Found 7 Documents
Search

Harmonic Impact in Induction Generator Voltage Using Thyristor Control Reactor Suprihardi Suprihardi; Yaman Yaman; Zamzami Zamzami; Nelly Safitri
TELKOMNIKA (Telecommunication Computing Electronics and Control) Vol 16, No 3: June 2018
Publisher : Universitas Ahmad Dahlan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12928/telkomnika.v16i3.7788

Abstract

As commonly known that theload fluctuations that have been performed on an induction motor operated as an induction generator (IG) triggers unstable induced voltage and frequency. Asthe result, the load that receiving the power quality is not running properly and the efficiency is low. The problems that have beenmitigated in this research in such way is the stability of the voltage that generated by IG due to fluctuating loading, and the harmonics can be damped by single tuned due to the work of thyristors and non-linear loads. The used method is the Ziegler-Nichols method by measuring and testing the design of prototype to get the best performance in stabilizing the voltage by using thyristor control reactor (TCR). The results showed that the induced generator with single tuned filter and TCR to nonlinear load variation at 1618 RPM is maintained stably for the voltage and frequency. Although, 3rd order harmonics of voltage and current that has been tuned can be dampedby using THDI 8.36%. Furthermore, it can be said that the response that generated by voltage control system using proportionalintegral (PI) control in 1kW-4 poles three-phase IG with additional and reductionalload generated a stable response.
Studi Sistem Pembangkit Listrik Tenaga Mikro Hidro Di Kampung Tingkem Kecamatan Blang Jerango Gayo Lues Said Aiyub; Yaman Yaman; Sayuti Sayuti
Jurnal Teknologi Vol 21, No 2 (2021): Oktober 2021
Publisher : Politeknik Negeri Lhokseumawe

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (290.295 KB) | DOI: 10.30811/teknologi.v21i2.2431

Abstract

Gayo Lues has an operational micro-hydro power plant in Tingkem Village, Blangjerango District, which provides lighting, piping, and electricity to the residents of Tingkem Village. Among the objectives of this study were to determine and investigate the potential of the Aih Tilis river, the discharge of the carrier channel, the volume of the tranquilizer tank, the flow of water through the pipe, and the amount of electricity generated. Transport lines, troughs, and tubing are measured and calculated in this process. The discharge obtained on the carrier line is 0.5304816 m3/s, which is equal to 5.3 liters per second. There are 72.4605 cubic meters of dry trough volume and 65.556 cubic meters of wet section volume in this experiment. When the micro-hydroelectric power plant in Tingkem is operating at full capacity, it generates 79.631 kW of electricity with a turbine efficiency value of 70 percent and a generator efficiency value of 75 percent.
STUDI AUDIT ENERGI LISTRIK PADA GEDUNG PUSKESMAS BANDA SAKTI Said Aiyub; Yaman Yaman; Teuku Hasannudin; Muhammad Al-Azhari
Jurnal Energi Elektrik Vol 7, No 2 (2018): Jurnal Energi Elektrik Volume 7 Nomor 2
Publisher : Universitas Malikussaleh

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/jee.v7i2.1057

Abstract

Saat ini kebutuhan energi listrik semakin meningkat seiring dengan pertambahan jumlah penduduk dan kemajuan teknologi serta informasi.LajuĀ  pertumbuhan ekonomi dan pertambahan penduduk sangat terkait dengan konsumsi energi yang terus meningkat. Manajemen energi di tanah air selama ini lebih memberikan prioritas pada penyediaan energi atau perluasan akses terhadap energi kepada masyarakat yang diwujudkan dalam peningkatan eksploitasi bahan bakar fosil atau pembangunan listrik pedesaan. Tujuan ini untuk mencari peluang-peluang untuk penghematan energi danĀ  penghematan biaya berdasarkan kondisi aktual di lapangan. Pada bangunan dengan luas 628 m2 audit energi dilakukan menggunakan alat ukur Power Q Plus MI2392 sebagai alat untuk mengukur energi listrik dan luxmeter sebagai alat untuk mengukur kuat cahaya. Hasil audit energi menunjukkan bahwa nilai IKE pada gedung Puskesmas Banda Sakti sebesar 3.453 kWH /tahun sedangkan kWH yang sesuai dengan rekomendasi oleh SNI 03-6196-2000 sudah berada di atas standar IKE, dimana untuk gedung rumah sakit 380 kWH/m2 per tahun.
Turbin Angin menggunakan Pipa PVC sebagai Pembangkit Tenaga Listrik dan Pengusir Hama Burung Pipit Yaman; Said Aiyub2; Subhan3; Taufik4; Nuraini5
Jurnal Serambi Engineering Vol. 9 No. 2 (2024): April 2024
Publisher : Faculty of Engineering, Universitas Serambi Mekkah

