Claim Missing Document
Check
Articles

Found 25 Documents
Search

PENGARUH KOLOM PASIR TERHADAP KONSOLIDASI TANAH LEMPUNG LUNAK Listyawan, Anto Budi; Wiqoyah, Qunik; Ningsih, Rena; Widhi Satriyana, Marten Widhi Satriyana Ramadlan
Eco Rekayasa Vol. 11. No.1, Maret 2015
Publisher : Universitas Muhammadiyah Surakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The  road weaving near Sragen city Central Java has been daily problem  in  last decade. The  existing of high expansive  clay soil in subgrade below the road foundation has been identified as the major cause of this problem. Sand Column become one solution to improve the subgrade since it can ab-sorb the water  from the void of clay soil and drain into the channel. The re-search develops a model of Sand column in laboratorium. The box of 1.0 m x 0.4 m x 0.4 m has been created. 15 cm diameter of sand column then installed at the toe and samples for consolidation test are taken from various distances from the centre of column (i.e. 16.67 cm; 33.33 cm; and 50 cm). The result shows that the Sand Column can improve the soft clay soil in terms of consolidation. The coefficient of consolidation increases as the compression index drops. Consequently, the consolidation settlement can be re-duced significantly.
TRAINING RENOVASI DAN PERAWATAN POMPA HIDRAM DI DESA KARANG PELEM, KECAMATAN KEDAWUNG, SRAGEN Sudjatmiko, Aliem; Wiqoyah, Qunik; Ujianto, Mohammad
WARTA WARTA Volume 10, Nomor 1, Maret 2007
Publisher : Universitas Muhammadiyah Surakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (52.896 KB) | DOI: 10.23917/warta.v10i1.3202

Abstract

Technological Pump the Hidram technology pump to use the basework style of grafitasi earth and designed in such a way till work the pumpwork automatically without there external energi for example energi oil.Constraint which often bother the [job/activity] pump the hidram  is notoptimal is component function pump the effect stuffing up of dirt andcomponent damage pump. The pump Hidram equiped some kinds ofspillway, for example functioning water spillway to arrange awaking ofcurrent and awaking of pressure irrigate the , air-trap to arrange awakingof air composition in water. Especial benefit air good for condition of[isnature of water from nature of water which incompresible become semiincompresible so that punching influence irrigate the/hummer water notdestroy the material pump specially save the tekan.Tabung depress tofunction to catch and maintain the yielded water pressure. Component pumpthe hidram consisted of the Reservoir concentration, fast pipe, spillway oflimbah,balance weight, air spillway, spillway depress and save to depressand also other supporter that is pipe between. In course of evaluation[done/conducted] repair problem of water spillway using rubber of vehiclerut/rubber konveyor, and if/when reckoned from a economic side pumpthis very efficient because energi used to create the pressure irrigate tocome from laboring earth gravitation style air.Benefit from spillway irrigateand also air spillway can be arranged in such a way till work the pump canwork automatically and will labour on during balance constraint workthe pump not annoyed. From repair result got a technical age spillwaymount and stay more 6 month;moon and loss / water leakage causing tolessen the pressure can be avoided. To the condition of in such a way tillwork the pump automatically [done/conducted] a trial and error
PENGARUH KOLOM PASIR TERHADAP KONSOLIDASI TANAH LEMPUNG LUNAK Listyawan, Anto Budi; Wiqoyah, Qunik; Ningsih, Rena; Widhi Satriyana, Marten Widhi Satriyana Ramadlan
Eco Rekayasa: Jurnal Teknik Sipil Vol. 11. No.1, Maret 2015
Publisher : Universitas Muhammadiyah Surakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The  road weaving near Sragen city Central Java has been daily problem  in  last decade. The  existing of high expansive  clay soil in subgrade below the road foundation has been identified as the major cause of this problem. Sand Column become one solution to improve the subgrade since it can ab-sorb the water  from the void of clay soil and drain into the channel. The re-search develops a model of Sand column in laboratorium. The box of 1.0 m x 0.4 m x 0.4 m has been created. 15 cm diameter of sand column then installed at the toe and samples for consolidation test are taken from various distances from the centre of column (i.e. 16.67 cm; 33.33 cm; and 50 cm). The result shows that the Sand Column can improve the soft clay soil in terms of consolidation. The coefficient of consolidation increases as the compression index drops. Consequently, the consolidation settlement can be re-duced significantly.
Sudut Tenang Tanah Pasir-Lempung Pada Kondisi Runtuh Anto Budi Listyawan; Renaningsih Renaningsih; Qunik Wiqoyah; Aditya Galih Pradana
Borneo Engineering : Jurnal Teknik Sipil Volume 4 Nomor 2 Tahun 2020
Publisher : Jurusan Teknik Sipil, Fakultas Teknik, Universitas Borneo Tarakan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35334/be.v4i2.1441

