Claim Missing Document
Check
Articles

Found 5 Documents
Search

Efisiensi Energi Listrik Pada Pusat Perbelanjaan X Kota Tangerang Ade Ayu Rahmawati; Radimas Putra Muhammad Davi Labib; Bagus Tri Kuncoro
Jurnal Teknik Vol. 14 No. 2 (2025): Juli - Desember 2025
Publisher : Universitas Muhammadiyah Tangerang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31000/jt.v14i2.13887

Abstract

Penggunaan energi di pusat perbelanjaan memiliki kontribusi signifikan terhadap konsumsi energi perkotaan, khususnya di Kota Tangerang yang terus berkembang. Penelitian ini bertujuan untuk mengevaluasi tingkat efisiensi energi di sejumlah pusat perbelanjaan di Kota Tangerang serta mengidentifikasi strategi peningkatan yang dapat diterapkan. Metodologi yang digunakan meliputi survei penggunaan energi untuk menghitung tingkat Intensitas Konsumsi Energi (IKE), analisis operasional fasilitas, dan wawancara dengan pengelola gedung. Hasil penelitian menunjukkan bahwa sebagian besar pusat perbelanjaan masih memiliki Peluang Hemat Energi (PHE) untuk meningkatkan efisiensi, terutama melalui optimalisasi sistem pencahayaan, pendinginan, serta penerapan teknologi hemat energi seperti sistem otomasi gedung. Selain itu, program kesadaran energi bagi tenant dan pengunjung juga berpotensi mengurangi konsumsi energi secara keseluruhan. Studi ini merekomendasikan penerapan standar manajemen energi yang lebih ketat dan insentif bagi pusat perbelanjaan yang berhasil mengurangi konsumsi energi mereka secara signifikan.Kata Kunci: IKE, Efisiensi Energi, Peluang Hemat Energi
Two-Stage Adaptive Normalization Based on Exponential Moving Average for DC Offset and Variance Non-Stationarity Compensation in Real-Time Volcanic Seismic Signal Preconditioning Radimas Putra Muhammad Davi Labib; Ratri Andinisari; Mochammad Rifki Ulil Albaab; Ferty Lanisa Putri; Fernanda Sucitra Murti; Agam Nizar Dwi Nur Fahmi
JURNAL PENDIDIKAN VOKASIONAL TEKNIK ELEKTRONIKA (JVoTE) Vol. 8 No. 2 (2025): Vol 8 No 2 (2025): JURNAL PENDIDIKAN VOKASIONAL TEKNIK ELEKTRONIKA (JVoTE)
Publisher : PENDIDIKAN VOKASIONAL TEKNIK ELEKTRONIKA FAKULTAS TEKNIK UNIVERSITAS NEGERI JAKARTA

