This Author published in this journals
All Journal Variabel
Ahmad Faiz Rahmatullah
Universitas Muhammadiyah Prof. Dr. Hamka, Jakarta

Published : 1 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 1 Documents
Search

Experimental Investigation of Condenser Performance in Freshwater Production from Seawater Desalination using Air-Conditioner Waste Heat Ahmad Faiz Rahmatullah; Dan Mugisidi; Oktarina Heriyani; Rifky Rifky; Ahmad Rizal Dzikrillah; Genta Prastanadira; Salman Alfariz
Variabel Vol 9, No 1 (2026): APRIL 2026
Publisher : STKIP Singkawang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26737/var.v9i1.9376

Abstract

Freshwater scarcity remains a critical global issue driven by population growth, urbanisation, and climate change. Humidification–dehumidification (HDH) desalination has attracted increasing attention as a small-scale and energy-efficient technology because it can operate using low-grade thermal energy, including waste heat from air-conditioning systems. This study experimentally evaluated the performance of a fin-tube condenser integrated into an HDH seawater desalination system powered by air-conditioner waste heat. The experimental system consisted of an air-conditioning unit, an evaporation tank, a fin-tube condenser, a cooling-water circulation unit, and instruments for measuring temperature, relative humidity, airflow velocity, and condensate yield. Experiments were carried out over three consecutive days under comparable operating conditions. The results showed that the inlet humid-air temperature ranged from 43.71°C to 45.14°C and decreased to 23.96–25.87°C after passing through the condenser. The relative humidity increased from 46.81–48.74% at the condenser inlet to 99.27–99.99% at the outlet, indicating that the humid air approached a saturated condition after cooling. The airflow velocity decreased from 1.02 m/s at the inlet to 0.63 m/s at the outlet, suggesting increased contact time between humid air and the condenser surface. The calculated dew-point condition also confirmed that the cooling process supported condensation inside the condenser. The cooling-side heat transfer rate increased from 12,272.03 W to 13,494.33 W, while the condenser effectiveness ranged from 71% to 74%. The actual condensate effectiveness production varied from 3,185 g to 3,569 g, corresponding to a condensation effectiveness of 92–95%. These findings indicate that the fin-tube condenser provides effective heat removal, supports near-saturated outlet conditions, and enables stable condensate production in an HDH desalination process. The proposed system demonstrates the potential of utilising air-conditioner waste heat for sustainable freshwater production and energy-efficient small-scale desalination applications.