Claim Missing Document
Check
Articles

Found 14 Documents
Search

Model Test Ultimate Bearing Capacity of Bakau Piles Foundation on Soft Soil Deposit Muhammad o Yunus
EPI International Journal of Engineering Vol 1 No 2 (2018): Volume 1 Number 2, August 2018 with Special Issue on Railway Engineering
Publisher : Center of Techonolgy (COT), Engineering Faculty, Hasanuddin University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25042/epi-ije.082018.15

Abstract

The pile foundation is one of the deep foundation types commonly used to support building loads when hard soil layers are deeply located. To determine the ultimate bearing capacity of a pile foundation of the load test results, there are several methods commonly used to interpretation test results such as Davisson method, Mazurkiewich method, Chin method, Buttler Hoy method and De Beer method. The aim of this study was to determine the characteristics of soft soil and bakau piles used in the study and to analyze the size of the bearing capacity ultimate of pile foundation that is modeled on a small scale in the laboratory. From the test results of material characteristics of the soil used is organic clay type with medium plasticity with specific gravity 2.75, liquid limit, LL = 50.36% and plasticity index, PI = 13.2%. While the results of testing the characteristics of bakau piles obtained average water content of 21.58%, tensile strength of 18.51 MPa, compressive strength of parallel fiber 23.75 MPa and perpendicular fiber 14.10 MPa, bending strength 106, 22 MPa, and strong split 29.91 MPa. From the result of loading test of the foundation model in the laboratory, it is found that the ultimate bearing capacity of the model without foundation is 41.00 kN with the ultimate settlement of 14.00 mm, the model of the 20 cm long bakau piles foundation is 52.00 kN with the ultimate settlement of 13.00 mm, the foundation model a 30 cm long bakau piles foundation of 54.00 kN with a 10.00 mm ultimate settlement, a 40 cm long bakau piles foundation model of 56.00 kN with an ultimate settlement of 8.50 mm.
Stability Analysis of Aifa Bridge Abutment in Fafurwar District, Bintuni Bay Regency, West Papua Province Muhammad Yunus; Zharin F Syahdinar
EPI International Journal of Engineering Vol 2 No 2 (2019): Volume 2 Number 2, August 2019 with Special Issue on Natural Disaster and Mitigat
Publisher : Center of Techonolgy (COT), Engineering Faculty, Hasanuddin University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25042/epi-ije.082019.12

Abstract

In the construction of public works infrastructure, especially road infrastructure works, bridge construction work plays a very important role besides the construction of the road itself. One of the things that deserves the attention of the planners in designing a bridge structure is the design of the substructure, this is because the substructure determines the quality and service life of a bridge. In addition, at present many cases of bridge structure failures are caused by failures of the substructure in holding the load acting on the bridge. The aim of this study was to determine the stability of the abutment to sliding failure and the stability of the abutment to overturning failure on the construction of the Aifa bridge in the Bintuni Bay Regency. From the results of the calculation of the stability of the abutments to sliding failure, when the abutments are in normal conditions was obtained safety factor (SF) values 1,907, in condition of the upper structure load is not working was obtained safety factor (SF) values 1,045 and during earthquake conditions was obtained safety factor (SF) values 1,419. While the results of the calculation of the stability of the abutments to overturning failure, when the abutments are in normal conditions was obtained safety factor (SF) values 4,640, in condition of the the upper structure load is not working was obtained safety factor (SF) values 1,658 and during earthquake conditions was obtained safety factor (SF) values 3,159. Because obtained safety factor (SF) values greater than 1, so that the stability of the abutment is safe to sliding failure and overturning failure.
Feasibility Analysis of Runway, Taxiway and Apron Dimensions of Torea Airport in Fakfak Regency, West Papua Province Muhammad Yunus; Ratna Septa Sari Tuhepaly; Ahmad Fitriadhy
EPI International Journal of Engineering Vol 4 No 2 (2021): Volume 4 Number 2, August 2021
Publisher : Center of Techonolgy (COT), Engineering Faculty, Hasanuddin University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25042/10.25042/epi-ije.082021.09

