Mokhammad Isnaeni Bambang Setyonegoro
Jurusan Teknik Elektro Dan Teknologi Informasi, Fakultas Teknik, Universitas Gadjah Mada

Published : 13 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 5 Documents
Search
Journal : Jurnal Nasional Teknik Elektro dan Teknologi Informasi

Pengaruh Penutupan-Balik Tak-Sinkron terhadap Generator Induksi 3-Fase dalam Skema Pembangkitan Tersebar M. Isnaeni B. S.; F. Danang Wijaya; Eka Firmansyah
Jurnal Nasional Teknik Elektro dan Teknologi Informasi Vol 6 No 4: November 2017
Publisher : Departemen Teknik Elektro dan Teknologi Informasi, Fakultas Teknik, Universitas Gadjah Mada

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1258.822 KB)

Abstract

Small and medium-scale plants connected to the distribution line form a distributed generation (DG) system. Unsynchronized reclosing, due to the operation of a recloser, is an important issue in DG systems. In this paper, simulations of typical DG system are performed to show the effect of unsynchronized reclosing. The simulation results show that unsynchronized reclosing causes the generator to experience over speed, over and under voltage, and over current, which can damage or reduce the life of the generator. A permanent short circuit that causes the contact of recloser to open and close repeatedly has a worse effect than a temporary short circuit. Opening the circuit breaker at point of common coupling with the installation of dummy load can reduce the bad effect of unsynchronized reclosing.
Evaluasi Kinerja IMAG pada Pembangkit Listrik Tenaga Mikrohidro Cokro Tulung Kabupaten Klaten Mahalla; Suharyanto; M. Isnaeni B. S.
Jurnal Nasional Teknik Elektro dan Teknologi Informasi Vol 2 No 1: Februari 2013
Publisher : Departemen Teknik Elektro dan Teknologi Informasi, Fakultas Teknik, Universitas Gadjah Mada

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1063.668 KB)

Abstract

IMAG (Induction Motor as Asynchronous Generator) or induction motor that is used as an asynchronous generator having been widely used in micro-hydro Power Plant (MHP)usually in small capacity, i.e below 100 Kw. The reason for the widespread popularity of induction generator is owing to it’s capability to generate the power from variable speed as well as constant speed prime movers, low unit cost, reduced maintenance, rugged and brushless rotors, absence of a separate d.c. source for excitation, absence of moving contacts, inherent overload protection, improved performance due to low transient impedance, natural protection against short circuit, there are many on the market etc. Their main disadvantage is poor voltage and frequency regulation under varying load and speed. Imag performance evaluation needs to be analyzed including it is voltage stability analysis and frequency analysis in expenses. Based on the analysis of the system in general, efficiency is 47,38% total imag and positions the turbine room and Imag are still far from flood-free area, so a high fall (head) can be increased from 1 m up to 2.21 m, this can increase the potential and generated power of 82.56% Based on the analysis of the daily load, major load changes affect changes in voltage and frequency output of the imag, this was due to the load current controller can not work fast (slow response) to divert the major load changes to the load apparent (ballast load). There are several methods that can be done to control the voltage and frequency, one method of which is to adjust the load (dummy load). The results of the analysis will be in the form of recommendations for improvement so that the MHP and the frequency of the voltage instability can be obtained to ensure the quality of the electricity generated by Imag at MHP system.
Peningkatan Stabilitas Transien pada Turbin Angin Berbasis DFIG Menggunakan SFCL tipe Bridge Doane Puri Mustika; Sasongko Pramono Hadi; Mokhammad Isnaeni B; Mohd. Brado Frasetyo; Tumiran
Jurnal Nasional Teknik Elektro dan Teknologi Informasi Vol 11 No 4: November 2022
Publisher : Departemen Teknik Elektro dan Teknologi Informasi, Fakultas Teknik, Universitas Gadjah Mada