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21009/jvote.v8i2.71692

Abstract

Volcanic seismic signals output by digitizers as raw counts carry the accumulated imperfections of the entire acquisition chain—specifically, significant DC offset and large-scale variability—thereby violating the stationarity assumption underpinning downstream estimation blocks. This study proposes a two-stage adaptive normalization architecture based on the Exponential Moving Average (EMA) to serve as a statistical pre-conditioning block prior to the Kalman Filter. The first stage removes the DC offset using a recursive mean estimator—analytically equivalent to a first-order high-pass filter—while the second stage performs Z-Score standardization based on a running estimate of the standard deviation. Testing was conducted on a 386.48-second vertical-channel recording from the Leker (LKR) station at Mount Semeru (sampled at 100 Hz; 38,649 samples), characterized by a DC offset of −7,292.4 counts and a variance dynamic ratio of 10.42. With an adaptation constant of 0.005, the effective cutoff frequency of 0.0796 Hz lies approximately eighteen times below the 1.42 Hz fundamental frequency of the harmonic tremor, resulting in a passband attenuation of only −0.035 dB. Results demonstrate that the estimator locks onto the bias with a discrepancy of 7.72 counts (0.070% of the signal's standard deviation), reduces the dynamic ratio to 1.52, and yields an output where 99.989% of samples fall within the ±3 range. The Normalized Innovation Squared test confirms that the static covariance parameters of the Kalman Filter remain consistent with the normalized input, yielding a ratio of 1.17 compared to 17.10 for the raw input—an improvement factor of 14.6. The algorithm requires 8 bytes of state memory and 0.0104% processor utilization on an ARM Cortex-M4F at 48 MHz, whereas static normalization of the same recording requires 151.0 kB and cannot be implemented on that platform.
Machine Learning-Based State of Charge Estimation for the Energy Management System of a 3 GT Hybrid Battery-Solar Electric Boat Radimas Putra Muhammad Davi Labib; Fernanda Sucitra Murti; Ferty Lanisa Putri; Bagus Anggraini; Alfarid Hendro Yuwono; Parama Diptya Widayaka
JURNAL PENDIDIKAN VOKASIONAL TEKNIK ELEKTRONIKA (JVoTE) Vol. 8 No. 2 (2025): Vol 8 No 2 (2025): JURNAL PENDIDIKAN VOKASIONAL TEKNIK ELEKTRONIKA (JVoTE)
Publisher : PENDIDIKAN VOKASIONAL TEKNIK ELEKTRONIKA FAKULTAS TEKNIK UNIVERSITAS NEGERI JAKARTA

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21009/jvote.v8i2.72072

Abstract

Small-scale electric boats face highly restricted energy margins due to limited battery capacities, whereas a single fishing cycle typically lasts up to eight hours. In operational contexts, the state of charge (SoC) acts as the primary decision variable in the Energy Management System (EMS), making the overall system accuracy heavily dependent on the precision of SoC estimation. For LiFePO4 batteries, the highly flat open-circuit voltage (OCV) curve in the middle SoC range causes conventional estimation methods to lose their sensitivity. This study proposes an integrated simulation model for a 3 GT electric fishing boat, combining a 48 V 200 Ah LiFePO4 battery pack using an OCV-resistance-RC approach, an 860 Wp photovoltaic array, and a 10 kW Brushless DC (BLDC) motor. This modeling generates an eight-hour mission dataset at a one-minute resolution, comprising 60 voyage variations equivalent to 28,800 samples. Random Forest and Long Short-Term Memory (LSTM) algorithms are evaluated using data leakage-free feature engineering that relies solely on measured quantities from the battery management system, excluding cumulative current integration. Based on 5,052 test samples, the LSTM method achieves superior accuracy with an RMSE of 0.587 and an R2 of 0.9970, outperforming Random Forest, which yields an RMSE of 0.696 and an R2 of 0.9958. However, the LSTM computation demands approximately 33 times longer training time. Energy audit results demonstrate that the photovoltaic array supplies 29.4% of the total mission energy requirement, with 8 out of 60 voyages reaching the battery protection threshold. This confirms that accurate SoC estimation is an absolute operational requirement to ensure the electrical reliability of fishing boats.
IMPLEMENTASI ALAT PEMANTAU KUALITAS UDARA REAL-TIME BERBASIS INTERNET OF THINGS UNTUK AREA INDUSTRI MENGGUNAKAN PLATFORM BLYNK Ade Ayu Rahmawati; Muhamad Wahyu Iqbal; Agam Nizar Dwi Nur Fahmi; Radimas Putra Muhammad Davi Labib; Bagus Tri Kuncoro
JURNAL PENDIDIKAN VOKASIONAL TEKNIK ELEKTRONIKA (JVoTE) Vol. 8 No. 2 (2025): Vol 8 No 2 (2025): JURNAL PENDIDIKAN VOKASIONAL TEKNIK ELEKTRONIKA (JVoTE)
Publisher : PENDIDIKAN VOKASIONAL TEKNIK ELEKTRONIKA FAKULTAS TEKNIK UNIVERSITAS NEGERI JAKARTA

