L di hilir dan hanya 74 mg/L di hulu lokasi. Konduktivitas daya hantar listrik adalah sekitar 114–189 Umhos/cm. The BOD dan COD nilai yang variabel sekitar 3,4-9,7 mg/L. Padatan Terlarut yang terkandung dalam air sungai Batang Arau juga akan mempengaruhi tingkat beban pencemaran dalam air yang dapat menyebabkan penurunan kualitas air sungai Batang Arau, nilai BOD berkisar 5,3 mg/L – 18,3 mg/L dan nilai COD 13,7 mg/L - 50,7 mg/L. Dalam air sungai Batang Arau padatan terlarut hulu bagian 112- 124 mg/L dan di hilir 118 –144 mg/L. DO adalah variabel di  hulu karena air dari berbagai anak sungai berkisar 4,8 – 7,3 mg/L. Kualitas air yang berubah – rubah (tercemar) disebabkan limbah cairan yang masuk ke aliran sungai. Berdasarkan fakta-fakta IPAL pengolahan air limbah tidak beroperasi pada kondisi yang optimal. Operasi rencana pengolahan air limbah yang efektif dan peraturan pembuang limbah cair sebelum lepas ke sungai diharapkan untuk memenuhi standar kualitas air nasional.  Pengolahan limbah cair dengan treatmen fisika, kimia dan biologi menjadikan kualitas air bagus.
Perencanaan Sistem Plambing Air Bersih Gedung Rusunawa Mahasiswa Universitas Andalas Komala, Puti Sri; Abuzar, Suarni Saidi; Dewi, Purnama Mentari
Jurnal Dampak Vol 15, No 1 (2018)
Publisher : Jurusan Teknik Lingkungan Fakultas Teknik Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25077/dampak.15.1.23-30.2018

Abstract

Design of water supply and fire protection system in a low income five storey apartment of Andalas University has been conducted based on Indonesian National Standard (SNI) regulation No.03-7065-2005, that the building which has more than 500 inhabitants or more than 1.500 visitors, should prepare plumbing system design. The University of Andalas Student Rental Building is a residential building of five floors. In this water supply plan the water source is supplied from the Unand’s water treatment plant. The water supply system uses a roof tank system with a combination of gravity flow and booster pump. The water supply tank consists of the bottom tank and the upper tank with capacities of 74 m3 dan 4,5 m3, respectively. The booster pump meets the critical pressure on the 3rd floor up to the 5th floor with 5,44 m head. Class II fire prevention systems use hydrant and sprinkler systems with automatic wet-type upright pipes. The distribution pipes use PVC pipes (1/2  - 1 1/4) inches, while the hydrants and sprinkler pipes use Black Steel (1-4) inch pipe.
Studi Penurunan Chemical Oxygen Demand (COD) Pada Air Limbah Domestik Buatan Menggunakan Biofilter Aerob Tercelup dengan Media Bioring Marieta Sarahrut Dayanti; Netti Herlina
Jurnal Dampak Vol 15, No 1 (2018)
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25077/dampak.15.1.31-36.2018

Abstract

The purpose of this research is to know the effect of debit variation on Chemical Oxygen Demand (COD) reduction efficiency in artificial domestic wastewater after being processed using aerobic biofilter reactor. The biofilter was maintained at continues flow and aerobic state. The debit variations used were 0.56 l/h for 72 hours retention time, 0.83 l / h for 48 hours retention time and 1.67 l/h for a 24 hour retentione time. Efficiency of COD decreased at 0.56 l/hr variation was 84%, at 0.83 l / h was 86% while at 1.67 l/h was 75%. The effluent of domestic wastewater treatment using aerobic biofilter with bio ring media has fulfilled the Minister of Environment and Forestry Regulation No. 68/2012 on Quality Standard of Domestic Wastewater.
Biosorpsi Kromium (Cr) Pada Limbah Cair Industri Elektroplating Menggunakan Biomassa Ragi Roti (Saccharomyces cerevisiae) Shinta Elystia; Resna Rauda Putri; Sri Rezeki Muria
Jurnal Dampak Vol 15, No 1 (2018)
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25077/dampak.15.1.1-6.2018

Abstract

Electroplating industry is one of the industries producing liquid waste containing heavy metals. Among the heavy metals contained in the liquid waste is Chromium (Cr) which has a high toxicity. One technology that can be applied to eliminate Cr metal in liquid waste is by the method Biosorption using biomass derived from yeast bread (Saccharomyces cerevisiae). This study aimed to study the ability of bread yeast biomass (saccharomyces cerevisiae) in removing Cr metal on variations in biosorbent weight of 0.25; 0.5 and 0.75 grams, mesh size 80; 100 and 140 and contact time 1; 2; 3 and 4 hours. The results showed that the highest Cr removing efficiency occurred at 0.75 g biosorbent weight at 80 mesh and 4 hours contact time with efficiency of 54.7%. The biosorption process indicates that the adsorption isotherm type obtained is Langmuir isotherms assumed that the layer formed is monolayer with R2 value of 0.8819. The SEM analysis results show the difference of the morphological shape on the sample surface before and after the biosorption process
Sebaran Nilai Daya Hantar Listrik dan Salinitas pada Sumur Gali di Pesisir Pantai Kecamatan Padang Barat Tivany Edwin; Rinda Andhita Regia; Fauzia Rahmi
Jurnal Dampak Vol 15, No 1 (2018)
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25077/dampak.15.1.43-50.2018