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The paddy fields are generally large expanses of land that are free of wind barriers, away from human settlements and power sources. Sparrows are one of the most common pests, which usually attack paddyfield in clusters. The researchers who use electronic equipment as controllers to produce output, sounds and electronic drives, use a power source from batteries. The wind turbine is one method of repelling sparrows and producing electricity, as the driving force for the sound-producing mechanical equipment, and the Nema17 motor as the generator for charging the battery. Paddy is grown seasonally so the wind turbine can be disassembled for use and for storage. Measurement of wind speed to determine blade length, with the help of Win & Wet website, blade design, power relationship characteristics with windspeed and turbine rotation were created. The blade length of 60 cm can produce the power of 40 W, with using a pulley belt timing ratio of 1: 3 can increase the dc direct voltage, the lowest is 4.23 volts at a wind speed of 1.08 m / s and the highest voltage is 14.97 volts at a wind speed of 3.4 m/s, can be utilised for charging 3.7 volt Li ion batteries.
Innovation of control valve motorization method for regulating turbine rotation in micro hydro generators Hardi, Supri; Safitri, Nelly; Yaman, Yaman; Radhiah, Radhiah; Jamaluddin, Jamaluddin
International Journal of Applied Power Engineering (IJAPE) Vol 14, No 1: March 2025
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijape.v14.i1.pp90-100

Abstract

The method of transferring the main load to the dummy load is still used in micro hydropower plants. Because the turbine and generator are constantly operating at maximum capacity, the load transfer system, also known as the electronic load control (ELC) system, is ineffective and inefficient. The researcher devised a method for controlling the pressure/flow rate on the branch pipe by using a control valve motorized (CVM). Control valve motorized (CVM) is responsible for the opening and closing of branch pipelines using an electric motor. The goal is to achieve voltage and frequency stability by using CVM to adjust the flow/pressure of water in the branch pipe. The method involves designing and testing the CVM system via a Pelton turbine module connected to the generator. The results of testing the Pelton turbine module with a pressure of 4 kg/cm2 on a 34-inch pipe show that the turbine rotates at 800 rpm. Brushless direct current (BLDC) generator with 12 poles and a Pelton turbine. The proportional integral derivative (PID) controller control parameters are calculated by the control system using the Nichols-Ziggler method, with tuning results of PB 130%, Ti 2.8 seconds, and Td 0.7 seconds. A frequency of 50 Hz and a voltage of 61 volts is produced by controlling the set point (SP) at 55% of the process variable (PV) and the manipulated variable (MV) to CVM at 38%, respectively. The conditions are implemented by varying the load on the system by connecting and disconnecting the load; the system remains stable for 5 seconds.
Pengujian Daya Balik pada Sinkronisasi Generator dengan Sumber Daya Sangat Besar (Infinite Bus) secara Otomatis menggunakan Multifunction Relay Tipe GCP-30 di Laboratorium Sistem Proteksi dan Distribusi Jurusan Teknik Elektro Yaman, Yaman; Hasanuddin, Teuku; Yassir, Yassir; Fahlevi, Reza Tri
Jurnal Litek : Jurnal Listrik Telekomunikasi Elektronika Vol. 19 No. 1 (2022): Jurnal Litek, March 2022
Publisher : Jurusan Teknik Elektro Politeknik Negeri Lhokseumawe

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (629.747 KB) | DOI: 10.30811/litek.v19i1.22

