UJI ERROR METER PADA KWH METER PASCABAYAR 1 PHASA MEREK MELCOINDA DAN MEREK SANXING YANG DIGUNAKAN OLEH PT PLN (PERSERO) SEBAGAI ALAT UKUR PEMAKAIAN ENERGI LISTRIK Handoyo, Nanda Restu; Tamaji
Seminar Nasional Ilmu Terapan Vol 8 No 1 (2024): Vol 8 No 1 (2024): Seminar Nasional Ilmu Terapan (SNITER) 2024
Publisher : Universitas Widya Kartika Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

PT Perusahaan Listrik Negara (Persero) or commonly abbreviated as PLN is an Indonesian state-owned company operating in the electricity sector, which has one mission, one of which is running the electricity business and other related fields, focusing on customer satisfaction, company members and shareholders. share. To make this happen, PT. PLN uses a tool called a kWhmeter to calculate the number of electrical ener-gy transactions that have been used by customers. Before a kWhmeter is installed on a customer's plot, the kWhmeter must first be tested meter error. If the test meter error reading test is not implemented, then there is a possibility that the kWhmeter will experience interference, causing inaccurate electrical energy measure-ments which can cause losses to the PT. PLN or the customer. The test meter error functions to find out the magnitude of the meter error value for each kWhmeter carried out in the PLN warehouse, if the test meter er-ror results are still within the class range, the kWhmeter is ready to be distributed to PLN customers. By im-plementing the test meter error, you can eliminate kWhmeter abnormalities caused by the product or manufac-turer making the kWhmeter. The test error meter also functions as a physical check for the kWhmeter to have no defects before it is installed on the customer's plot. The test meter error was implemented at PT. PLN (Persero) based on Directors Regulation (Perdir) 088-Z.P/DIR/2016 which is now Directors Regulation (Perdir) 0028.P/DIR/2023.
PENGONTROLAN SUHU DAN KELEMBABAN PADA RUANGAN MESIN PEMINTALAN SERAT BENANG Hidayat, Tatang; Tamaji
Seminar Nasional Ilmu Terapan Vol 8 No 1 (2024): Vol 8 No 1 (2024): Seminar Nasional Ilmu Terapan (SNITER) 2024
Publisher : Universitas Widya Kartika Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The textile industry is now entering the Industrial Era 4.0, which aims to increase production efficiency, reduce waste, and reduce costs. In the implementation of Industry 4.0, all production elements, such as equipment, operators, and products, must have intelligence. To achieve this, production machines, especially yarn spinning machines such as blowing and carding, need to be equipped with intelligent devices. Currently, these machines do not meet the requirements due to the lack of a control system that can build intelligence. Therefore, it is important to equip these machines with a monitoring system consisting of data processing modules, sensors, and data processing systems. This monitoring system is very important in the yarn spinning industry, because production control is a crucial aspect in the implementation of Industry 4.0. This study aims to design a monitoring system for blower and carding machines that can provide real-time information on the amount of production, machine operating status, and electricity usage. This data will be displayed in graphical form (dashboard) and can be accessed via a local network using a web browser on a computer or smartphone. With this system, management can monitor production activities in real-time, thereby reducing costs and increasing machine efficiency.
PENGHITUNGAN JUMLAH POB (PERSONNEL ON BOARD) DI FASILITAS ANJUNGAN LEPAS PANTAI BERBASIS COMPUTER VISION Darwis, Akbar; Tamaji
Seminar Nasional Ilmu Terapan Vol 8 No 1 (2024): Vol 8 No 1 (2024): Seminar Nasional Ilmu Terapan (SNITER) 2024
Publisher : Universitas Widya Kartika Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

This paper will discuss about the use of computer vision technology in calculating the number of people entering and leaving wellhead facilities. In general, offshore platform facilities are divided into 2 (two) types, namely wellhead facilities and processing facilities. Limiting the number of people in wellhead facilities is closely related to the availability of safety devices and evacuation equipment in emergency conditions. This limitation is occur with a strong reason, considering that at wellhead facilities there are some of dangers that have the potential to harm workers, including: high pressure, toxic gas, flammable gas and high temperature. This research is case research and field research, where from the problems that occur in the field, data will be collected in the form of solutions that have been implemented, further be analyzed and put forward better and more efficient solutions (in this case utilizing computer vision technology).
