REKONSTRUKSI KARIWARI SETELAH TSUNAMI 2011: PELESTARIAN ARSITEKTUR VERNAKULAR PAPUA DI TELUK YOUTEFA JAYAPURA Salipu, Muhammad Amir; Nurmaningtyas, Anggia Riani; Utomo, Sugito; Amir, Auryn Lusda
Jurnal MEDIAN Arsitektur dan Planologi Vol 15 No 01 (2025): Jurnal Median
Publisher : Universitas Sains dan Teknologi Jayapura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58839/jmap.v15i01.1549

Abstract

Bencana tsunami besar yang melanda pesisir timur Jepang pada tanggal 11 Maret 2011 berdampak hingga ke wilayah pantai utara Papua, termasuk Teluk Youtefa, Kota Jayapura. Gelombang tsunami ini merusak banyak infrastruktur penting, seperti jalan jerambah dan bangunan adat Kariwari di Kampung Enggros, kawasan Teluk Youtefa. Tujuan penelitian ini adalah untuk mengevaluasi dampak tsunami Jepang tahun 2011, yang dianggap sebagai penyebab utama kerusakan struktur Kariwari di Teluk Youtefa, mempelajari kearifan lokal suku Enggros tentang standar spasial tradisional untuk penempatan Kariwari. dan menyarankan teknik rekonstruksi untuk struktur Kariwari yang tahan terhadap gelombang laut. Penelitian ini menggunakan pendekatan deskriptif kualitatif dan data diperoleh lewat observasi lapangan. Dampak gelombang tsunami terhadap kegagalan struktural Kariwari dinilai, bersama dengan pengetahuan tradisional masyarakat Enggros tentang tempat konstruksi yang aman. Penelitian ini menghasilkan tiga temuan penting, yaitu: resonansi tsunami meningkatkan ketinggian gelombang laut di Teluk Youtefa yang menghancurkan Kariwari; lokasi revitalisasi Kariwari yang dibangun pada tahun 2010 melanggar aturan spasial konvensional karena berada di paling luar jalur jerambah yang membuatnya rentan terhadap gelombang langsung; dan rekonstruksi yang disarankan adalah bangunan Kariwari ditempatkan kembali di tengah jalur jerambah, seperti yang dilakukan secara konvensional, dengan perkuatan pada tiang pondasi bangunan.
OPTIMASI OVERALL THERMAL TRANSFER VALUE (OTTV) PADA MASJID BAITURROHMAN DI JEMBER DENGAN PEMILIHAN KACA Auryn Lusida Amir; Indah Sari Zulfiana
Jurnal Teknologi Terpadu Vol 14 No 1 (2026): JTT (Jurnal Terpadu Terpadu)
Publisher : Pusat Penelitian dan Pengabdian Kepada Masyarakat

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32487/jtt.v14i1.3018

Abstract

The Overall Thermal Transfer Value (OTTV) is a parameter used to evaluate the thermal performance of building envelopes in controlling heat transfer due to conduction and solar radiation. Solar radiation from glass elements can increase the heat load in mosque spaces that have relatively large openings and large volumes. Therefore, optimising glass materials is an important strategy for improving the energy efficiency and thermal comfort of buildings in tropical environments. This study aims to determine the OTTV value of the Baiturrohman Mosque in Jember using building design documents and SNI 6389:2020 requirements. In addition, this study also investigates how the type of glass selected affects the reduction in OTTV value. The method used is quantitative-qualitative, and the experimental case study method is used to compare two types of glass in the same building configuration. The variables analysed include the thermal transmittance (U-value) and shading coefficient (SC) of the glass as the main parameters that affect the amount of heat radiation entering through the façade.The calculation results show that the use of 5 mm clear glass with a U-value of 5.8 W/m²K and SC 0.97 produces an OTTV value of 36.64 W/m². Next, a material substitution was carried out using Panasap Blue Green glass with a U-value of 5.8 W/m²K but an SC of 0.67. This change resulted in an OTTV value of 30.58 W/m². There was a decrease of 6.06 W/m² or about 16.54% compared to the initial condition. This decrease shows that the reduction in the SC value directly contributes to the reduction of solar heat radiation entering through the building envelope, even though the thermal conductivity value of the glass did not change. The results of this study prove that selecting the right type of glass can be an effective strategy in optimising the OTTV value of mosques without requiring structural changes to the building facade. This strategy is relevant for application in public buildings in tropical regions to support energy efficiency and improve the thermal comfort of worship spaces.