Claim Missing Document
Check
Articles

Found 5 Documents
Search

Produced Water Treatment Planning Using Corrugated Plate Interceptor and Ultra Filtration for Water Recycling Novena Lany Pangestu; Nurulbaiti Listyendah Zahra; Ariyanti Sarwono; I Wayan Koko Suryawan
Jurnal Serambi Engineering Vol 6, No 4 (2021): Oktober 2021
Publisher : Fakultas Teknik

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32672/jse.v6i4.3473

Abstract

Produced water generated by the oil and gas industry, when treated properly, will produce water that is ready to be reused, such as for watering plants. This planning is done by treating the produced water with Corrugated Plate Interceptor (CPI) and Ultra Filtration units. This research aims to analyze the design details needed in the recycling of produced water with CPI and Ultra Filtration units. After determining the design criteria used, the dimensions for each unit are obtained. Data was collected using secondary data directly from the study site and quantitative method was used for data analysis. The land area for one CPI unit requires 55 m2 with a volume of 110 m3. The Reynolds number and Froude number for CPI units meet the design criteria with 419.8 and 0.24, respectively. The ultra-filtration unit was selected with a Flux specification of 0.15 m3/m2.hour with an operational duration of 24 hours. The results of processing with the CPI unit can at least produce oil and fat effluent of 0.038 mg/L, with the threshold for water quality is 1 mg/L. Produced water treatment planning with CPI configuration and UF membrane with storage tank requires a total land area of 63.97 m2..
SELECTION OF AMMONIA AND TSS REMOVAL IN EFFLUENT WATER FROM DURI KOSAMBI IPLT USING ANALYTIC HIERARCHY PROCESS (AHP) Farhan Muhammad Hilmi; Reifaldy Tsany Betta Aryanto; Sri Dewi Handayani; Yesaya Emeraldy Priutama; Intan Rahmalia; Evi Siti Sofiyah; Ariyanti Sarwono; I Wayan Koko Suryawan
Jurnal Arsip Rekayasa Sipil dan Perencanaan Vol 5, No 1 (2022): Jurnal Arsip Rekayasa Sipil dan Perencanaan
Publisher : Prodi Magister Teknik Sipil Unsyiah

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24815/jarsp.v5i1.24481

Abstract

The ammonia and total suspended solids (TSS) content in the wastewater of IPLT Duri Kosambi Jakarta City still does not meet the standard. It requires further processing that needs to be applied. The three treatments that are used as alternatives are GAC Adsorption, Zeolite Adsorption, and Built-Up Wetlands. The purpose of this study is to analyze the best alternative suitable for use as advanced processing in IPLT DuriKosambi with analysis of decision-making analysis. Analysis decision-making is carried out using the analytical hierarchy process (AHP) using four criteria: construction costs, TSS removal efficiency, ammonia removal efficiency, and Human Resources (HR) requirements. The highest scores of the GAC Adsorption, Zeolite Adsorption, and Constructed Wetland alternatives were 0.41; 0.30l, and 0.28. So that the GAC unit is the unit selected based on the criteria set in the AHP criteria.
DETERMINATION OF WATER QUALITY INDEX (WQI) CENTRAL JAVA PROVINCE WATER BODY BASED ON TOTAL COLIFORM Iva Yenis Septiariva; Hashfi Hawali Abdul Matin; Novi Kartika Sari; Ariyanti Sarwono; I Wayan Koko Suryawan
Journal of Green Science and Technology Vol 5, No 2 (2021): VOL 5, NO 2 (2021): JOURNAL OF SCIENCE AND TECHNOLOGY VOL. 5 NO. 2 SEPTEMBER 202
Publisher : FAKULTAS TEKNNIK UNIVERSITAS SWADAYA GUNUNG JATI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33603/jgst.v5i2.5752

Abstract

In recent years, the Central Java Province municipal river's water quality in the area is classified as heavily polluted. Therefore, research on water quality and its pollution level needs to be carried out in the Surakarta municipal river, especially in the Central Java Province. This study aimed to determine water quality and the pollution conditions in the Surakarta municipal river and analyze the conditions of the pollution load in the river at a predetermined observation point. This research was conducted using a survey method field with secondary data. The analysis was carried out using the method water quality index (WQI). The results showed The WQI change from heavily polluted to lightly polluted was measured at several observation locations from 2016 to 2018. The changes in the measured pollution index from 2016 to 2018 by coliform.
Planning of Granular Activated Carbon Unit to Remove Ammonia and TSS at IPLT X, Kota Jakarta Sri Dewi Handayani; Yesaya Emeraldy Priutama; Intan Rahmalia; Farhan Muhammad Hilmi; Reifaldy Tsany Betta Aryanto; Evi Siti Sofiyah; Ariyanti Sarwono; I Wayan Koko Suryawan
Equilibrium Journal of Chemical Engineering Vol 6, No 2 (2022): Volume 6, No 2 December 2022
Publisher : Program studi Teknik Kimia UNS

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20961/equilibrium.v6i2.61216

Abstract

ABSTRACT. Fecal sludge can be treated by conventional treatment such as pond stabilization which is commonly used to reduce organic concentrations. However, nutrients such as NH3 are still widely measured in the effluent. One of the sewerage treatments in the city of Jakarta, for example, experienced this condition. This study aims to design an appropriate technology to increase the efficiency of nutrient ammonia and total suspended solid (TSS) removal at Duri X IPLT. The unit added in the selected effluent treatment is Granular Activated Carbon (GAC). Design considerations are the characteristics of activated carbon, operating conditions (discharge and contact time), and operating mode (fixed-, expanded-, or fluidized-bed, pumped, or gravity flow). The Carbon Usage Rate for removing ammonia and TSS is 1.384 g/L and 0.378 g/L, respectively. Maintenance is required so that the granular activated carbon (GAC) unit can continue operating and functioning properly. Blockages in carbon transport pipes can occur in many pipes. This can occur due to a too-small pipe, a short bend radius of the pipe, a lack of speed, and a lack of cleaning of the pipe. The eroded pipe is also a common problem that often occurs in unlined mild steel and fiberglass reinforced plastic (FRP), usually in sharp bends.Keywords: Sewerage, ammonia, TSS, design, GAC
DETERMINATION OF WATER QUALITY INDEX (WQI) CENTRAL JAVA PROVINCE WATER BODY BASED ON TOTAL COLIFORM Iva Yenis Septiariva; Hashfi Hawali Abdul Matin; Novi Kartika Sari; Ariyanti Sarwono; I Wayan Koko Suryawan
Journal of Green Science and Technology Vol 5 No 2 (2021): VOL 5, NO 2 (2021): JOURNAL OF SCIENCE AND TECHNOLOGY VOL. 5 NO. 2 SEPTEMBER 2021
Publisher : Faculty of Engineering, Universitas Swadaya Gunung Jati

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33603/jgst.v5i2.5752

Abstract

In recent years, the Central Java Province municipal river's water quality in the area is classified as heavily polluted. Therefore, research on water quality and its pollution level needs to be carried out in the Surakarta municipal river, especially in the Central Java Province. This study aimed to determine water quality and the pollution conditions in the Surakarta municipal river and analyze the conditions of the pollution load in the river at a predetermined observation point. This research was conducted using a survey method field with secondary data. The analysis was carried out using the method water quality index (WQI). The results showed The WQI change from heavily polluted to lightly polluted was measured at several observation locations from 2016 to 2018. The changes in the measured pollution index from 2016 to 2018 by coliform.