Comparative finite element analysis of IIW linear stress extrapolation and haibach methods for structural hot-spot stress prediction in welded plate joints Regan Rahadian Pambudi; Richard Alexander
Journal of Welding Technology Vol 8, No 1 (2026): June
Publisher : Politeknik Negeri Lhokseumawe

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30811/jowt.v8i1.9504

Abstract

Accurate prediction of structural hot-spot stress (SHSS) is essential for evaluating welded joints. This study compares the International Institute of Welding (IIW) Linear Stress Extrapolation (LSE) and Haibach methods using finite element analysis performed with the open-source software CalculiX. Three weld geometry representations (no weld, chamfer, and fillet) and two mesh densities (fine and coarse) were investigated, resulting in six finite element models. Both SHSS methods were applied to evaluate stress prediction, mesh sensitivity, weld geometry effects, and computational performance. The IIW LSE method consistently predicted higher SHSS than the Haibach method, while mesh refinement produced variations below 4%. In contrast, weld geometry had a greater influence on SHSS prediction, with the chamfer model producing the highest stress. Fine meshes required approximately five to six times longer computational time than coarse meshes while providing only marginal improvements in SHSS prediction. Weld geometry representation was therefore found to have a greater influence on SHSS prediction than mesh density. The IIW LSE method is recommended for conservative structural assessment, whereas the Haibach method is suitable for preliminary engineering analyses requiring simpler post-processing.
Ambient-Temperature Sensitivity of Operating-Data Fouling-Resistance Indicators for an Air-Cooled Condenser in a Binary Geothermal Power Plant Richard Alexander; Agus Setyawan; Udi Harmoko
International Journal of Innovation in Mechanical Engineering and Advanced Materials Vol. 8 No. 3 (2026)
Publisher : Universitas Mercu Buana

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22441/ijimeam.v8i3.40219

Abstract

Air-cooled condensers (ACCs) reject heat directly to the atmosphere, so operating-data fouling indicators are read against a heat sink that moves continuously. This study quantifies how much of the calculated fouling resistance of an ACC serving a 41.75 MW binary geothermal unit is generated by ambient-temperature variation alone, with the physical surface condition held unchanged, and establishes how that component depends on whether cooling-air flow is measured or inferred. A zone-resolved thermal model was built from bundle geometry, plant working-fluid states and a measured fan air velocity of 6.02 m s⁻¹, with n-pentane and air properties taken from CoolProp. The indicator was evaluated over the observed ambient range of 18.63 to 29.56 °C under three routes that differ only in which air-side quantity is measured. Ambient variation alone moved the indicator by 2.22 × 10⁻² m² K W⁻¹ across the mean daily range, which exceeded its own mean value by a factor of 3.3 and reversed its sign at 24.5 °C although the surface condition did not change. The negative values carry no physical meaning, because a deposit cannot reduce thermal resistance. The sign of the reported trend followed the air-side assumption rather than the equipment, and four clean-condition treatments shifted the level of the indicator without altering its ambient slope, which stayed negative in 100 % of 2,000 Monte Carlo samples. The calculated resistance therefore measures the ambient sensitivity of the method and not the fouling state of the bundle. Matched-ambient comparison bands, a plant-specific clean baseline and independent air-side indicators are required before it can support a cleaning or maintenance decision.