Kusnindar Abd. Chauf
Unknown Affiliation

Published : 6 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 6 Documents
Search

Perilaku Lentur Balok Glulam Dengan Variasi Gaya Kempa Chauf, Kusnindar A
SMARTek Vol 3, No 2 (2005)
Publisher : SMARTek

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (302.592 KB)

Abstract

Untuk mengetahui pengaruh intensitas pengempaan terhadap perilaku lentur balok glulam, maka perlu dilakukan pengujian lentur dengan variasi gaya kempa. Dalam hal ini variasi yang diterapkan adalah 0,6, 1,2, 3, 6, 9 dan 12 Mpa, dengan dimensi balok 5,5/11,5 dan bentang 180 cm. Hasil pengujian menunjukkan r = 0,599 g/cm3, t//rekatan= 1,094t//, MOR = 89,989 MPa, dan MOE = 12395 MPa. Dengan spesifikasi demikian, maka variasi pengempaan untuk aplikasi balok glulam cenderung menunjukkan fluktuasi besaran mekanik menurut kenaikan intensitas gaya kempa. Titik optimum dicapai pada pengempaan 0,3t// untuk optimalisasi kapasitas lentur dan > 0,3 t// untuk optimalisasi kekakuan. Makin tinggi intensitas pengempaan maka momen internal dan kelengkungan yang tercapai juga cenderung semakin tinggi
Perilaku Geser Balok Kayu Kelapa (Suatu Kajian Eksperimental dengan Konsep Energi Fracture) Oktivina, Hermin; Chauf, Kusnindar A.
JOURNAL TEKNIK SIPIL DAN INFRASTRUKTUR Vol 1, No 1 (2011)
Publisher : Jurusan Teknik Sipil Universitas Tadulako

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1424.859 KB)

Abstract

Analisis karakteristik kayu perlu didekatkan pada kondisi material non-homogen dengan menerapkan konsepenergi fracture. Konsep energi fracture menjelaskan adanya energi elastisitas dan potensial yang mempegaruhi dimensiretak. Konsep ini sangat relevan diaplikasikan pada material kayu kelapa, karena kayu kelapa tersusun dari serat sejajarlongitudinal yang cenderung gagal geser. Dari hasil uji sifat fisis dan mekanis menurut ISO 1975 dan uji lentur balokempat titik, maka dilakukan analisis pola deformasi terhadap kurva deformasi berdasarkan konsep energi fracture.Dalam hal ini diperoleh fakta bahwa kerapatan kayu kelapa berturut-turut, bagian atas 0,64 gr/cm3, bagian tengah 0,83gr/cm3dan bagian bawah 0,91 gr/cm3 dengan kurva deformasi elastis non linear, kecuali tarik sejajar serat.Perbandingan tegangan geser dan lentur balok adalah 9,76% dengan keruntuhan geser. Pola kerusakan geser ditandaiadanya retak horizontal dimulai dari tumpuan kemudian merambat kearah tengah bentang balok, dan tegangan gesermaksimum lebih dulu tercapai daripada tegangan lentur
Pengaruh Posisi Sambungan Lamina Terhadap Kapasitas Lentur Balok Kayu Laminasi Chauf, Kusnindar A.
JOURNAL TEKNIK SIPIL DAN INFRASTRUKTUR Vol 2, No 1 (2012)
Publisher : Jurusan Teknik Sipil Universitas Tadulako

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (475.695 KB)

Abstract

Balok laminasi memiliki fleksibilitas dan efisiensi dalam hal pencapaian bentang. Sehubungan dengan itu perlu diketahui efek sambungan terhadap kapasitas lentur balok, agar diperoleh parameter desain yang akomodatif terhadap perlemahan sambungan. Dalam hal ini dasar pengaturan formasi dan komposisi sambungan yang diterapkan adalah kondisi tegangan lentur dan pola penyebaran retak longitudinal yang mungkin terjadi. Melalui uji kerapatan dan sifat mekanik spesimen kecil kayu kamper menurut ISO. 1975 diperoleh acuan untuk penentuan dimensi balok lentur. Berdasarkan konsep energi fracture diterapkan formasi sambungan 100% berupa scarft joint (l/h =3,333) pada balok, kemudian dilakukan uji lentur statik empat titik dengan enam variasi formasi sambungan yaitu BS.0, BS.10A, BS.10B, BS.13A, BS.13B dan BS.26 untuk memperoleh data beban-lendutan, yang kemudian dijadikan dasar penentuan prilaku lentur balok kayu laminasi.Pengaplikasian formasi 100% scarft-joint (l/h = 3,333) dengan jarak minimal 2,125h menyebabkan reduksi kapasitas lentur (MOR) balok kayu laminasi maksimum 34,6% pada BS.13A dan minimum 25% pada BS.10B. Selain itu juga terjadi reduksi kekakuan (MOE) maksimum 29,7% pada BS.13A dan minimum 8,6% pada BS.13B. Perlemahan akibat sambungan sangat diditentukan oleh tebal dan kemiringan garis perekat serta jumlah dan formasi sambungan yang diterapkan
KARAKTERISTIK MEKANIK KAYU KAMPER SEBAGAI BAHAN KONSTRUKSI Chauf, Kusnindar A.
MEKTEK Vol 7, No 1 (2005)
Publisher : MEKTEK