Abstract

The development of transportation sector modes, especially air transportation modes, is currently experiencing a very significant development. This is because the mode of air transportation in the form of airplanes can make people move very quickly, unlike land and sea transportation modes which require a longer time. In this regard, an airport that meets the requirements in terms of flight security and safety is needed. The aim of the study was to analyze the dimensions of the runway, taxiway, appron and evaluate the feasibility of the runway, taxiway, appron dimensions at Torea Airport in Fakfak Regency, West Papua Province. From the results of the research conducted, it was found that the dimensions of the runway length of Torea Airport have met the minimum requirements set by the International Civil Aviation Organization (ICAO) in 2016 with a runway length of 1201.8 m Torea Airport but in terms of requirements for the type of aircraft ATR 72-600 does not meet the requirements. While for the standard dimensions of the runway width and the width of the runway shoulder of Torea Airport according to the Regulation of the Ministry of Transportation of the Directorate General of Civil Aviation Number: KP 39 of 2015 concerning Technical and Operational Standards of Civil Aviation Safety Regulations
Bearing Capacity Analysis of Bridge Foundation Based on Cone Penetration Test Data and Soil Parameters Data Muhammad Yunus; Zahrin F. Syahdinar
Logic : Jurnal Rancang Bangun dan Teknologi Vol 19 No 3 (2019): November
Publisher : Pusat Penelitian dan Pengabdian kepada Masyarakat (P3M) Politeknik Negeri Bali

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (2712.631 KB) | DOI: 10.31940/logic.v19i3.1471

Abstract

One that deserves the attention of planners in designing a bridge structure is the design of the substructure. This is due to the fact that the structure below determines the quality and service life of a bridge and at present many cases of bridge structure failures are caused by failures of the substructure in holding the load acting on the bridge The aim of this research to test the characteristics of the soil and calculate bearing capacity of the foundation based cone penetration testing data and soil parameters at the Aifa bridge construction field in Fafurwar District, Teluk Bintuni Regency, West Papua Province. From the results of testing the soil characteristics in the laboratory, the type of soil at point 1 is the type of good to bad graded sand soil (SW-SP) with a water content of 17.72%, specific gravity 2.98, liquid limit (LL) = 16,746% included in the non-plastic category. While the location of point 2 is obtained from good to bad graded sand soil type (SW-SP) with a water content of 28.52%, specific gravity 2.73, liquid limit (LL) = 16.746% including the non-plastic category. To analysis of the calculation of the bearing capacity of the foundation Aifa bridge using data from the sondir test results for point 1 was obtained allowable bearing capacity (Qall) is 4.610,44 kN and for point 2 was obtained allowable bearing capacity (Qall) is 3.598,43 kN. For calculating bearing capacity of the foundation using soil parameter data for point 1 was obtained bearing capacity allowable (Qall) is 2.209,93 kN and for point 2 was obtained allowable bearing capacity (Qall) is 655,41 kN
PENGARUH PENAMBAHAN KAPUR TERHADAP NILAI PLASTISITAS TANAH LEMPUNG DI KABUPATEN FAKFAK PROPINSI PAPUA BARAT Muhammad Yunus; Irwan Rauf
Logic : Jurnal Rancang Bangun dan Teknologi Vol 18 No 1 (2018): March
Publisher : Pusat Penelitian dan Pengabdian kepada Masyarakat (P3M) Politeknik Negeri Bali

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (425.968 KB) | DOI: 10.31940/logic.v18i1.785

