Claim Missing Document
Check
Articles

Found 2 Documents
Search

Peran Elektromedis dalam Pengelolaan Teknis Peralatan Maternal-Neonatal untuk Menjamin Keselamatan dan Keandalan Alat Kesehatan di Puskesmas Kota Kediri Agoes Santika Hyperastuty; Dio Alif Pradana; Rahma Ajeng Puspitasari; Radian Indra Mukromin; Lailatul Inayah; Yanuar Mukhammad; Muhammad Yusron Al Aziz; Izzet Taqiyuddin Hakim; Selfanus Heksa Kurnianto
Jurnal Pengabdian Masyarakat Bhinneka Vol. 4 No. 4 (2026): Juli
Publisher : Bhinneka Publishing

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58266/jpmb.v4i4.1396

Abstract

Peralatan maternal-neonatal memiliki peran penting dalam mendukung pelayanan kesehatan ibu dan bayi di puskesmas. Alat kesehatan yang tidak terpelihara, tidak terkalibrasi, atau tidak terdokumentasi dengan baik dapat menimbulkan risiko kesalahan pengukuran, keterlambatan pelayanan, serta menurunkan mutu dan keselamatan pasien. Kegiatan pengabdian kepada masyarakat ini bertujuan untuk menggambarkan peran elektromedis dalam pengelolaan teknis peralatan maternal-neonatal di Puskesmas Kota Kediri. Metode yang digunakan adalah deskriptif kualitatif melalui tahapan koordinasi, identifikasi alat, inventarisasi, pemeriksaan kondisi fisik, pengecekan fungsi, pemeliharaan, kalibrasi, dokumentasi, pelabelan status kelaikan, dan pemberian rekomendasi tindak lanjut. Hasil kegiatan menunjukkan bahwa dari 41 unit alat yang diperiksa, sebanyak 38 unit atau 92,68% dinyatakan laik pakai, 1 unit atau 2,44% laik dengan catatan, dan 2 unit atau 4,88% tidak laik. Hasil kalibrasi dan uji fungsi menunjukkan bahwa fetal doppler dan sphygmomanometer 75% memenuhi parameter teknis yang diuji dan 25% laik dengan catatan. Kegiatan ini menunjukkan bahwa keterlibatan tenaga elektromedis berperan penting dalam memastikan alat kesehatan berada dalam kondisi aman, akurat, andal, dan siap digunakan. Pengelolaan teknis yang terencana dan berkelanjutan diperlukan untuk mendukung keselamatan pasien serta meningkatkan mutu pelayanan maternal-neonatal di puskesmas.
IoT-Based Tele-ECG Systems: A Systematic Review of Architecture, Signal Quality, and Transmission Reliability Rahma Ajeng Puspitasari; Dio Alif Pradana; Agoes Santika Hyperastuty
Jurnal Media Elektrik Vol. 23 No. 3 (2026): MEDIA ELEKTRIK
Publisher : Jurusan Pendidikan Teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.59562/metrik.v23i3.13930

Abstract

Objective: Cardiovascular disease remains the leading cause of death worldwide, and early arrhythmia detection through electrocardiography (ECG) is critical; however, access to conventional ECG equipment at primary healthcare facilities remains limited. Portable Internet of Things (IoT)-based tele-electrocardiography (tele-ECG) systems have been proposed to close this gap; however, evidence on their architecture, signal quality, and transmission reliability remains scattered, with no integrated synthesis available. This review maps IoT-based Tele-ECG architecture, signal quality methods, and transmission reliability challenges, identifying gaps relative to prior scoping reviews on wearable and home-use ECG devices. Method: A Systematic Literature Review was conducted following PRISMA, searching Scopus and IEEE Xplore on 9 July 2026. Three independent reviewers screened the records and assessed full-text eligibility, with study quality appraised using the Mixed Methods Appraisal Tool. From 55 initial records, 31 studies (2020–2026) met the full-text verified inclusion criteria. Results: Low-cost architectures were dominated by AD8232/AD823X/MAX30003 sensors paired with ESP32/ESP8266/ STM32/nRF-series microcontrollers (48.4% of studies), which transmitted data via Bluetooth Low Energy, Wi-Fi, or cloud platforms. Signal quality evaluation relies on Signal Quality Index metrics or deep learning classifiers (29.0%), while reported challenges span latency, packet loss, power consumption, and data security. Novelty: Unlike prior reviews addressing device technology or clinical validation separately, this review is the first to jointly synthesize architecture, signal quality, and transmission reliability evidence for IoT-based Tele-ECG systems, revealing that no study has evaluated all three dimensions within one integrated protocol under realistic, resource-limited network conditions, which is a gap with direct implications for future low-cost Tele-ECG system design and validation.