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (436.083 KB)

Abstract

Mechanic characteristic is needed for efficiency and optimalization of wood as structural member, so that it can be placed in order of construction. By conducting mechanics test refered to ISO 1975, it could be examined a mechanics characteristics of wood as a base of structural aplication. In this case the flexure strength capacity (MOR) is 89.989 MPa and flexure elasticity (MOE) is 13260 MPa. Parallel tension strength (s//), parallel compression strength (stk//), and shear strength (t//) are 126.913 MPa, 0.4s// and 10,913 MPa respectively. The type of collapse is elastic linier; the brittle collapse will be happened in tension on the otherhand elastics and non linier collapse will be happened in flexure, compression as well as shear. Average mechanic intencity of Kamper will increase if the water content is decrease and the highest increasing on the parallel compression capacity, i.e. 50,5% if it is compared to dried and green condition
STUDI PEMANFAATAN PARTIKEL KOMPOS UNTUK PEMBUATAN BATAKO RINGAN Maricar, Shyama; Chauf, Kusnindar Abd.
MEKTEK Vol 13, No 1 (2011)
Publisher : MEKTEK

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (678.758 KB)

Abstract

One effort to reduce the weight of the building is through the use of light particles in the concrete or mortar.For that particles of compost to be one alternative to be used. Utilization of compost particles directly willreduce the effects of environmental pollution due to garbage. Technically, in some cases the strength ofconcrete is not a determining factor but rather the ductility. Therefore in this study will be reviewed andfurther analyzed the mechanical properties of lightweight concrete that uses compost particles as basicmaterials. Mechanical properties and tensile strength referred to is the compressive strength, with normalmortar as a comparison.Based on the results of the weight of the material obtained gr/cm3 mortar respectively, cement 1.25, sand1.60, 0.31 and compost particles with water content 12%. In this case the effect of adding compost is adecrease in compressive strength of 48.74%, 68.78% decrease in tensile strength and weight reduction of9.85%. In this case the application in the manufacture of bricks is still possible, if based on a minimumcompressive strength requirement. The composition of lightweight concrete blocks with a mixture of 3%addition of compost particles are 2Semen: 6.25 Sand: 4Kompos: 2.5 water, which will produce concreteblocks with a weight of 1.89 gr/cm3 and compressive strength 7.7 MPa
PANEL BETON BERTULANGAN BAMBU SEBAGAI ALTERNATIF BAHAN KONSTRUKSI Maricar, Shyama; Hasan, Hajatni; Chauf, Kusnindar Abd.
MEKTEK Vol 14, No 3 (2012)
Publisher : MEKTEK

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1089.6 KB)

Abstract

The use of natural materials for construction purposes should be developed. Special reinforced concrete construction, in some cases, the compressive strength is not a determining factor, but rather ductility. On the other hand, bamboo is a natural material has a ductile properties sufficient to be used as reinforcement. For this type of bamboo lear, some properties that are important to note is the compressive strength , σ//= 39.89 MPa,  σ┴ = 5.55 MPa, Shear strength is 7.644 MPa  and tensile strength is 207.523 MPa. In addition, the physical properties of mortar material used is weight of contents of cement is 1.25 gr/cm3, weigtht ofcontent of sand is 1.60 gr/cm3.From the test results it can be concluded that the test samples for concrete mix bamboo panel with division 1 cement and 4 sand did not change significantly so that the maximum load obtained for testing age from 7 days to 21 days also resulted in maximum load that is not much different. Thus the utilization of bamboo reinforced concrete panels for the purpose of the wall can be done, although it still requires further development.