Abstract

Stabilisasi tanah dengan menggunakan kapur merupakan salah satu metode stabilisasi tanah kimiawi yang paling populer dan paling banyak digunakan di Indonesia, hal ini disebabkan material kapur yang tidak susah diperoleh dan harganya relatif murah. Kondisi jalan di daerah Kabupaten Fakfak banyak mengalami kerusakan, hal ini berkaitan dengan kondisi tanah dasar (subgrade) jalan yang berupa lapisan tanah lempung. Salah satu jenis tanah lempung yang tidak memenuhi syarat adalah tanah lempung yang memiliki nilai plastisitas yang tinggi, karena memiliki potensi pengembangan yang besar dan daya dukung yang rendah. Penelitian ini bertujuan untuk menentukan nilai plastisitas tanah lempung di Kabupaten Fakfak yang telah ditambahkan dengan kapur dengan persentase kapur sebesar 4%, 8% dan 12%. Hasil pengujian menunjukkan tanah lempung di Kabupaten Fakfak yang telah ditambahkan dengan campuran kapur sebesar 4% diperoleh nilai batas cair (LL) = 13.45%, batas plastis (PL) = 11.88% dan nilai Indeks Plastisitas (PI) = 0.17%. Untuk campuran kapur sebesar 8% diperoleh nilai batas cair (LL) = 23.76%, batas plastis (PL) = 19.85% dan nilai Indeks Plastisitas (PI) = 3.91%. Sedangkan campuran kapur sebesar 12% diperoleh nilai batas cair (LL) = 25.16%, batas plastis (PL) = 16.20% dan nilai Indeks Plastisitas (PI) = 9.28%.
STUDI EKSPERIMENTAL KUAT TEKAN BETON YANG MENGGUNAKAN PASIR LAUT SEBAGAI AGREGAT HALUS DI KABUPATEN FAKFAK PROVINSI PAPUA BARAT Imran Imran; Muhammad Yunus
INOVTEK POLBENG Vol 7, No 2 (2017): INOVTEK Volume 7, No 2, November 2017
Publisher : POLITEKNIK NEGERI BENGKALIS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (174.212 KB) | DOI: 10.35314/ip.v7i2.227

Abstract

Penggunaan agregat halus di Kabupaten Fakfak sebagai penyusun campuran beton untuk pekerjaan konstruksi secara umum masih tergantung pada pasir laut yang potensinya cukup besar. Penelitian ini bertujuan untuk; 1) mengetahui karakteristik pasir laut dan Pasir Sungai ; 2) mengetahui kuat tekan beton yang dihasilkan dari pasir laut dan pasir sungai pada pengujian 3, 7 dan 28 hari. Penelitian ini merupakan penelitian laboratorium berbasis sampel dan analisis karakteristik agregat dan uji tekan beton. Pasir laut Jalan Baru/Reklamasi, pasir sungai Palu dan pasir laut Kampung Seberang secara umum memenuhi persyaratan pengujian karakteristik agregat, namun demikian pasir yang paling baik digunakan adalah pasir laut Jalan Baru/Reklamasi dengan modulus kehalusan 2.183 dan masuk zone 2 (pasir agak kasar). Kuat tekan beton yang paling tinggi dari umur awal beton sampai akhir diperoleh dari pasir laut jalan Baru/Reklamasi dengan kuat tekan sebesar 93.86 kg/cm2 (umur beton 3 hari), 130.57 kg/cm2 (umur beton 7 hari), dan 172.61 kg/cm2 ( umur beton 28 hari). Sedangkan kuat tekan beton paling rendah pada umur awal beton (umur beton 3 dan 7 hari) diperoleh dari pasir sungai Palu, dengan kuat tekan sebesar 65.34 kg/cm2 (umur beton 3 hari), 101.20 kg/cm2 (umur beton 7 hari) dan 141.74 kg/cm2 (umur beton 28 hari). Kata Kunci- Pasir Laut, Pasir Sungai, Kuat Tekan Beton
KAJIAN PENENTUAN NILAI CBR TANAH MENGGUNAKAN DYNAMIC CONE PENETROMETER PADA PEMBANGUNAN RUAS JALAN MAMBRUK-KADAMBER KABUPATEN FAKFAK Muhammad Yunus; La Resky H. Nurfafen; M. Afdal R. Rum
Wahana Teknik Sipil: Jurnal Pengembangan Teknik Sipil Vol 27, No 2 (2022): Wahana Teknik Sipil
Publisher : Politeknik Negeri Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32497/wahanats.v27i2.4139

