Baby Incubator Based on PID Control With Kangaroo Mode (Kangaroo Mode and Humidity) Nur Fildzah Hidayati; Endro Yulianto; Abd Kholiq
Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 1 No 2 (2019): October
Publisher : Department of Electromedical Engineering, POLTEKKES KEMENKES SURABAYA and IKATEMI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jeeemi.v1i2.3

Abstract

Baby Incubator is one of the electromedical equipment used to provide protection to premature babies or low birth weight. Baby care in the baby incubator causes separation of mother and baby. A new innovation in the care of premature babies who bring their babies and mothers closer is Kangaroo Method Management (PMK). Kangaroo method treatment aims to create emotional attachment to the baby, so that the mother will confidently take care. The research and manufacture of this module uses a method of treating baby incubator by adding a reading of the room temperature when the kangaroo mode runs at a setting of 34 ° C - 37 ° C with the effect of room temperature at 18 ° C, 24 ° C, and 30 ° C and setting the humidity control automatically by measuring at a temperature of 32 ° C, then measuring the results immediately. Sensors used to detect temperature are LM35 sensors and sensors used to detect humidity using DHT22. Based on the measurement results obtained uncertainty values ​​on the measurement of humidity 2.1, the measurement of temperature stability can be seen from the results of the graph which shows that the room temperature is not too influential at the temperature of the baby incubator. This study has shown the development of baby incubators to help mothers who have babies born prematurely so that they can have a good bond with how to treat skin to skin. This study has proven that its accuracy is appropriate to be used to stabilize the condition of babies born prematurely and help to treat PMK in some hospitals. In the future, this research can be made and used in small clinics in villages at low costs.
Syringe Pump With Nearly Empty Based Microcontroller Atmega328 Lely Erica Putri; Muhammad Ridha Mak'ruf; Abd Kholiq
Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 1 No 2 (2019): October
Publisher : Department of Electromedical Engineering, POLTEKKES KEMENKES SURABAYA and IKATEMI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jeeemi.v1i2.5

Abstract

Syringe Pump is a tool used to give liquid medicine or food liquid into the patient's body in a certain amount and within a certain period of time on a regular basis. The purpose of this study is to facilitate monitoring of fluid in the syringe so that the hose is not installed continuously when the liquid has run out. The circuit consists of an Atmega328 microcontroller, a motor driver, and an optocoupler sensor. Setting the syringe, volume and flowrate is done at the beginning. To insert liquid, the motor must be run by the way the settings have been done and press the start button. Tools need supply from PLN grids. Calibration is done using IDA 4 Plus. This tool is equipped with the addition of alarms nearly empty and the bolus button. From the measurements taken, at the 20 ml syringe the biggest error occurred at the 5 ml volume point of 0.4% and at the 50 ml syringe the biggest error occurred at the 5 ml volume point of 0.280%.This module can be used according to its function, because the% error is still below the ± 5% standard.