EFEKTIFITAS DIGITALISASI IOT VIBRATION ONLINE MONITORING DALAM PENINGKATAN AKURASI PREDICTIVE MAINTENANCE PADA MAIN FUEL OIL PUMP MESIN PLTG MITSUBISHI MW-701 Romdhoni, Atsirur; Tamaji
Seminar Nasional Ilmu Terapan Vol 8 No 1 (2024): Vol 8 No 1 (2024): Seminar Nasional Ilmu Terapan (SNITER) 2024
Publisher : Universitas Widya Kartika Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

PT PLN Indonesia Power UBP Bali manages 24 power generation units that play a critical role in ensuring a stable electricity supply for the island of Bali. The large number of generators necessitates an effective maintenance strategy. Predictive Maintenance, which was previously performed manually, required significant time and human resources. However, the digitalization of maintenance practices through the Internet of Things (IoT) has opened up new opportunities for enhancing machine maintenance effectiveness in the industry. This paper explores the effectiveness of an IoT-based Vibration online monitoring system in improving the accuracy of Predictive Maintenance for the Main Fuel Oil Pump of the Mitsubishi MWH-701 Gas Turbine engine. By utilizing vibration sensors integrated into the IoT system, the operational data of the pump can be monitored in real-time, enabling early detection of potential issues. This study analyzes the data generated from online vibration monitoring to enhance the accuracy of manual measurements regarding the pump's mechanical condition and to identify predictive patterns that may trigger maintenance interventions. The findings demonstrate that the implementation of this system not only improves the accuracy of damage prediction but also significantly reduces equipment downtime and unexpected maintenance costs. These results highlight the importance of digitalization in enhancing operational efficiency and machine reliability. This paper is expected to serve as a reference for the industry in adopting IoT technology technology to improve machine maintenance practices, particularly in Predictive Maintenance.
PERENCANAAN PEMANFAATAN PEMBANGKIT LISTRIK TENAGA ENERGI BARU TERBARUKAN (PLT-EBT) PADA LOKASI WISATA DI DAERAH TERPENCIL Permana, Ika Dian; Tamaji
Seminar Nasional Ilmu Terapan Vol 8 No 1 (2024): Vol 8 No 1 (2024): Seminar Nasional Ilmu Terapan (SNITER) 2024
Publisher : Universitas Widya Kartika Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Indonesia is located in a tropical region and is crossed by the equator, therefore the Indonesian territory will be continuously illuminated by the sun during the day. This is an added value that must be utilized for equitable development in Indonesia. The need for energy throughout Indonesia is sometimes hindered by geographical conditions in the form of mountains and wilderness. Where the PLN electricity network has difficulty reaching remote areas. Meanwhile, remote areas sometimes have tourism potential that can be developed further, such as mountain peaks or hills, waterfalls in the middle of the forest and so on. Utilization of renewable energy can use solar panels, wind turbines or water turbines. This journal uses descriptive research methods that collect data from New Renewable Energy Power Plant (PLT-EBT) system equipment consisting of Solar Power Plants (PLTS), Wind Power Plants (PLTB) and Hydro Power Plants (PLTA) and calculation of electrical energy consumption at simple tourist attractions as input for mathematical simulations
Analisis Pengaruh Suhu Lingkungan Terhadap Kinerja dan Hasil Produksi Mesin Es Maker ICB-2000P Fajrin; Tamaji
Seminar Nasional Ilmu Terapan Vol 8 No 1 (2024): Vol 8 No 1 (2024): Seminar Nasional Ilmu Terapan (SNITER) 2024
Publisher : Universitas Widya Kartika Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The increasing demand for ice across various sectors, such as the food, beverage, and hospitality industries, is driven by changes in modern lifestyles and extreme weather conditions, particularly during dry seasons. This study aims to explore the impact of ambient temperature on the performance of the ICB-2000P ice maker. The research was conducted in Penajam Paser Utara Regency from October 1 to 2, 2024, utilizing temperature measurement tools and electric current meters. The results indicate that lower ambient temperatures (below 30 degrees Celsius) enhance ice production efficiency, with total production reaching 213.72 kg compared to 89.05 kg at temperatures above 30 degrees Celsius. Additionally, electricity consumption also increased at higher temperatures, rising from 5262 VA to 5525 VA. Thus, this study underscores the importance of managing room temperature to optimize the performance of ice makers. Recommendations for improving air circulation and using insulation are expected to enhance ice production efficiency and reduce operational costs in the long term.
PENURUNAN MEDAN ELEKTROMAGNETIK MENGGUNAKAN SANGKAR FARADAY SEBAGAI MITIGASI RISIKO PELAKSANAAN ENERGISASI TRANSMISI YANG MENGALAMI SINGGUNGAN RIGHT OF WAYS (ROW) DENGAN SUMUR MIGAS Nugroho, Aditya Widhi; Tamaji
Seminar Nasional Ilmu Terapan Vol 8 No 1 (2024): Vol 8 No 1 (2024): Seminar Nasional Ilmu Terapan (SNITER) 2024
Publisher : Universitas Widya Kartika Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Primary energy sources such as electrical, oil and gas are energy that is really needed by society and industries. The provision process of these energy sources must adhere to applicable regulations, including the Right of Way (ROW) rules. In the case of the 500 kV Transmission Network Construction from New Aur Duri to Peranap on Sumatra Island, Indonesia, there is a regulatory conflict regarding ROW between the electricity provider (PT. PLN (Persero)) and the oil & gas provider (PT. Pertamina (Persero)), where there is a ROW tangency between transmission tower span overlaps and the free radius of the oil wells. Considering the critical need for both energy sources, the energization of the 500 kV New Aur Duri – Peranap Transmission Line must be carried out with strict of attention to safety in the vicinity of PT. Pertamina’s wells. Therefore, the Faraday Cage method will be used as one of mitigation risks of potential fires due to induced electric and magnetic fields. In this paper, the author explains the risk analysis of the energization implementation for the 500 kV New Aur Duri – Peranap Transmission and Faraday Cage construction design aimed at reducing electric field induction around PT Pertamina’s wells. By implementing this safety measure, the energization of the 500 kV New Aur Duri – Peranap Transmission Line can proceed safely, even in the overlapping ROW area.