Abstract

Daya balik atau motoring adalah peristiwa berubahnya fungsi generator listrik menjadi motor listrik pada saat sinkronisasi generator. Perubahan ini diakibatkan oleh berbaliknya arah aliran daya. Pengamanan generator dari gangguan daya balik biasanya menggunakan reverse power relay, dengan proses sinkronisasi dilakukan secara manual menggunakan synchronoscope. Multifunction Relay tipe GCP-30 adalah alat yang dapat melakukan kedua hal tersebut secara bersamaan. Alat ini berfungsi untuk menyinkronisasi generator secara manual atau otomatis, yang dilengkapi dengan pengaman, termasuk gangguan dari daya balik. Pengujian dilakukan untuk mengetahui pengaruh daya balik terhadap perubahan parameter torsi, arus medan eksitasi generator, dan jumlah beban yang dilayani. Hasil dari pengujian torsi diperoleh bahwa perubahan torsi akan mengubah pembagian beban, yang akan mengakibatkan timbulnya daya balik yang berlebih. Multifunction Relay tipe GCP-30 akan trip pada saat daya balik bernilai -67 W jika di set -8%. Hasil dari pengujian perubahan arus medan eksitasi generator adalah tidak adanya daya balik, tetapi generator akan berubah menjadi beban reaktif. Daya reaktif bernilai -441 VAR pada saat arus eksitasi bernilai 0 A. Adapun hasil dari pengujian perubahan beban adalah bertambah atau berkurangnya daya akan ditanggung oleh sumber daya yang lebih besar, yaitu daya dari sistem.
Pelatihan Praktikum Sistem Kontrol Kecepatan Motor Listrik Berbasis PID untuk Meningkatkan Kompetensi Siswa SMK Negeri 5 Lhokseumawe Yassir Yassir; Muhammad Basyir; Ipan Suandi; Aidi Finawan; Jamaluddin Jamaluddin; Zamzami Zamzami; Yaman Yaman; Muhammad Akbar Ramzil Ramzil
Jurnal Vokasi Vol 10, No 2 (2026): Juli
Publisher : Politeknik Negeri Lhokseumawe

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30811/vokasi.v10i2.9581

Abstract

Perkembangan teknologi sistem kontrol dan otomasi industri menuntut lulusan pendidikan vokasi memiliki kompetensi yang sesuai dengan kebutuhan dunia kerja. Berdasarkan hasil identifikasi kebutuhan di SMK Negeri 5 Lhokseumawe, pembelajaran sistem kontrol masih menghadapi keterbatasan media praktikum sehingga peserta didik belum memperoleh pengalaman yang memadai dalam mengimplementasikan teknologi kontrol modern. Kegiatan pengabdian kepada masyarakat ini bertujuan meningkatkan pengetahuan dan keterampilan siswa melalui pelatihan praktikum sistem kontrol kecepatan motor listrik berbasis Proportional-Integral-Derivative (PID). Pelatihan dilaksanakan selama dua hari di Laboratorium Instrumentasi dan Sistem Kendali Jurusan Teknik Elektro Politeknik Negeri Lhokseumawe dengan melibatkan enam siswa. Metode pelaksanaan meliputi penyampaian materi, demonstrasi, praktikum implementasi pengontrol PID, serta evaluasi menggunakan pre-test dan post-test. Hasil evaluasi menunjukkan bahwa rata-rata nilai peserta meningkat dari 45,67 pada pre-test menjadi 82,17 pada post-test, dengan peningkatan rata-rata sebesar 36,50 poin. Pengujian menggunakan paired t-test menghasilkan nilai thitung sebesar 16,14, lebih besar daripada ttabel sebesar 2,571 pada taraf signifikansi 5%, sehingga peningkatan kompetensi peserta dinyatakan signifikan secara statistik. Hasil tersebut menunjukkan bahwa pelatihan berhasil meningkatkan pemahaman konseptual dan keterampilan praktis peserta dalam mengimplementasikan sistem kontrol kecepatan motor listrik berbasis PID. Dengan demikian, pelatihan praktikum berbasis PID dapat menjadi salah satu bentuk kegiatan pengabdian kepada masyarakat yang efektif dalam mendukung peningkatan kompetensi siswa pendidikan vokasi.