Design of a Reconfigurable, Modular and Multi-Channel Bioimpedance Spectroscopy System Ahmed Al-Hashimi; Anis Nurashikin Nordin; Amelia Wong Azman
Indonesian Journal of Electrical Engineering and Computer Science Vol 8, No 2: November 2017
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijeecs.v8.i2.pp428-440

Abstract

This paper presents the design and implementation of a multichannel bio-impedance spectroscopy system on field programmable gate arrays (FPGA). The proposed system is capable of acquiring multiple signals from multiple bio-impedance sensors, process the data on the FPGA and store the final data in the on-board Memory. The system employs the Digital Automatic Balance Bridge (DABB) method to acquire data from biosensors. The DABB measures initial data of a known impedance to extrapolate the value of the impedance for the device under test. This method offers a simpler design because the balancing of the circuit is done digitally in the FPGA rather than using an external circuit. Calculations of the impedance values for the device under test were done in the processor. The final data is sent to an onboard Flash Memory to be stored for later access. The control unit handles the interfacing and the scheduling between these different modules (Processor, Flash Memory) as well as interfacing to multiple Balance Bridge and multiple biosensors. The system has been simulated successfully and has comparable performance to other FPGA based solutions. The system has a robust design that is capable of handling and interfacing input from multiple biosensors. Data processing and storage is also performed with minimal resources on the FPGA.
Verification of Quartz Crystal Microbalance Array using Vector Network Analyzer and OpenQCM Ahmad Anwar Zainuddin; Anis Nurashikin Nordin; Rosminazuin Ab. Rahim; Aliza Aini Md. Ralib; Sheroz Khan; Cyril Guines; Matthieu Chatras; Arnaud Pothier
Indonesian Journal of Electrical Engineering and Computer Science Vol 10, No 1: April 2018
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijeecs.v10.i1.pp84-93

Abstract

Quartz Crystal Microbalance (QCM) is a device that allows non-destructive measurements of r in situ reaction activities. In this article, an array comprising of six 3MHz QCM sensors in an array were characterized using a vector network analyzer and OpenQCM, a portable measuring instrument that measures change in resonance frequency. Measurements of S21 transmission characteristics using the vector network analyzer provides the resonance frequency and can also be used to derive the RLC equivalent electrical circuit values of a resonant two-port network based on the Butterworth-Van Dyke model. In this work, Rm, Lm, Cm and Co were obtained via curve-fitting of the measurement results to the simulated results. Measurements were done in triplicates to verify reproducibility for all 6 sensors. For comparison, measurements were also done using a portable, open-source instrument, OpenQCM. The OpenQCM instrument directly measures changes in resonance frequencies, making it ideal for biosensing experiments, which correlate changes in mass with changes in resonance frequencies. Comparison between resonance frequency measurements using VNA and OpenQCM exhibit low percentage difference 0.2%.  This QCM sensor array has the potential of conducting real-time, point-of-care analyses for detection of biological molecules.