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21009/jvote.v8i2.72773

Abstract

Air quality in industrial environments is influenced by machine emissions, vehicle traffic, and dust particles, and therefore requires continuous monitoring. This study aims to design, implement, and test an Internet of Things-based air quality monitoring device that displays data in real time. The device was built using an Arduino Mega 2560 microcontroller and an ESP-01 module as the Wi-Fi network connector, with an MQ-7 sensor for carbon monoxide (CO), an MQ-135 sensor for mixed pollutant gases read as carbon dioxide (CO₂), a DHT11 sensor for temperature and humidity, and a DSM501A sensor for dust particles. The measurement results are displayed on a 20×4 LCD and in the Blynk application, while a buzzer and LEDs provide warnings when values exceed the programmed thresholds. Testing was carried out on July 27, 2025, from 12:00 to 15:00 at 30-minute intervals. All readings fell into the good air classification based on the device thresholds, with CO₂ levels of 0.03–0.43 ppm, CO levels of 3.77–4.95 ppm, and dust sensor output of 674–1175. Data were sent to Blynk in real time and are available as historical graphs. For regional context, the Windy map for the same date showed a highest CO of 2470 ppb (2.47 ppm), PM10 of 717 µg/m³, and AQI of 290. The device works well as an initial monitor, but calibration against a reference measuring instrument is still required before its values are compared with quality standards.
PEMBERDAYAAN RELAWAN TANGGAP BENCANA MELALUI PENERAPAN PORTABLE SOLAR-BATTERY ENERGY STORAGE SYSTEM SEBAGAI SUMBER LISTRIK DARURAT Bagus Anggraini; Akhmad Saufan; Waradzi Mustakim; Radimas Putra Muhammad Davi Labib; Muhammad Fatihuddin; Reza Febriano Armas; Chairul Hudaya
Prosiding Seminar Nasional Pengabdian Kepada Masyarakat Vol. 7 No. 1 (2026): PROSIDING SEMINAR NASIONAL PENGABDIAN KEPADA MASYARAKAT - SNPPM2026
Publisher : Lembaga Penelitian dan Pengabdian kepada Masyarakat Universitas Negeri Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Posko tanggap bencana di Indonesia kerap kehilangan pasokan listrik jaringan, sedangkan genset berbahan bakar fosil bergantung pada logistik BBM serta menimbulkan kebisingan dan emisi. Program community development ini bertujuan memperkuat kapasitas energi darurat relawan Muhammadiyah Disaster Management Center (MDMC) melalui penerapan Battery Energy Storage System portabel berbasis panel surya (Solar-BESS) yang disertai transfer teknologi. Pendekatan partisipatif dilaksanakan dalam lima tahap, mulai dari identifikasi kebutuhan hingga evaluasi dan perencanaan keberlanjutan. Dua unit dihasilkan dan diserahkan kepada mitra, yaitu unit 720 Wh berbasis LiFePO₄ (daya kontinu 800 W, panel 100 Wp) dan unit 150 Wh berbasis NMC (daya kontinu 250 W, panel 10 Wp), beserta APAR khusus baterai litium dan prosedur operasi standar (SOP). Sebanyak 40 relawan mengikuti pelatihan tentang prinsip PLTS, manajemen baterai, perhitungan beban, keselamatan, dan perawatan. Analisis skenario beban menunjukkan bahwa unit 720 Wh mampu memasok beban gabungan posko 100 W selama sekitar 5,2 jam atau penerangan 40 W selama sekitar 13 jam, dan panelnya dapat menopang penerangan sekitar 7,6 jam per hari. Program berkontribusi terhadap akses teknologi, kapasitas relawan, dan kesiapan kelembagaan mitra, sedangkan pengukuran kinerja lapangan dan kompetensi relawan diperlukan pada tahap berikutnya.