Abstract

The soil layer is the combination of many types as well as the soil in the slope area. The soil in the slope is frequently a mixture of clay and sand. The stability of slope becomes dominantly an issue in the geotechnical engineering area. The collapse of the slope occurs because the gravity of external forces is exceeding the shear strength of the soil. The recent research develops the apparatus to determine the angle of repose of the sand-clay soil in the failure conditions. Sandy soil is taken from Beach and Merapi volcano. The clay added into the sand in the proportion of 0%, 5%, 10%, 15%, 20%, 25%, and 30%. The experiment is conducted by taking the height of the falling material of 15cm, 25cm, and 35 cm. Adding 0% to 15% clay brings the sand into SP Category, then adding 20%-30% makes the sand in the SC category. The Modulus if a fine grain of sand beach is smaller than Merapi sand. As the percentage of clay added to the sand higher, the difference of angle of repose of Merapi sand before and after failure is getting smaller, but it is not the case in Beach sand. The percentage of loss of volume of Merapi sand after failure is also going down as the portion of clay higher. The loss of volume of Beach sand added by clay is getting higher in failure condition..
DRAINASE VERTIKAL DENGAN KOLOM CAMPURAN PASIR-PECAHAN BETON UNTUK MEMPERCEPAT KONSOLIDASI TANAH LEMPUNG Anto Budi Listyawan; Qunik Wiqoyah; Sugiyatno; M. Alaydrus Guntur Pamungkas4
JURNAL REKAYASA Vol 10 No 2 (2020): Jurnal REKAYASA
Publisher : Fakultas Teknik Sipil dan Perencanaan. Universitas Bung Hatta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37037/jrftsp.v10i2.61

Abstract

Tanah di Desa Troketon, Kecamatan Pedan, Kabupaten Klaten mempunyai nilai PI sebesar 34,59%; LL 62,55%; PL 27,96%; dan SL 19.62% ditinjau dengan metode USCS (United Soil Clasification System) termasuk ke dalam kelompok golongan CH yaitu lempung anorganik berplastisitas tinggi. Tanah lempung yang buruk dapat mengakibatkan rusaknya bangunan di atasnya seperti jalan yang bergelombang. Tanah lempung yang buruk dapat diperbaiki menggunakan drainase vertikal yang bertujuan untuk mempercepat penurunan sehingga waktu yang dihabiskan untuk pembangunan relatif singkat dan tidak memakan biaya yang berlebih. Pada penelitian drainase vertikal ini digunakan kolom campuran pasir dan pecahan beton dengan variasi susunan kolom pola bujur sangkar dan segitiga. Sampel diambil pada titik tengah antar 4 kolom , 3 kolom dan 2 kolom, kemudian dilakukan pengujian konsolidasi. Pada variasi bujur sangkar titik tengah antar 4 kolom didapatkan nilai CV sebesar 0,000187 cm2/s, CC sebesar 0.429 dan SC sebesar 0.173 sedangkan, titik tengah antar 2 kolom mempunyai CV sebesar 0,000163 cm2/s, CC sebesar 0.490 dan SC sebesar 0.176. Pada variasi segitiga titik tengah antar 3 kolom didapatkan nilai CV sebesar 0.000129 cm2/s, CC sebesar 0.541 dan SC sebesar 0.254 sedangkan, titik tengah antar 2 kolom mempunya nilai CV sebesar 0.000114 cm2/s, CC sebesar 0.561 dan SC sebesar 0.258. Sehingga kolom campuran pasir dan pecahan beton dengan variasi bujur sangkar lebih baik untuk digunakan sebagai drainase vertikal.
TRAINING RENOVASI DAN PERAWATAN POMPA HIDRAM DI DESA KARANG PELEM, KECAMATAN KEDAWUNG, SRAGEN Aliem Sudjatmiko; Qunik Wiqoyah; Mohammad Ujianto
WARTA LPM WARTA Volume 10, Nomor 1, Maret 2007
Publisher : Universitas Muhammadiyah Surakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23917/warta.v10i1.3202