ANALISA KEBUTUHAN SISTEM PROTEKSI PETIR PADA METERING REGULATING STATION KIOSK PELANGGAN PT PERUSAHAAN GAS NEGARA .TBK SESUAI DENGAN PERATURAN UMUM INSTALASI PENANGKAL PETIR DAN SNI 03-7015-2004 Siswanto, Eko Haris; Tamaji
Seminar Nasional Ilmu Terapan Vol 8 No 1 (2024): Vol 8 No 1 (2024): Seminar Nasional Ilmu Terapan (SNITER) 2024
Publisher : Universitas Widya Kartika Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

PT Perusahaan Gas Negara .Tbk (PGN) is a Pertamina Gas Sub-Holding which operates in the field of natural gas transportation. In the distribution process it is necessary to regulate the pressure according to customer needs and measure the volume of use. One of the equipment used to regulate the pressure to customers is metering. Regulating Station Kiosk (MRS Kiosk),to obtain Approval for Eligibility for Operation (PLO) from the Directorate General of Oil and Gas - Ministry of Energy and Mineral Resources, for operational and public safety it is necessary to install a lightning protection system and grounding system, calculating the need for a lightning strike protection system can use standards that already exists, namely the General Regulations for Lightning Distribution Installations (PUIPP) and SNI 03-7015-2004. Based on the data obtained, the MRS Kiosk of PT Bintang Float Glass in Subang City is on a flat plain with a low level of vulnerability to lightning strikes, namely 31 days of thunder per year, and the dimensions of the MRS Kiosk are 10.4 meters long, 6.6 meters wide and 3.65 meters high so that bycalculating with PUIPP standards and SNI 03-7015-2004 the same results are obtained, namely that it does not require a lightning protection system.
MONITORING SISTEM DC 110 VOLT DI GARDU INDUK BERBASIS ANDROID Nurholis; Tamaji
Seminar Nasional Ilmu Terapan Vol 8 No 1 (2024): Vol 8 No 1 (2024): Seminar Nasional Ilmu Terapan (SNITER) 2024
Publisher : Universitas Widya Kartika Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The 110 Volt DC system is a critical component in substations that supports the operation of control and protection devices. Instability in voltage or current within this system can have severe consequences on the overall performance of the substation. Therefore, real-time monitoring of the 110 Volt DC system is crucial. This research aims to design and implement an Android-based monitoring system supported by Internet of Things (IoT) technology. The system utilizes voltage and current sensors integrated with a microcontroller, transmitting data to an Android application via a data communication protocol. The data received by the application can be analyzed in real-time, providing essential information about parameter deviations fromoperational standards. Additionally, the system includes an early warning feature that enables technicians to respond to potential issues before they affect the substation’s operations. Testing has demonstrated that this system effectively improves monitoring efficiency and reduces operational risks in substations. By applying this technology, disruptions in the DC system can be detected early, allowing for rapid and accurate preventive action.
ANALISIS PERANCANGAN SISTEM KONTROL DAN MONITORING BERBASIS ARDUINO UNO VIA INTERNET PADA PEMANFAATAN AIR KONDENSAT PADA KULKAS Bagja, M. Fathan Sugih; Tamaji
Seminar Nasional Ilmu Terapan Vol 8 No 1 (2024): Vol 8 No 1 (2024): Seminar Nasional Ilmu Terapan (SNITER) 2024
Publisher : Universitas Widya Kartika Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Condensate water is a water which is resulted from the condensation process, usually thrown away regardless of its use. In this journal, a control system for the refrigeration system for the utilization of condensate water will be analyzed. This design includes the design of a cabin temperature control system and an automatic condensate water spraying control system.Arduino UNO will be used as controller and DS18B20 sensor will be used as a detector and also as a feedback. In addition, the monitoring system is designed to use laptop, LCD and smartphone screens with the ThingSpeak application. The result is the designed on-off control system be able to maintain the cabin temperature at the setpoint of 4.5oC. But there are still errors in the range of 0.12oC-0.13oC. Meanwhile, in the condensate water spraying control system, the spraying automatically turns on when the condenser exit temperature exceeds the setting temperature of 39oC, with an error in the range of 0.1oC-0.44oC. In addition, the monitoring system on ThingSpeak and LCD produces temperature graphs with values and patterns which be the same. Furthermore, the actual COP of the refrigeration system which fluctuates at value of 3.28 is greater than the actual COP without spraying which fluctuates at value of 2.95. This is shown by a graph of the actual COP with sprays which be higher at any time. The electric power of the refrigerator with spraying (104 W) is slightly lower than the system without spraying (114 W).