Abstract

In the road planning, one of the parameters needed is the value of California Bearing Ratio (CBR). the value of CBR is used as a parameter to determine the condition of the subgrade. The study was conducted to determine the CBR value and the percentage of the subgrade bearing capacity criteria on the Mambruk�Kadamber road, Fakfak Regency, West Papua. The method used in this study is a field survey using a Dynamic Cone Penetrometer (DCP) on a 1,9 km long track and divided every 50 meters so that the number of test points is 40 points, then the test data are analyzed using the PUPR and Kleyn methods. From the results of the analysis, the largest CBR value is 31,43% and the smallest 4,66% if analyzed using the PUPR method and when using the Kleyn method the largest CBR value is 22,23% and the smallest 3,51% with the avarege difference between both method is 3,27%. It is also known that as many as 10% of points still have poor soil bearing capacity criteria
PELATIHAN PENYUSUNAN RAB (RENCANA ANGGARAN BIAYA) BAGI APARAT KAMPUNG SEKBAN DISTRIK PARIWARI KABUPATEN FAKFAK PROVINSI PAPUA BARAT Yunus, Muhammad; Muhlisah, Nurul; Patanduk, James; Lomo, Supriyani
JCES (Journal of Character Education Society) Vol 6, No 1 (2023): Januari
Publisher : Universitas Muhammadiyah Mataram

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31764/jces.v6i1.11636

Abstract

bstrak: Saat ini pembangunan infrastruktur sangat masif dilakukan tidak terkecuali di daerah-daerah pelosok. Hal ini tidak terlepas dengan adanya kebijakan pembangunan infrastruktur yang dapat menggunakan Dana Kampung. Keberhasilan pembangunan infrastruktur di kampung sangat dipengaruhi pada tahap perencanaan dan salah satu luaran pada tahap perencanaan adalah dokumen Rencana Anggaran Biaya (RAB) pembangunan infrastruktur. Kegiatan yang dilaksanakan berupa pemberian pelatihan penyusunan Rencana Anggaran Biaya (RAB) kepada aparat kampung di Kampung Sekban. Pelaksanaan kegiatan terdiri dari tahap pengenalan gambar kerja dan Rencana Anggaran Biaya (RAB), perhitungan volume pekerjaan, analisa harga satuan pekerjaan, analisa kebutuhan bahan, penyusunan Rencana Anggaran Biaya (RAB) dan, rekapitulasi Rencana Anggaran Biaya (RAB). Luaran  kegiatan yang  diharapkan  adalah  tersusunnya  modul penyusunan anggaran  biaya sederhana yang dapat digunakan oleh aparat kampung dalam rangka kegiatan perencanaan pembangunan infrastruktur di kampung. Selain itu, melalui pelaksanaan kegiatan ini diharapkan dapa membantu meningkatkan pemahaman aparat kampung dalam menyusun Rencana Anggaran Biaya (RAB) infrastruktur kampung.Abstract:  Currently, massive infrastructure development is being carried out, including in remote areas. This is inseparable from the existence of infrastructure development policies that can use the Village Fund. The success of infrastructure development in the village is strongly influenced at the planning stage and one of the outputs at the planning stage is the Cost Estimating Plan (RAB) document for infrastructure development. The activities carried out were in the form of providing training on the preparation of the Cost Estimating Plan (RAB) to village officials in Sekban Village. The implementation of activities consists of the introduction of working drawings and Cost Estimating Plan (RAB), calculation of work volume, analysis of work unit prices, analysis of material requirements, preparation of Cost Estimating Plan (RAB) and, recapitulation of Cost Estimating Plan (RAB). The expected output of the activity is the compilation of a simple cost budgeting module that can be used by village officials in the context of infrastructure development planning activities in the village. In addition, through the implementation of this activity, it is hoped that it can help improve the understanding of village officials in preparing the Village Infrastructure Cost Estimating Plan (RAB).
A Kajian Nilai CBR Tanah Dasar Landasan Pacu Pesawat dengan Pengujian CBR Lapangan Yunus, Muhammad; Muhlisah, Nurul; Wicaksono, Catur; Aditya, Fahira
Siklus : Jurnal Teknik Sipil Vol. 10 No. 1 (2024): Siklus: Jurnal Teknik Sipil
Publisher : Program Studi Teknik Sipil Fakultas Teknik Universitas Lancang Kuning