Abstract

Technological Pump the Hidram technology pump to use the basework style of grafitasi earth and designed in such a way till work the pumpwork automatically without there external energi for example energi oil.Constraint which often bother the [job/activity] pump the hidram  is notoptimal is component function pump the effect stuffing up of dirt andcomponent damage pump. The pump Hidram equiped some kinds ofspillway, for example functioning water spillway to arrange awaking ofcurrent and awaking of pressure irrigate the , air-trap to arrange awakingof air composition in water. Especial benefit air good for condition of[isnature of water from nature of water which incompresible become semiincompresible so that punching influence irrigate the/hummer water notdestroy the material pump specially save the tekan.Tabung depress tofunction to catch and maintain the yielded water pressure. Component pumpthe hidram consisted of the Reservoir concentration, fast pipe, spillway oflimbah,balance weight, air spillway, spillway depress and save to depressand also other supporter that is pipe between. In course of evaluation[done/conducted] repair problem of water spillway using rubber of vehiclerut/rubber konveyor, and if/when reckoned from a economic side pumpthis very efficient because energi used to create the pressure irrigate tocome from laboring earth gravitation style air.Benefit from spillway irrigateand also air spillway can be arranged in such a way till work the pump canwork automatically and will labour on during balance constraint workthe pump not annoyed. From repair result got a technical age spillwaymount and stay more 6 month;moon and loss / water leakage causing tolessen the pressure can be avoided. To the condition of in such a way tillwork the pump automatically [done/conducted] a trial and error
PENGARUH KOLOM PASIR TERHADAP KONSOLIDASI TANAH LEMPUNG LUNAK Anto Budi Listyawan; Qunik Wiqoyah; Rena Ningsih; Marten Widhi Satriyana Ramadlan Widhi Satriyana
Eco Rekayasa: Jurnal Teknik Sipil Vol. 11. No.1, Maret 2015
Publisher : Universitas Muhammadiyah Surakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The  road weaving near Sragen city Central Java has been daily problem  in  last decade. The  existing of high expansive  clay soil in subgrade below the road foundation has been identified as the major cause of this problem. Sand Column become one solution to improve the subgrade since it can ab-sorb the water  from the void of clay soil and drain into the channel. The re-search develops a model of Sand column in laboratorium. The box of 1.0 m x 0.4 m x 0.4 m has been created. 15 cm diameter of sand column then installed at the toe and samples for consolidation test are taken from various distances from the centre of column (i.e. 16.67 cm; 33.33 cm; and 50 cm). The result shows that the Sand Column can improve the soft clay soil in terms of consolidation. The coefficient of consolidation increases as the compression index drops. Consequently, the consolidation settlement can be re-duced significantly.
Perencanaan Fondasi Tiang Pancang Pada Gedung Perkuliahan Universitas Slamet Riyadi (Variasi Diameter Tiang Pancang) Qunik Wiqoyah; Iwan Setyo Nugroho
Dinamika Teknik Sipil: Majalah Ilmiah Teknik Sipil Vol. 15/No.1/Juli 2022
Publisher : Departement of Civil Engineering, Faculty of Engineering

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (371.428 KB) | DOI: 10.23917/dts.v1i1.18525

Abstract

Uji sondir dilakukan pada 3 titik di lokasi pembangunan Gedung perkuliahan Universitas Slamet Riyadi. Didapatkan bahwa tanah keras terletak pada kedalaman 4,4 m dari permukan tanah. Berdasarkan hasil uji sondir tersebut maka jenis fondasi yang digunakan dalam perencanaan ini adalah pondasi tiang pancang beton dengan 3 jenis variasi diameter yaitu dengan diameter 0,3; 0,4; 0,5 m dengan kedalaman tiang 4 m. Tujuan dari perencanaan ini adalah menentukan beban struktur yang diterima oleh fondasi, mendesain jumlah tiang pancang yang dibutuhkan, mendesain penulangan pada Pile Cap serta penulangan tiang pancang. Perencanaan diawali dengan menentukan beban struktur yang diterima oleh fondasi, mendesain jumlah tiang pancang yang dibutuhkan, mendesain penulangan pada Pile Cap serta penulangan tiang pancang. Hasil perhitungan kapasiktas dukung tiang pancang mengunakan metode Meyerhof pada tanah pasir dan metode deRuiter dan Beringen pada tanah lempung didapatkan hasil sebagai berikut : untuk tiang diameter 0,3 m sebesar 534,856 kN, diameter 0,4 m sebesar 780,257 kN, diameter 0,5 m sebesar 827,689 kN. Perhitungan beban struktur atas didapatkan nilai beban aksial kolom terbesar 2293,510 kN. Jumlah tiang pancang yang dibutuhkan diameter 0,3 m jumlahnya 6 tiang, diameter 0,4 dan 0,5 m sebanyak 4 tiang.
Perencanaan Fondasi Tiang Pancang Gedung Kantor Taman Wisata Candi Yogyakarta Agus Susanto; R Renaningsih; Qunik Wiqoyah; Dhimas Adha Aji Putra
Prosiding Simposium Nasional Rekayasa Aplikasi Perancangan dan Industri 2021: Prosiding Simposium Nasional Rekayasa Aplikasi Perancangan dan Industri
Publisher : Universitas Muhammadiyah Surakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (298.344 KB)

