Application of ground penetrating radar for evaluating foundation structure condition after earthquake Risma Apdeni; Zel Citra; Fitra Rifwan; Prima Yane Putri; Nevy Sandra; Yosie Malinda; Paksi Dwiyanto Wibowo; Reza Ferial Ashadi; Annisa Prita Melinda
Teknomekanik Vol. 7 No. 1 (2024): Regular Issue
Publisher : Universitas Negeri Padang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24036/teknomekanik.v7i1.26772

Abstract

At the time of seismic activity, the failure of the foundation structure will lead to building damage. When the West Pasaman 2022 earthquake occurred, PT. XYZ is constructing a feed mill tower. Since strong earthquake shocks were felt at the project location, foundation structure evaluation is needed to ensure the safety of the building. Ground Penetrating Radar (GPR) is a tool that is widely used to detect subsurface conditions. This study used GPR as a non-destructive testing technique to evaluate the condition of the foundation structure. The building evaluated is a high-rise steel building, using spun pile foundation. GPR test was carried out in specified lanes, with measurement tracks set at 10 lanes. Any cracks or fractures on the foundation will be indicated by the interruption of waves at the point of the crack or fracture. The GPR test results from readings of electromagnetic wave propagation showed that waves can reach the end of each foundation tested, ranging from 17.10 m to 17.82 m deep. It means that there are no cracks or fractures found on the slab, pile cap, or foundation. Analysis results showed that all slabs and pile caps thicknesses and the detected foundation piles depths are in accordance with the foundation design, which means that the foundations are still in good condition.
Development and preliminary evaluation of a storytelling-based instructional video for roof-truss construction in vocational education Laras Oktavia Andreas; Johandra Fakhriy Rahmadi; Fitra Rifwan; Windry Novalia Jufri
Jurnal Pendidikan Teknologi Kejuruan Vol 9 No 3 (2026): Regular Issue
Publisher : Universitas Negeri Padang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24036/jptk.v9i3.51623

Abstract

This study developed and preliminarily evaluated a storytelling-based instructional video for roof-truss construction in vocational education. Using the ADDIE framework, the video integrated a problem-centered narrative with three-dimensional modeling, animation, GIF-based visualization, voice-over narration, and synchronized multimedia elements. The study involved Grade XI Building Modeling and Information Design students at SMK Negeri 1 West Sumatra. Evaluation involved three subject-matter experts, three media experts, 19 students, and five teachers. Expert judgments were analyzed using Aiken's V, inter-rater consistency was summarized using Percentage Agreement, and practicality was assessed descriptively from teacher and student responses. The developed video obtained an overall Aiken's V of 0.94 for subject-matter validity and 0.95 for media-design validity. Pairwise expert ratings produced an average Percentage Agreement of 99.42%. During limited classroom implementation, students reported 91% practicality, while teachers reported 94%. These findings indicate that the instructional video met the predefined developmental criteria for expert-based validity, inter-rater agreement, and preliminary practicality. However, because the study did not include a control group, pretest–posttest comparison, or inferential learning-outcome analysis, the results do not establish instructional effectiveness. Further controlled studies are required to examine learning outcomes. Future research should directly examine conceptual understanding, spatial interpretation, technical reasoning, retention, and transfer.