Abstract

This study aims to determine the distribution of electrical conductivity and salinity values in dug well water as an indication of sea water intrusion. The study was conducted on the coastal area of Padang Barat District with 30 sample points and variation of 0-500 m distance from shore to the land. Measurement of electical conductivity values is measured in the field using conductivity meter while for salinity by argentometric method to analyze chloride ions which are then converted to Knudsen Equation. The range of conductivity values is 163.4-5260,8 μS / cm while the salinity value is 0.303-0.564 ‰. The relation of electrical conductivity and salinity values shows a very strong correlation with a value of 0.9373. The relation of the electrical conductivity value with the distance from the shoreline and the depth of the well shows no correlation with values of 0.264 and 0.054. The salinity value with the distance from the shoreline and the depth of the well also showed no correlation with the values of 0.205 and 0.003. The comparison of measured values with groundwater classification known as 2 points is slightly brackish water as an indication of sea water intrusion found in Purus and Berok Nipah sub-districts.
Evaluasi Tingkat Kebisingan Kawasan Selatan Universitas Negeri Padang Vera Surtia Bachtiar; Reri Afrianita; Ary Zamzamy
Jurnal Dampak Vol 15, No 1 (2018)
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25077/dampak.15.1.7-15.2018

Abstract

This study aims to determine and evaluate the level of noise in the southern area of Universitas Negeri Padang (UNP) Kampus Air Tawar conducted at 23 points of measurement with 16 outside outdoor points and 7 indoor measurement points. Method of measurement under regulation of Indonesian government, KepMenLH Regulation no. 48 thn 1996 which regulate the noise level standard by using SLM (Sound Level Meter). The highest outdoor noise level occurs in front of GOR UNP (S16) at the time of L3 which is 80,91 dBA, while the highest indoor noise level when there was activity as well as no activity in the room was happened in lecture hall FBSS UNP (S7-interior) with value equal to 83, 99 dBA and 64.65 dBA. All points of a total of 16 outdoor and 7 indoor measurement points exceed the standard noise level threshold which is 55 dBA (+3 dB tolerance). However, from the questionnaire results most respondents just feel slightly disturbed by outdoor noise in the study area. The noise control that can be done such as cultivate number of natural vegetation such as heliconia sp, tea, acacia tree and pringgodani bamboo, also the installation of continuous wall from type of clear fiber that serves as building noise absorbers.
Perencanaan Sistem Plambing Air Bersih Gedung Rusunawa Mahasiswa Universitas Andalas Puti Sri Komala; Suarni Saidi Abuzar; Purnama Mentari Dewi
Jurnal Dampak Vol 15, No 1 (2018)
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25077/dampak.15.1.23-30.2018

Abstract

Design of water supply and fire protection system in a low income five storey apartment of Andalas University has been conducted based on Indonesian National Standard (SNI) regulation No.03-7065-2005, that the building which has more than 500 inhabitants or more than 1.500 visitors, should prepare plumbing system design. The University of Andalas Student Rental Building is a residential building of five floors. In this water supply plan the water source is supplied from the Unand’s water treatment plant. The water supply system uses a roof tank system with a combination of gravity flow and booster pump. The water supply tank consists of the bottom tank and the upper tank with capacities of 74 m3 dan 4,5 m3, respectively. The booster pump meets the critical pressure on the 3rd floor up to the 5th floor with 5,44 m head. Class II fire prevention systems use hydrant and sprinkler systems with automatic wet-type upright pipes. The distribution pipes use PVC pipes (1/2  - 1 1/4) inches, while the hydrants and sprinkler pipes use Black Steel (1-4) inch pipe.
Analisis Konsentrasi SO2 dan CO Menggunakan Model Gaussian Line Source Di Udara Ambien Ridwan Syahputra Samosir; Ivan Indrawan; Isra Suryati; Hendri Irwandi
Jurnal Dampak Vol 15, No 1 (2018)
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25077/dampak.15.1.51-59.2018

Abstract

Purpose of this study to analyze concentration of SO2 and CO at Tanjung Morawa Toll Gate and Amplas Toll Gate with Gaussian Line Source modeling. Based on the measurement of ambient roadside air quality at Tanjung Morawa Toll Gate and Amplas Toll Gate, CO and SO2 concentrations still meet the ambient air quality standard according to PP. 41 year 1999. The highest concentration of CO at Tanjung Morawa Toll Gate is 447,06 μg/m3 and at Amplas Toll Gate is 389,54 μg/m3 while The highest concentration of SO2 at Tanjung Morawa Toll Gate is 97,7 μg/m3 and at Amplas Toll Gate is 62.51 μg /m3. Based on the calculation using Gaussian Line Source model, the highest CO concentration at Tanjung Morawa Toll Gate is 263,16 μg/m3 and at Amplas Toll Gate is 258,16 μg/m3 while The highest concentration of SO2 at Tanjung Morawa Toll Gate is 1,64 μg /m3 and at Amplas Toll Gate is 1.32 μg/m3. validation test results with IOA, NMSE, FB, and Fa2, Gaussian Line Source model can be applied at Tanjung Morawa Toll Gate and Amplas Toll Gate for CO parameters. Meanwhile Gaussian Line Source model can not be applied for SO2 parameters at Tanjung Morawa Toll Gate and Toll Gate of Amplas.

Page 1 of 1 | Total Record : 9