Claim Missing Document
Check
Articles

Found 4 Documents
Search

Produced Water Treatment Planning Using Corrugated Plate Interceptor and Ultra Filtration for Water Recycling Novena Lany Pangestu; Nurulbaiti Listyendah Zahra; Ariyanti Sarwono; I Wayan Koko Suryawan
Jurnal Serambi Engineering Vol 6, No 4 (2021): Oktober 2021
Publisher : Fakultas Teknik

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32672/jse.v6i4.3473

Abstract

Produced water generated by the oil and gas industry, when treated properly, will produce water that is ready to be reused, such as for watering plants. This planning is done by treating the produced water with Corrugated Plate Interceptor (CPI) and Ultra Filtration units. This research aims to analyze the design details needed in the recycling of produced water with CPI and Ultra Filtration units. After determining the design criteria used, the dimensions for each unit are obtained. Data was collected using secondary data directly from the study site and quantitative method was used for data analysis. The land area for one CPI unit requires 55 m2 with a volume of 110 m3. The Reynolds number and Froude number for CPI units meet the design criteria with 419.8 and 0.24, respectively. The ultra-filtration unit was selected with a Flux specification of 0.15 m3/m2.hour with an operational duration of 24 hours. The results of processing with the CPI unit can at least produce oil and fat effluent of 0.038 mg/L, with the threshold for water quality is 1 mg/L. Produced water treatment planning with CPI configuration and UF membrane with storage tank requires a total land area of 63.97 m2..
SELECTION OF AMMONIA AND TSS REMOVAL IN EFFLUENT WATER FROM DURI KOSAMBI IPLT USING ANALYTIC HIERARCHY PROCESS (AHP) Farhan Muhammad Hilmi; Reifaldy Tsany Betta Aryanto; Sri Dewi Handayani; Yesaya Emeraldy Priutama; Intan Rahmalia; Evi Siti Sofiyah; Ariyanti Sarwono; I Wayan Koko Suryawan
Jurnal Arsip Rekayasa Sipil dan Perencanaan Vol 5, No 1 (2022): Jurnal Arsip Rekayasa Sipil dan Perencanaan
Publisher : Prodi Magister Teknik Sipil Unsyiah

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24815/jarsp.v5i1.24481

Abstract

The ammonia and total suspended solids (TSS) content in the wastewater of IPLT Duri Kosambi Jakarta City still does not meet the standard. It requires further processing that needs to be applied. The three treatments that are used as alternatives are GAC Adsorption, Zeolite Adsorption, and Built-Up Wetlands. The purpose of this study is to analyze the best alternative suitable for use as advanced processing in IPLT DuriKosambi with analysis of decision-making analysis. Analysis decision-making is carried out using the analytical hierarchy process (AHP) using four criteria: construction costs, TSS removal efficiency, ammonia removal efficiency, and Human Resources (HR) requirements. The highest scores of the GAC Adsorption, Zeolite Adsorption, and Constructed Wetland alternatives were 0.41; 0.30l, and 0.28. So that the GAC unit is the unit selected based on the criteria set in the AHP criteria.
DETERMINATION OF WATER QUALITY INDEX (WQI) CENTRAL JAVA PROVINCE WATER BODY BASED ON TOTAL COLIFORM Iva Yenis Septiariva; Hashfi Hawali Abdul Matin; Novi Kartika Sari; Ariyanti Sarwono; I Wayan Koko Suryawan
Journal of Green Science and Technology Vol 5, No 2 (2021): VOL 5, NO 2 (2021): JOURNAL OF SCIENCE AND TECHNOLOGY VOL. 5 NO. 2 SEPTEMBER 202
Publisher : FAKULTAS TEKNNIK UNIVERSITAS SWADAYA GUNUNG JATI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33603/jgst.v5i2.5752

Abstract

In recent years, the Central Java Province municipal river's water quality in the area is classified as heavily polluted. Therefore, research on water quality and its pollution level needs to be carried out in the Surakarta municipal river, especially in the Central Java Province. This study aimed to determine water quality and the pollution conditions in the Surakarta municipal river and analyze the conditions of the pollution load in the river at a predetermined observation point. This research was conducted using a survey method field with secondary data. The analysis was carried out using the method water quality index (WQI). The results showed The WQI change from heavily polluted to lightly polluted was measured at several observation locations from 2016 to 2018. The changes in the measured pollution index from 2016 to 2018 by coliform.
DETERMINATION OF WATER QUALITY INDEX (WQI) CENTRAL JAVA PROVINCE WATER BODY BASED ON TOTAL COLIFORM Iva Yenis Septiariva; Hashfi Hawali Abdul Matin; Novi Kartika Sari; Ariyanti Sarwono; I Wayan Koko Suryawan
Journal of Green Science and Technology Vol 5 No 2 (2021): VOL 5, NO 2 (2021): JOURNAL OF SCIENCE AND TECHNOLOGY VOL. 5 NO. 2 SEPTEMBER 2021
Publisher : Faculty of Engineering, Universitas Swadaya Gunung Jati

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33603/jgst.v5i2.5752

Abstract

In recent years, the Central Java Province municipal river's water quality in the area is classified as heavily polluted. Therefore, research on water quality and its pollution level needs to be carried out in the Surakarta municipal river, especially in the Central Java Province. This study aimed to determine water quality and the pollution conditions in the Surakarta municipal river and analyze the conditions of the pollution load in the river at a predetermined observation point. This research was conducted using a survey method field with secondary data. The analysis was carried out using the method water quality index (WQI). The results showed The WQI change from heavily polluted to lightly polluted was measured at several observation locations from 2016 to 2018. The changes in the measured pollution index from 2016 to 2018 by coliform.