Design of Solar Powered Charging Backpack Jonas Taverne; Firdaus Muhammad-Sukki; Ahmad Syahir Ayub; Nazmi Sellami; Siti Hawa Abu-Bakar; Nurul Aini Bani; Abdullahi Abubakar Mas’ud; Draco Iyi
International Journal of Power Electronics and Drive Systems (IJPEDS) Vol 9, No 2: June 2018
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijpeds.v9.i2.pp848-858

Abstract

This paper demonstrated a step by step process in designing a solar powered charging backpack that is capable of charging a mobile phone efficiently. A selection of existing products available on the market were reviewed and compared to ascertain the cost, size, and output capabilities. Next, the solar cell types and regulators were compared and their respective merits were also investigated. The charging system was then designed and tested before being integrated with the backpack. The results clearly showed that the system managed to charge the mobile phone. However, it was found that the excessive power dissipation has caused the linear regulator to generate significant heat.
Optimal distributed generation in green building assessment towards line loss reduction for Malaysian public hospital Mohd Effendi Amran; Mohd Nabil Muhtazaruddin; Nurul Aini Bani; Hazilah Mad Kaidi; Mohamad Zaki Hassan; Shamsul Sarip; Firdaus Muhammad-Sukki
Bulletin of Electrical Engineering and Informatics Vol 8, No 4: December 2019
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (932.755 KB) | DOI: 10.11591/eei.v8i4.1624

Abstract

This paper presents an optimization approach for criteria setting of Renewable Distributed Generation (DG) in the Green Building Rating System (GBRS). In this study, the total line loss reduction is analyzed and set as the main objective function in the optimization process which then a reassessment of existing criteria setting for renewable energy (RE) is proposed towards lower loss outcome. Solar photovoltaic (PV)-type DG unit (PV-DG) is identified as the type of DG used in this paper. The proposed PV-DG optimization will improve the sustainable energy performance of the green building by total line losses reduction within accepted lower losses region using Artificial bee colony (ABC) algorithm. The distribution network uses bus and line data setup from selected one of each three levels of Malaysian public hospital. MATLAB simulation result shows that the PV-DG expanding capacity towards optimal scale and location provides a better outcome in minimizing total line losses within an appropriate voltage profile as compared to the current setting of PV-DG imposed in selected GBRS. Thus, reassessment of RE parameter setting and the proposed five rankings with new PV-DG setting for public hospital provides technical justification and give the best option to the green building developer for more effective RE integration.
Optimal distributed generation in green building assessment towards line loss reduction for Malaysian public hospital Mohd Effendi Amran; Mohd Nabil Muhtazaruddin; Nurul Aini Bani; Hazilah Mad Kaidi; Mohamad Zaki Hassan; Shamsul Sarip; Firdaus Muhammad-Sukki
Bulletin of Electrical Engineering and Informatics Vol 8, No 4: December 2019
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (932.755 KB) | DOI: 10.11591/eei.v8i4.1624

Abstract

This paper presents an optimization approach for criteria setting of Renewable Distributed Generation (DG) in the Green Building Rating System (GBRS). In this study, the total line loss reduction is analyzed and set as the main objective function in the optimization process which then a reassessment of existing criteria setting for renewable energy (RE) is proposed towards lower loss outcome. Solar photovoltaic (PV)-type DG unit (PV-DG) is identified as the type of DG used in this paper. The proposed PV-DG optimization will improve the sustainable energy performance of the green building by total line losses reduction within accepted lower losses region using Artificial bee colony (ABC) algorithm. The distribution network uses bus and line data setup from selected one of each three levels of Malaysian public hospital. MATLAB simulation result shows that the PV-DG expanding capacity towards optimal scale and location provides a better outcome in minimizing total line losses within an appropriate voltage profile as compared to the current setting of PV-DG imposed in selected GBRS. Thus, reassessment of RE parameter setting and the proposed five rankings with new PV-DG setting for public hospital provides technical justification and give the best option to the green building developer for more effective RE integration.
Optimal distributed generation in green building assessment towards line loss reduction for Malaysian public hospital Mohd Effendi Amran; Mohd Nabil Muhtazaruddin; Nurul Aini Bani; Hazilah Mad Kaidi; Mohamad Zaki Hassan; Shamsul Sarip; Firdaus Muhammad-Sukki
Bulletin of Electrical Engineering and Informatics Vol 8, No 4: December 2019
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (932.755 KB) | DOI: 10.11591/eei.v8i4.1624

