Claim Missing Document
Check
Articles

Found 9 Documents
Search

EFEKTIVITAS MODEL LEARNING CYCLE 7E MENINGKATKAN AKTIVITAS BELAJAR DAN KARAKTER JUJUR DALAM PEMBELAJARAN AKUNTANSI Haryanto, Dedy; Herkulana, Herkulana; Purwaningsih, Endang
Jurnal Pendidikan dan Pembelajaran Khatulistiwa Vol 8, No 2 (2019): Februari 2019
Publisher : Jurnal Pendidikan dan Pembelajaran Khatulistiwa

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (656.418 KB)

Abstract

AbstractThis research analysed the effectivity of The Application of Learning Model ?Learning Cycle 7E? in Improving Honest Character and Learning Activity in Accounting Learning for Students of Immanuel Vocational High School Pontianak. The research was an experiment research done in 3 cycles. The population of the research was the X Accounting Class. The sample was random sampling technique for 2 classes, control class and experiment class. The technique for data collecting in the research was using test, questionnaire, observation, and documentation. The technique of data analysis used ?uji-t? to test the difference of treatment, for the experiment class was using learning cycle 7E, and control class was using conventional learning model. The data analysis was done with descriptive statistic quantitative data analysis. The research result showed that the application of learning cycle 7E could increase the learning activity and students? honesty in accounting lesson.         Keywords : Learning Cycle 7E, Learning Activity and honest Character
KARAKTERISASI PROTOTIPE HEATER ELEMENT SYSTEM PADA UNTAI UJI RCCS-RDNK MENGGUNAKAN KAMERA INFRA MERAH HARYANTO, DEDY; GIARNO, GIARNO; WITOKO, JOKO PRASETIO; KUSNUGROHO, GREGORIUS BAMBANG HERU; KUSUMASTUTI, RAHAYU; JUARSA, MULYA
ELKOMIKA: Jurnal Teknik Energi Elektrik, Teknik Telekomunikasi, & Teknik Elektronika Vol 8, No 2 (2020): ELKOMIKA: Jurnal Teknik Energi Elektrik, Teknik Telekomunikasi, & Teknik Elektro
Publisher : Institut Teknologi Nasional, Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26760/elkomika.v8i2.313

Abstract

ABSTRAKReactor Cavity Cooling System (RCCS) adalah salah satu sistem keselamatan pada Reaktor Daya Non Komersial (RDNK). Untuk mensimulasikan keadaaan tersebut, dibuat prototype Heater Element System (HES) yang merupakan sistem pemanas listrik dan berfungsi untuk memberikan kalor pada simulator dinding RPV (wall) seperti pada acuan RPV tipe HTGR. Tujuan penelitian adalah untuk memperoleh karakteristik temperatur selama pemanasan prototype HES hingga mencapai temperature 400°C berdasarkan posisi vertikal dan horizontal HES. Metode pengamatan dilakukan dengan menggunakan kamera infra merah NEC tipe TH9100ML sebagai alat ukur temperatur dan alat visualisasi ditribusi temperatur. Hasil pengamatan menunjukkan, bahwa kehilangan kalor pada prototipe HES pada posisi vertikal lebih kecil dibandingankan pada posisi horizontal hal ini disebabkan karena luas permukaan pada posisi horizontal sebesar 7,260 cm2 lebih memungkinkan untuk kehilangan kalor lebih besar. Posisi vertikal temperatur yang dicapai pada wall prototipe HES lebih tinggi dibandingkan pada posisi horizontal.Kata Kunci: RCCS, Heater Element System, kamera infra merah, temperatur ABSTRACTReactor Cavity Cooling System (RCCS) is one of the safety systems in Non-Commercial Power Reactors (RDNK). To simulate this situation, a prototype Heater Element System (HES) was made using electric heating system as a heat sources and it serves to provide radiation heat to the RPV wall simulator as the reference of the RPV of HTGR type. The purpose of this study was to obtain the temperature characteristics during the heating of the HES prototype to reach temperatures of 400°C base on HES position, horizontal and vertical positions. The observation method was carried out using a TH9100ML infrared camera NEC type as a temperature measurement and a temperature distribution base on visualization. The observations show that the heat loss in the HES prototype in the vertical position is smaller than in the horizontal position because this is because the surface area in the horizontal position 7.260 cm2 is more likely to lose more heat. The vertical position the temperature achieved on the HES prototype wall is higher than in the horizontal position.Keywords: RCCS, Heater Element System, infrared camera, temperature
Investigasi Kinerja Heat Exchanger pada Cooling Tank Section Untai FASSIP-03 NT Haryanto, Dedy
Navigation Physics : Journal of Physics Education Vol 5, No 2 (2023): Navigation Physics : Journal of Physics Education Vol. 5 No. 2 Tahun 2023
Publisher : UNIVERSITAS INDRAPRASTA PGRI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30998/npjpe.v5i2.2423

