Evaluation of the Implementation of Occupational Safety and Health at the Radiology Installation of the Madani Regional Hospital, Pekanbaru City in 2021 Diniati, Alni; Rahayu, Endang Purnawati; Jepisah, Doni; Herniwanti, Herniwanti; Zaman, M. Kamali
Budapest International Research and Critics Institute-Journal (BIRCI-Journal) Vol 4, No 4 (2021): Budapest International Research and Critics Institute November
Publisher : Budapest International Research and Critics University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33258/birci.v4i4.2914

Abstract

Radiological examination is carried out using a diagnostic imaging tool that emits radiation, therefore radiology installations must pay attention to aspects of the application of workers' occupational safety and health. The purpose of this study was evaluation of the implementation of occupational safety and health at the Radiology Installation of the Madani Regional Hospital, Pekanbaru City in 2021. This study uses qualitative research methods through in-depth interviews, observation and document review. The research informants were 8 people, which were determined based on the snowball sampling technique. The results obtained are standard operating procedures (SOP) for services have been made and have been socialized and implemented by officers but special SOP for occupational health and safety (K3) are not yet available, radiology installation permits are still in process, K3 training has not been implemented, installation facilities and infrastructure radiology is adequate but there are still shortcomings, archive records have been neatly and in detail in accordance with applicable regulations, reports cannot be carried out because the radiology installation is still in the permit process; some management requirements, some radiation protection requirements and technical requirements are not in accordance with applicable regulations, radiology installation safety verification is in accordance with applicable requirements. The conclusion of this study is that the application of K3 Radiology Installation at the Madani Regional Hospital is not in accordance with the regulation of the head of the nuclear energy supervisory agency number 4 of 2020. It is recommended that the Radiology Installation and related parties can complete the licensing file that is still lacking, conduct K3 training, report if the permit has been completed, meet management requirements, radiation protection requirements and technical requirements that are still lacking.
Evaluation of Active Fire Protection Facilities at gas stations in Indragiri Hulu Regency Wahyuni, Sri; Herniwanti, Herniwanti; Abidin, Aldiga Rienarti; Rahayu, Endang Purnawati; Zaman, M. Kamali
Budapest International Research and Critics Institute-Journal (BIRCI-Journal) Vol 4, No 4 (2021): Budapest International Research and Critics Institute November
Publisher : Budapest International Research and Critics University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33258/birci.v4i4.2897

Abstract

Fire is a threat to human safety, property and the environment. Fire incidents at gas stations often occur, at least from 2018-2020 there have been two fire cases in Indragiri Hulu Regency which resulted in physical and material losses. The fire occurred due to the unavailability and lack of monitoring of active fire protection facilities at gas stations. This type of research is a case study qualitative research which is determined by purposive sampling. The informants in this study consisted of 6 people, namely operators, field coordinators, technical staff, supervisors, leaders and directors of gas stations. The results obtained are that the gas station already has 2 fire detectors but does not meet the standard of SNI 03-3985-2000, Gas stations already have fire alarms but not yet installed in all buildings, gas stations already have 4 fire extinguishers and are not in accordance with Pertamina Regulation and PU Ministerial Regulation No. 26/PRT/M/2008, there is an absorbent in the form of sand with a blue tub and it is not in accordance with Pertamina standards, it already has a hydrant that meets the standard and already has hose reels. It is suggested to gas stations to increase the number of fire detectors, fire alarms, fire extinguishers, hydrants and absorbents in accordance with Pertamina standards.