Claim Missing Document
Check
Articles

Found 2 Documents
Search

Peran Elektromedis dalam Pengelolaan Teknis Peralatan Maternal-Neonatal untuk Menjamin Keselamatan dan Keandalan Alat Kesehatan di Puskesmas Kota Kediri Agoes Santika Hyperastuty; Dio Alif Pradana; Rahma Ajeng Puspitasari; Radian Indra Mukromin; Lailatul Inayah; Yanuar Mukhammad; Muhammad Yusron Al Aziz; Izzet Taqiyuddin Hakim; Selfanus Heksa Kurnianto
Jurnal Pengabdian Masyarakat Bhinneka Vol. 4 No. 4 (2026): Juli
Publisher : Bhinneka Publishing

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58266/jpmb.v4i4.1396

Abstract

Peralatan maternal-neonatal memiliki peran penting dalam mendukung pelayanan kesehatan ibu dan bayi di puskesmas. Alat kesehatan yang tidak terpelihara, tidak terkalibrasi, atau tidak terdokumentasi dengan baik dapat menimbulkan risiko kesalahan pengukuran, keterlambatan pelayanan, serta menurunkan mutu dan keselamatan pasien. Kegiatan pengabdian kepada masyarakat ini bertujuan untuk menggambarkan peran elektromedis dalam pengelolaan teknis peralatan maternal-neonatal di Puskesmas Kota Kediri. Metode yang digunakan adalah deskriptif kualitatif melalui tahapan koordinasi, identifikasi alat, inventarisasi, pemeriksaan kondisi fisik, pengecekan fungsi, pemeliharaan, kalibrasi, dokumentasi, pelabelan status kelaikan, dan pemberian rekomendasi tindak lanjut. Hasil kegiatan menunjukkan bahwa dari 41 unit alat yang diperiksa, sebanyak 38 unit atau 92,68% dinyatakan laik pakai, 1 unit atau 2,44% laik dengan catatan, dan 2 unit atau 4,88% tidak laik. Hasil kalibrasi dan uji fungsi menunjukkan bahwa fetal doppler dan sphygmomanometer 75% memenuhi parameter teknis yang diuji dan 25% laik dengan catatan. Kegiatan ini menunjukkan bahwa keterlibatan tenaga elektromedis berperan penting dalam memastikan alat kesehatan berada dalam kondisi aman, akurat, andal, dan siap digunakan. Pengelolaan teknis yang terencana dan berkelanjutan diperlukan untuk mendukung keselamatan pasien serta meningkatkan mutu pelayanan maternal-neonatal di puskesmas.
Design and Evaluation of Automated Fluid-Transfer Suction Pump Based on Arduino for Thoracic Trauma Applications Fuad Afandi; Radian Indra Mukromin; Yanuar Mukhammad; Rahma Ajeng Puspitasari
G-Tech: Jurnal Teknologi Terapan Vol 10 No 1 (2026): G-Tech, Vol. 10 No. 1 January 2026
Publisher : Universitas Islam Raden Rahmat, Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.70609/g-tech.v10i1.8965

Abstract

Thoracic trauma frequently leads to the accumulation of air or fluid within the pleural cavity, compromising pulmonary expansion and requiring immediate evacuation through suction systems. Conventional suction pumps rely heavily on continuous manual monitoring to prevent container overflow, creating potential risks of backflow, contamination, or device malfunction. This study aims to design and evaluate an automated dual-container suction pump prototype capable of maintaining stable suction pressure while minimizing manual supervision during fluid evacuation. The proposed system employs an Arduino Uno microcontroller and integrates an MPX5700DP pressure sensor for suction monitoring, an E18-D80NK infrared sensor for full-container detection, a 12 V solenoid valve for automated flow diversion, a 25DA Solid State Relay (SSR) for safe power switching, and a buzzer alarm for emergency shutdown. Experimental results indicate that all electrical outputs remain within acceptable tolerance ranges (1.2–4.7%), and suction pressure is consistently maintained at 70 cmHg before and after system modification. The accuracy of infrared sensor achieved a detection accuracy of only 30%, highlighting its limited suitability for reliable medical fluid-level monitoring and underscoring the need for alternative sensing technologies in future implementations. Despite this limitation, the prototype demonstrates the feasibility of automated fluid-transfer control and provides a practical foundation for the development of safer and more reliable suction systems for thoracic trauma applications.