Abstract

Untai uji Fasilitas Simulasi Sistem Pasif (FASSIP) merupakan fasilitas uji eksperimen sistem pendingin pasif untuk pengambilan panas sisa hasil peluruhan yang dihasilkan oleh teras reaktor selama kondisi kecelakaan. Cooling tank Section (CTS) merupakan salah satu komponen dari fasilitas untai FASSIP 03 NT. Komponen ini dilengkapi dengan penukar kalor (heat exchanger), terdapat 3 jenis  penukar kalor yang dapat diaplikasikan pada CTS. Yaitu penukar kalor tipe Straight Pipe Heat Exchanger (SPHE), tipe Straight Pipe Fins Heat Exchanger (SPFHE) dan tipe Helical Pipe Heat Exchanger (HPHE). Penelitian ini bertujuan untuk mengetahui kinerja tiga tipe penukar kalor dengan metode perhitungan meggunakan persamaan one-dimensional steady heat conduction. Proses perhitungannya menggunakan software Matlab. Penukar kalor tipe HPHE mempunya panjang yang jauh lebih besar yaitu 5,176 m sehingga tahanan termalnya (Rth) sangat kecil yaitu sebesar 0.004171 ℃/W. Perubahan laju energi kalor pada CTS dengan penukar kalor HPHE sebesar 2397 watt. Untuk mencapai mencapai selisih temperatur air sekunder CTS (ΔT2) sebesar 5 ℃, penukar kalor tipe HPHE membutuhkan waktu 3,464 jam.
Investigation of Heat Exchanger Performance in The Heating Tank Section of Loop FASSIP 03 NT Haryanto, Dedy; Budiman, Arif Adtyas; Putra, Muhammad Ganjar; Setiawan, Putut Hery; Juarsa, Mulya
Jurnal Teknologi Vol 16, No 1 (2024): Jurnal Teknologi
Publisher : Fakultas Teknik Universitas Muhammadiyah Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24853/jurtek.16.1.41-52

Abstract

The Passive System Simulation Facility (FASSIP) loop is an experimental test facility for a passive cooling system to recover the residual heat from decay produced by the reactor core during accident conditions. The Heating Tank Section (HTS) is one of the components of the FASSIP 03 NT facility. This component is equipped with a heat exchanger, 3 types of heat exchangers can be applied to HTS. Namely heat exchangers of the Straight Pipe Heat Exchanger (SPHE) type, the Straight Pipe Fins Heat Exchanger (SPFHE) type, and the Helical Pipe Heat Exchanger (HPHE) type. A modification was made to increase the efficiency of HTS, namely replacing the electric heater on the HTS from a ceramic band heater type to an immersion heater type. With this modification, it is necessary to know the performance of the heat exchanger on HTS and its speed in reaching operational temperature. The HPHE-type heat exchanger is more efficient than the SPHE-type and SPFHE-type heat exchangers. The HPHE-type heat exchanger has a much larger length of 5.5 m, so the thermal resistance (Rth) is very small, namely 0.003926 ℃/W. To reach the working fluid temperature in the range of 50 – 90 ℃, the HPHE-type heat exchanger requires 35 – 86 minutes.
Thermal Resistance of the Loop Heat Pipe Prototype in Steady State Conditions Haryanto, Dedy; Giarno, Giarno; Hatmoko, Sumantri; Pambudi, Yoyok Dwi Setyo; Kusuma, M. Hadi
Semesta Teknika Vol 26, No 2 (2023): NOVEMBER
Publisher : Universitas Muhammadiyah Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.18196/st.v26i2.18788

Abstract

The nuclear accident at the Fukushima Daiichi nuclear power plant in March 2011 in Japan caused a tsunami and submerged the emergency diesel generator resulting in a station blackout (SBO). Based on the accident, a study was conducted on the use of passive safety systems as a support for active safety systems in nuclear reactor cooling systems. The Loop Heat Pipe (LHP) prototype is a small-scale LHP research facility, one of which is used to determine the characteristics and heat transfer events in LHP. Calculations to determine the thermal resistance of the LHP prototype need to be carried out to determine its performance level. The research was carried out experimentally for data collection followed by calculations based on the data that had been obtained. The calculation results obtained that the lowest thermal resistance is 0.014 °C/w with a 100% filling ratio and an airflow velocity of 2.5 m/s, so the setting of filling ratio and airflow velocity produces the best LHP prototype performance. The higher the airspeed, the greater the heat released by the condenser resulting in the value of the thermal resistance of the LHP prototype getting smaller. Thus, the greater the airspeed, the lower the thermal resistance of the LHP prototype, this indicates that the performance of the LHP prototype is increasing.
Karakterisasi Prototipe Heater Element System pada Untai Uji RCCS-RDNK menggunakan Kamera Infra Merah HARYANTO, DEDY; GIARNO, GIARNO; WITOKO, JOKO PRASETIO; KUSNUGROHO, GREGORIUS BAMBANG HERU; KUSUMASTUTI, RAHAYU; JUARSA, MULYA
ELKOMIKA: Jurnal Teknik Energi Elektrik, Teknik Telekomunikasi, & Teknik Elektronika Vol 8, No 2: Published May 2020
Publisher : Institut Teknologi Nasional, Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26760/elkomika.v8i2.313

