Muhamad Zia Ulhaq
Universitas Sultan Ageng Tirtayasa

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

Analisis Performa PID, Fuzzy-PID, dan Model Predictive Control (MPC) untuk Pengaturan Ketinggian Air Bendungan Muhamad Zia Ulhaq; Desmira Desmira; Miftakhul Azamah; Imratul Nazifah; Meisya Dwi Rizkiana; Yoga Angga Pratama
Teknik: Jurnal Ilmu Teknik dan Informatika Vol. 6 No. 1 (2026): Mei : Teknik: Jurnal Ilmu Teknik dan Informatika
Publisher : LPPM Sekolah Tinggi Ilmu Ekonomi - Studi Ekonomi Modern

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51903/teknik.v6i1.1063

Abstract

This study analyzes the performance of three types of controllers—PID, Fuzzy-PID, and Model Predictive Control (MPC)—in maintaining water level stability in a dam system. Proper water level regulation is essential to prevent flooding, ensure adequate water distribution, and maintain the structural safety of the dam. Previous studies have widely implemented PID and Fuzzy-PID controllers; however, MPC offers significant advantages through system prediction and multivariable optimization. This research compares the performance of the three controllers through simulation analysis using a second-order mathematical model. The results indicate that MPC has the potential to deliver a faster settling time and a smaller steady-state error compared to PID and Fuzzy-PID, although it requires higher computational complexity.
Studi Analisis Perbaikan Air Conditioner Terhadap Efektivitas dan Efisiensi Sistem Pendingin Ruangan Ghifari Permana; Tita Nurdaiyah; Avisa Marellaningtyas; Daffa Abdillah Rizal; Muhamad Zia Ulhaq; Siti Nurasiyah; Desmira Desmira
Teknik: Jurnal Ilmu Teknik dan Informatika Vol. 6 No. 2 (2026): Oktober: Teknik: Jurnal Ilmu Teknik dan Informatika
Publisher : LPPM Sekolah Tinggi Ilmu Ekonomi - Studi Ekonomi Modern

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51903/teknik.v6i2.1286

Abstract

Air conditioner (AC) is a vital device in room cooling systems widely used in tropical climate regions such as Indonesia. With high usage intensity, AC units are susceptible to performance degradation due to dirt accumulation, component damage, and lack of regular maintenance. This study aims to analyze the impact of comprehensive repair (overhaul) of indoor AC units on improving cooling effectiveness and energy consumption efficiency. Research methods include field observation, measurement of thermal parameters before and after repair, and comparative data analysis. The research object is a 1 HP split AC unit that has been operating for more than three years with identified damage symptoms. Components inspected and repaired include evaporator, blower fan, air filter, and condensate drainage system. The results showed that after overhaul, the air outlet temperature decreased by an average of 3.2°C, the coefficient of performance (COP) increased from 2.41 to 3.18, and electrical power consumption decreased by 12.7%. The conclusion of this study confirms that regular maintenance and proper overhaul procedures significantly improve the performance and energy efficiency of AC systems.