Abstract

Proyek pembangunan Gedung Kantor Taman Wisata Candi Yogyakarta terdiri 7 lantai, 1 basement, dan 1 rooftop. Dari hasil penyelidikan tanah diketahui bahwa letak lapisan tanah keras pada kedalaman 22 meter dengan muka air tanah pada kedalaman 9 meter. Berdasarkan data tanah tersebut maka jenis fondasi yang cocok untuk gedung tersebut adalah fondasi tiang pancang. Direncanakan fondasi tiang pancang dengan diameter 0,3 m; 0,4 m; dan 0,5 m yang kemudian dipilih fondasi dengan diameter tiang yang mempunyai nilai efisiensi kelompok tiang tertinggi. Bertujuan untuk menghitung besar kapasitas dukung tiang tunggal, menghitung jumlah tiang pancang yang dibutuhkan, menghitung kapasitas dukung kelompok tiang, membuat desain penulangan pile cap, dan menghitung penurunan tiang. Kapasitas dukung tiang dianalisis dengan cara statis menggunakan prinsip kombinasi end bearing dan friction pile dengan metode Mayerhoff berdasarkan nilai N-SPT. Nilai kapasitas dukung tiang tunggal adalah sebesar 1366,455 kN pada diameter 0,3 m, 2158,124 kN pada diameter 0,4 m, dan 3083,772 kN pada diameter 0,5 m. Jumlah tiang yang dibutuhkan pada diameter 0,3 m sebanyak 15 tiang, diameter 0,4 m sebanyak 9 tiang, dan diameter 0,5 m sebanyak 8 tiang. Dipilih tiang yang mempunyai nilai efisiensi kelompok tiang tertinggi yaitu tiang dengan diameter 0,5 m dengan kapasitas dukung kelompok tiang sebesar 18354,611 kN. Dimensi pile cap 3 m x 6 m x 1,2 m dengan tulangan untuk menahan momen Mx sebesar D22-90 sedangkan untuk menahan momen My sebesar D22-70. Penurunan tiang yang terjadi sebesar 2,213 cm < penurunan ijin tiang 5 cm sehingga aman.
Kuat Geser Tanah Lanau-Lempung dengan Variasi Durasi Kontaminasi Limbah Oli Anto Budi Listawan; Qunik Wiqoyah; R Renaningsih; Agus Susanto; Ridha Febriani
Prosiding Simposium Nasional Rekayasa Aplikasi Perancangan dan Industri 2021: Prosiding Simposium Nasional Rekayasa Aplikasi Perancangan dan Industri
Publisher : Universitas Muhammadiyah Surakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (191.536 KB)

Abstract

Limbah oli merupakan salah satu limbah yang perlu diperhatikan akhir-akhir ini. Pembuangan limbah oli sembarangan dapat membahayakan lingkungan. Salah satu yang terganggu akibat limbah oli ini adalah kekuatan tanah. Untuk mengetahui pengaruh dari limbah oli terhadap kekuatan tanah, maka dilakukan penelitian yang bertujuan untuk membandingkan kekuatan tanah, yaitu kuat geser tanah dengan parameter nilai kohesi (c) dan sudut geser (Ø) pada tanah asli dengan tanah yang sudah terkontaminasi limbah oli. Dengan menggunakan sampel tanah yang berasal dari Kecamatan Gantiwarno, Klaten dan untuk limbah oli diambil dari bengkel sepeda motor yang ada di Kartasura. Variasi yang dilakukan terletak pada durasi kontaminasi limbah oli yaitu ½ minggu, 1 minggu, dan 2 minggu di dalam alat pressurize fill tank. Dilakukan pengujian sifat fisis dan mekanis tanah, untuk sifat fisis terdiri dari uji kadar air, berat jenis, berat volume, batas-batas Atterberg, gradasi butiran dan klasifikasi tanah. Untuk sifat mekanis terdiri dari uji pemadatan menggunakan standart proctor dan uji kuat geser langsung (direct shear test). Berdasarkan hasil pengujian uji kuat geser langsung, didapatkan nilai kohesi yang selalu turun berturut-turut seiring lamanya durasi kontaminasi yaitu 0.300 kg/cm², 0.254 kg/cm², 0.218 kg/cm², dan 0.195 kg/cm². Berbanding terbalik dengan sudut gesek dalam yang nilainya semakin naik seiring bertambahnya durasi kontaminasi limbah oli yaitu 25.560°, 26.710°, 27.209°, dan 29.032°. Tegangan geser pada tiap variasi juga mengalami penurunan mulai dari beban terkecil hingga beban terbesar. Hal ini menunjukkan bahwa kuat geser tanah semakin menurun seiring dengan bertambahnya durasi kontaminasi limbah oli.