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31849/siklus.v10i1.15248

Abstract

Salah satu faktor yang sangat penting untuk diperhatikan dalam perencanaan perkerasan landasan pacu bandar udara adalah daya dukung tanah dasar yang baik. Daya dukung tanah dasar pada perkerasan struktur landasan pacu menggunakan parameter berupa nilai CBR. Dalam menentukan daya dukung tanah dasar ini, salah satu metode pengujian yang banyak digunakan yaitu dengan metode pengujian CBR lapangan. Metode ini dipilih karena memiliki tingkat keakuratan yang lebih tinggi dibandingkan metode yang lain. Tujuan penelitian adalah untuk menentukan dan menganalisis nilai CBR tanah dasar pada pembangunan landasan pacu Bandar Udara Siboru melalui pengujian CBR lapangan. Dalam penelitian diambil sampel sepanjang 500 m dengan jumlah titik pengujian sebanyak 10 titik. Metode pengujian yang digunakan mengacu pada ASTM D4229 – 09 dan SNI 1738:2011. Dari hasil penelitian di peroleh nilai CBR tanah dasar terendah sebesar 12,02% dan nilai CBR tertinggi sebesar 24,40%. Kesimpulan yang diperoleh dari hasil analisis dan evaluasi nilai CBR bahwa tanah dasar memiliki kategori high (A) dengan interval nilai CBR ≥ 13% pada 8 titik pengujian dan kategori medium (B) dengan interval nilai CBR 8% < CBR < 13% pada 2 titik pengujian.
Pengaruh Penambahan Abu Batu (Fly Ash) Terhadap Plastisitas Tanah Lempung Di Kabupaten Fakfak Muhammad Yunus; Muhammad Aswan
Jurnal Poli-Teknologi Vol. 19 No. 1 (2020)
Publisher : Politeknik Negeri Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32722/pt.v19i1.2731

Abstract

The road conditions in the Fakfak Regency area have suffered a lot of damage, this is related to the subgrade condition of the road in the form of clay. One method that is widely used to improve the characteristics of clay that does not fulfill the requirements as a road subgrade material is to add fly ash. Aim of this study was to determine the value of clay plasticity before and after adding rock ash with the percentage of stone ash 8%, 16%, 32%. From the results of testing on clay soaked for 7 days can reduce the liquid limit value where the largest decrease is 15,24% of the original soil occurs in the addition of 32% fly ash with a value of 66,86%. The plastic limit value also decreased by 20,40% from the original soil with a value of 46,10% at the addition of 32% fly ash. And the plasticity index value experienced the largest decrease in the addition of 32% stone ash with a decrease of 0,97% from the original soil with a value of 20,76%. In clay soil which was brooded for 14 days the largest liquid limit value decreased which was 18.72% of the original soil occurred in the addition of 32% fly ash with a value of 64,11%. The plastic limit value also decreased by 21,77% from the original land with a value of 45,31% at the addition of 32% fly ash. And the plasticity index value experienced the largest decrease in the addition of 32% stone ash with a decrease of 10,32% from the original land with a value of 18,80%.