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22146/jnteti.v11i4.5031

Abstract

Today’s electrical energy is mainly produced by burning fossil fuels, which actually has negative effects on earth, namely global warming. In the electricity sector, measures that can be taken to reduce emissions include replacing conventional generators with renewable ones. Wind energy is one type of new renewable energies (NREs) with the potential to reduce emissions. Wind turbines widely used today are variable speed wind turbines, such as the doubly-fed induction generator (DFIG). DFIG has numerous advantages, like having more flexibility and being able to control both active and reactive powers. However, it often encounters instability problems in its system when experiencing transients. Therefore, a solution that can improve transient stability in DFIG is needed. The bridge-type superconducting fault current limiter (SFCL) was used in this research as a solution to improve the transient stability in DFIG, which consisted of two diodes and two inductors. This bridge-type SFCL operates by limiting the current in the event of faults, preventing the system from voltage drops or trips. The simulation results were analyzed under two circumstances. In the first circumstance, the 9 MW DFIG wind turbine system which was given faults using SFCL produced a voltage value of 219 V, with a more stable frequency value of 50 Hz, and an active power value of 9 MW. Meanwhile, when a system that did not use SFCL was given faults, the voltage dropped from the normal state of 219 V to 100 V. The frequency value was less stable, fluctuating between 49.75 Hz and 50.25 Hz, while the active power dropped from 9 MW to 6 MW. This result proves that the bridge-type SFCL method effectively increases the transient stability in DFIG.
Penetrasi Fotovoltaik dengan Metode MILP dan Pertimbangan Pembebanan Minimal Teknis Alfi Bahar; Muhammad Yasirroni; Sarjiya; M. Isnaeni Bambang Setyonegoro
Jurnal Nasional Teknik Elektro dan Teknologi Informasi Vol 12 No 1: Februari 2023
Publisher : Departemen Teknik Elektro dan Teknologi Informasi, Fakultas Teknik, Universitas Gadjah Mada

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22146/jnteti.v12i1.4531

Abstract

Technological development and the reduction of installation costs have caused a rapid growth of solar power plants in Indonesia. The National Electricity Company (Perusahaan Listrik Negara, PLN) strives to achieve the energy mix of renewable energy to 23% by 2025. Solar power plants are unique in that they only supply their power during the daytime. It makes solar power plants connected to the power system change the load profile of the Java-Bali system. In this study, the penetration of solar power plants changed the scheduling of the Java-Bali system because the penetration was installed to the technical minimum loading of existing power plants. When penetration is too big, thermal generator scheduling failure is possible. Unit commitment and economic dispatch with mixed-integer linear programming (MILP) method using CPLEX and Python were carried out to calculate the fuel and generation costs per kWh before and after the penetration. MILP was used to solve the cost fuel equation, namely an integer and nonlinear mix equations, that are challenging to be solved using standar nonlinear programming methods. Due to the use of the MILP-UC, all objective function equations and restraint functions must be linear functions. The tests were conducted for three years, from 2023 to 2025. Simulation results on the Java-Bali system show that the capacity of solar power plants penetrating the Java-Bali system against the peak load will be 52%, 52%, and 50% in 2023, 2024, and 2025, respectively. Meanwhile, penetration of solar power plants to technical minimum loading of existing power plants resulted in the fuel cost falling by 23% in 2023 and 22% in 2024 and 2025. Lastly, the cost of generation per kWh will be decreased by 8% in 2023 and will be as low as 7% in 2024 and 2025.
Prakiraan Beban Listrik Menggunakan Metode Jaringan Saraf Tiruan dengan Data yang Terbatas Elang Bayu Trikora; Sasongko Pramonohadi; M. Isnaeni Bambang Setyonegoro
Jurnal Nasional Teknik Elektro dan Teknologi Informasi Vol 12 No 3: Agustus 2023
Publisher : Departemen Teknik Elektro dan Teknologi Informasi, Fakultas Teknik, Universitas Gadjah Mada

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22146/jnteti.v12i3.6437

Abstract

As time changes, electric load demand forecasting is one of the vital things in generation and distribution planning. Various ways can be implemented in forecasting electrical energy demands, one of which is by using the artificial neural network method, which is a method that mimics the ability of the human brain to receive an input and then carry out processing between the neurons within to produce information based on the processes that occur within the neurons. This research uses a neural network method to forecast the electric load in Jayawijaya Regency. This research builds a neural network architecture suitable to the data obtained from National Electricity Company (Perusahaan Listrik Negara, PT PLN Indonesia) UP 3 Wamena to find an architecture model suitable with high accuracy. Due to the limited data owned to forecast electric load, an interpolation method based on the owned original data was carried out to increase the amount of the existing data. In this way, more data can be used as input, allowing the model to forecast load requirements more accurately. These propagated data were used as input data in the artificial neural network model. After conducting iterative testing using a neural network, it is found that the model that fitted the data was feed-forward long short-term memory (LSTM) network, this model can obtain errors in accordance with the standards of a model to perform forecasts of 0.04% with nine epochs.