Abstract

This paper presents an optimization approach for criteria setting of Renewable Distributed Generation (DG) in the Green Building Rating System (GBRS). In this study, the total line loss reduction is analyzed and set as the main objective function in the optimization process which then a reassessment of existing criteria setting for renewable energy (RE) is proposed towards lower loss outcome. Solar photovoltaic (PV)-type DG unit (PV-DG) is identified as the type of DG used in this paper. The proposed PV-DG optimization will improve the sustainable energy performance of the green building by total line losses reduction within accepted lower losses region using Artificial bee colony (ABC) algorithm. The distribution network uses bus and line data setup from selected one of each three levels of Malaysian public hospital. MATLAB simulation result shows that the PV-DG expanding capacity towards optimal scale and location provides a better outcome in minimizing total line losses within an appropriate voltage profile as compared to the current setting of PV-DG imposed in selected GBRS. Thus, reassessment of RE parameter setting and the proposed five rankings with new PV-DG setting for public hospital provides technical justification and give the best option to the green building developer for more effective RE integration.
Distribution Power Loss Minimization via Distributed Generation, Capacitor and Network Reconfiguration Mohd Nabil Bin Muhtazaruddin; Nurul Aini Bani; Siti Armiza Mohd Aris; Hazilah Mad Kaidi; Abdul Yasser Abd Fatah; Jasrul Jamani Jamia; Firdaus Muhammad-Sukki; Siti Hawa Abu-Bakar
Indonesian Journal of Electrical Engineering and Computer Science Vol 5, No 3: March 2017
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijeecs.v5.i3.pp488-495

Abstract

This paper presents a solution to solve the network reconfiguration, DG coordination (location and size) and capacitor coordination (location and size), simultaneously. The proposed solution will be determined by using Artificial Bee Colony (ABC). Various case studies are presented to see the impact on the test system, in term of power loss reduction and also voltage profiles. The proposed approach is applied to a 33-bus test system and simulate by using MATLAB programming. The simulation results show that combination of DG, capacitor and network reconfiguration gives a positive impact on total power losses minimization as well as voltage profile improvement compared to other case studies.
Photovoltaic-integrated review and expansion need in green building landscape for bridging the malaysian RE policy Mohd Effendi Amran; Mohd Nabil Muhtazaruddin; Nurul Aini Bani; Sharipah Alwiah Syed Abd Rahaman; Nelidya Md Yusoff; Mohd Hanapi Azizul; Firdaus Muhammad-Sukki
Indonesian Journal of Electrical Engineering and Computer Science Vol 17, No 1: January 2020
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijeecs.v17.i1.pp27-35

Abstract

A literature review is presented specifically on the photovoltaic (PV) as a distributed generation (DG) integration approach and the extensiveness through renewable energy (RE) assessment criteria in current green building rating system (GBRS) to: delineate for further classification in terms of installed-capacity; identify the RE applications’ intent / aim; and recommendation for PV-type DG (PV-DG) expansion needs. The paper aims to close the gap in knowledge, by an empirical review of current RE assessment criteria and to portray the expected evolution of RE for higher installed-capacity in ensuring the government key achievement can be achieved. In considering the expansion needs in GBRS, the optimal technique for PV-DG expansion-limit would serve as a conceptual bridge between expanding mechanism and realization of the Malaysian most recent RE policy specifically on the drastically increment of RE quota. These can be achieved since various DG optimization case studies have been presented and overcome with the improvement impact on the test system, in term of power loss reduction, increased efficiency and optimal cost outcome. Future analysis as well as research direction are proposed and linked with some of the previous optimization reviews in recent literature.