ANALISA PENGARUH SUDUT KEMIRINGAN SOLAR TRACKER SINGLE AXIS PADA PLTS BERBASIS IOT DAN REAL TIME CLOCK TERHADAP DAYA KELUARAN Fitriani Said; Abil Huda; Rezky Septiawan
Elektrika Borneo Vol 12, No 2 (2026): Elektrika Borneo Edisi Oktober
Publisher : Jurusan Teknik Elektro, Fakultas Teknik, Universitas Borneo Tarakan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35334/eb.v12i2.7080

Abstract

Pembangkit Listrik Tenaga Surya (PLTS) merupakan salah satu teknologi energi terbarukan yang memanfaatkan radiasi matahari untuk menghasilkan energi listrik. Kinerja modul surya sangat dipengaruhi oleh sudut kemiringan panel terhadap arah datangnya sinar matahari. Penelitian ini bertujuan menganalisis pengaruh variasi sudut kemiringan terhadap daya keluaran, serta membandingkan kinerja sistem statistik dengan sistem solar tracking berbasis Internet of Things (IoT) dan Real Time Clock (RTC). Metode penelitian meliputi pengukuran intensitas cahaya, tegangan, arus, dan daya keluaran pada panel statistik (sudut tetap) serta panel pelacakan (sudut mengikuti posisi matahari). Pengambilan data dilakukan dari pukul 07.00 hingga 18.00 WITA, kemudian hasil dibandingkan untuk menentukan sudut optimal. Hasil penelitian menunjukkan bahwa sudut kemiringan berpengaruh signifikan terhadap daya keluaran, dengan sudut optimal pada jarak 82,5°–112,5° dan puncak di 105°. Sistem solar tracking terbukti lebih efisien dibandingkan panel statis, dengan peningkatan efisiensi 5,8% pada hari pertama dan 7,98% pada hari kedua. Dengan demikian, penggunaan solar tracker mampu meningkatkan pemanfaatan energi surya secara lebih optimal.
PERANCANGAN SISTEM PEMBANGKIT LISTRIK TENAGA SURYA MENGGUNAKAN PVSYST DI GEDUNG LABORATORIUM SENTRAL ILMU HAYATI UNIVERSITAS BORNEO TARAKAN Abil Huda; Haslinda Haslinda
Elektrika Borneo Vol 11, No 2 (2025): Elektrika Borneo Edisi Oktober
Publisher : Jurusan Teknik Elektro, Fakultas Teknik, Universitas Borneo Tarakan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35334/eb.v11i2.6623

Abstract

The increasing need for energy encourages the use of renewable energy, one of which is solar energy. This study discusses the design of a rooftop PLTS system at the Central Laboratory of Life Sciences (LSIH) Building, Borneo Tarakan University. Using PVsyst software, the technical design of the system is simulated to adjust to the actual load needs of the building. The design results show the use of 32 250Wp solar modules and 2 inverters with a total output power of 8.2 kWh. This system is capable of supplying 8 kWh of power and producing energy up to 11,958 kWh/year.
DESAIN DAN SIMULASI BIDIRECTIONAL DC-DC CONVERTER PADA BATERAI SEBAGAI PENYIMPAN ENERGI DENGAN METODE KONTROL PWM Abil Huda; Ismit Mado; Anra Anra
Elektrika Borneo Vol 12, No 2 (2026): Elektrika Borneo Edisi Oktober
Publisher : Jurusan Teknik Elektro, Fakultas Teknik, Universitas Borneo Tarakan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35334/eb.v12i2.7544

Abstract

The utilization of renewable energy, such as Solar Power Plants (PLTS), faces intermittency challenges that require stable and efficient battery energy storage systems. This study focuses on the design and simulation of a bidirectional DC-DC converter as a key interface unit between the battery and the power distribution system. The novelty of this research lies in the optimization of Pulse Width Modulation (PWM) control schemes combined with current management algorithms to ensure efficient battery charging and discharging processes with low current ripple. The methodology involves power electronic circuit modeling, calculation of filter components based on switching frequency, and dynamic testing through MATLAB/Simulink simulations with varying duty cycles. During a 10-second charging period, the SoC increased from 50% to 50.07% with a charging current of 2.041 A and a battery voltage of 25.98 V, moving toward the full-charge voltage of 27.93 V. The negative current value indicates the direction of flow from the 48 V DC voltage source to the 24 V battery. During a 10-second discharge, the SoC dropped from 50% to 49.76%, with a discharge current of 9.189 A and a battery voltage of 25.32 V, moving toward the 18 V cut-off voltage. The positive current value indicates the direction of flow from the 24 V battery to the 48 V DC voltage source.
Performance Analysis of Three Phase Induction Motor at PT. Intracawood Manufacturing Linda Sartika; Abil Huda; Abdul Muis Prasetia; Lela Nofita Sari
JEEE-U (Journal of Electrical and Electronic Engineering-UMSIDA) Vol. 9 No. 1 (2025): April
Publisher : Muhammadiyah University, Sidoarjo

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21070/jeeeu.v9i1.1692

Abstract

To support the production process in an industry, there are many electric motor equipment in the form of induction motors. Induction motors are the most widely used motors in various fields, ranging from household environments to large-scale industries. Induction motors that are used continuously do not guarantee that they will always work normally, meaning that the motor can experience damage. These damages can affect the performance of the reduced induction motor. To find out the performance of the motor at PT. Intracawood Manufacturing, an analysis was carried out on the Blower Sander, Rotary, Conveyor Dry, and Conveyor Finishing motors, respectively on taking motor data based on the name plate and the motor in the current condition that was running or after rewinding. Motor performance analysis was conducted by calculating current, input power, output power, load torque, induction torque, and efficiency. From the calculation results, the Blower Sander motor by taking motor on the name plate with a current of 103 A, obtained an input power of 58.979 kW, an output power of 51.214 kW, an induction torque of 335.12 N.m, a load torque of 330.62 and efficiency of 86,83%. Meanwhile, the current motor condition with a current of 81.2 A, obtained input power of 43.945 kW, output power of 38.605 kW, induction torque of 254.7 N.m load torque of 250.23 N.m, and efficiency of 87.84%. Can be concluded, the performance of a three-phase induction motor at PT. Intracawood Manufacturing was a better is after rewinding.