Abstract

ABSTRAKReactor Cavity Cooling System (RCCS) adalah salah satu sistem keselamatan pada Reaktor Daya Non Komersial (RDNK). Untuk mensimulasikan keadaaan tersebut, dibuat prototype Heater Element System (HES) yang merupakan sistem pemanas listrik dan berfungsi untuk memberikan kalor pada simulator dinding RPV (wall) seperti pada acuan RPV tipe HTGR. Tujuan penelitian adalah untuk memperoleh karakteristik temperatur selama pemanasan prototype HES hingga mencapai temperature 400°C berdasarkan posisi vertikal dan horizontal HES. Metode pengamatan dilakukan dengan menggunakan kamera infra merah NEC tipe TH9100ML sebagai alat ukur temperatur dan alat visualisasi ditribusi temperatur. Hasil pengamatan menunjukkan, bahwa kehilangan kalor pada prototipe HES pada posisi vertikal lebih kecil dibandingankan pada posisi horizontal hal ini disebabkan karena luas permukaan pada posisi horizontal sebesar 7,260 cm2 lebih memungkinkan untuk kehilangan kalor lebih besar. Posisi vertikal temperatur yang dicapai pada wall prototipe HES lebih tinggi dibandingkan pada posisi horizontal.Kata Kunci: RCCS, Heater Element System, kamera infra merah, temperatur ABSTRACTReactor Cavity Cooling System (RCCS) is one of the safety systems in Non-Commercial Power Reactors (RDNK). To simulate this situation, a prototype Heater Element System (HES) was made using electric heating system as a heat sources and it serves to provide radiation heat to the RPV wall simulator as the reference of the RPV of HTGR type. The purpose of this study was to obtain the temperature characteristics during the heating of the HES prototype to reach temperatures of 400°C base on HES position, horizontal and vertical positions. The observation method was carried out using a TH9100ML infrared camera NEC type as a temperature measurement and a temperature distribution base on visualization. The observations show that the heat loss in the HES prototype in the vertical position is smaller than in the horizontal position because this is because the surface area in the horizontal position 7.260 cm2 is more likely to lose more heat. The vertical position the temperature achieved on the HES prototype wall is higher than in the horizontal position.Keywords: RCCS, Heater Element System, infrared camera, temperature
Pengaruh Jenis Restraint pada Kekuatan Mekanik Support Untai FASSIP 03 NT HARYANTO, DEDY; GIARNO, GIARNO; KUSNUGROHO, GREGORIUS BAMBANG HERU; ROSIDI, AINUR; PAMUNGKAS, ADHIKA ENGGAR; JUARSA, MULYA
ELKOMIKA: Jurnal Teknik Energi Elektrik, Teknik Telekomunikasi, & Teknik Elektronika Vol 10, No 2: Published April 2022
Publisher : Institut Teknologi Nasional, Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26760/elkomika.v10i2.394

Abstract

ABSTRAKKegiatan penelitian yang dilakukan dilatarbelakangi oleh kejadian kecelakaan pada PLTN Fukushima Dai-Ichi Jepang. Untai Fasilitas Simulasi Sistem Pasif-03 Nanobubbles Transparent (FASSIP 03 NT) menggunakan fluida Nanobubbles sebagai fluida kerja. Support untai FASSIP 03 NT merupakan salah satu komponen di untai FASSIP-03 NT, berfungsi sebagai penopang seluruh komponen untai FASSIP 03 NT sehingga perlu diketahui kekuatan mekaniknya meliputi tegangan mekanik dan translational displacementnya. Metode pengujian dilakukan secara simulasi menggunakan software CATIA yang merekomendasikan penggunaan restraint jenis slider pada keempat kaki support untai FASSIP 03 NT. Dengan adanya penelitian sistem pasif ini maka kondisi ketiadaan catu daya listrik bagi pompa pendingin teras reaktor PLTN tidak berakibat fatal, karena sistem pendingin pasif dapat mengambil alih fungsi pendinginan pada teras reaktor.Kata kunci: FASSIP 03 NT, tegangan mekanik, translasional displacement, restraint, clamp, slider  ABSTRACTThe research activity was carried out against the background of an accident at the Fukushima Dai-Ichi Nuclear Power Plant in Japan. Passive System Simulation Facility Strand-03 Nanobubbles Transparent (FASSIP 03 NT) uses Nanobubbles fluid as the working fluid. The FASSIP 03 NT strand support is one of the components in the FASSIP-03 NT strand, it functions as a support for all FASSIP 03 NT strand components so it is necessary to know its mechanical strength including mechanical stress and translational displacement. Methodology has been done through simulation testing using CATIA software, it is recommended to use a slider type restraint on the four legs of the FASSIP 03 NT strand support. With this passive system research, the condition of the absence of an electric power supply for the nuclear power plant reactor core cooling pump is not fatal, because the passive cooling system can take over the cooling function in the reactor core.Keywords: FASSIP 03 NT, mechanical stress, translational displacement, restraint, clamp, slider
KARAKTERISASI LAJU ALIRAN MASSA PADA PIPA BAGIAN HEATER BERDASARKAN PERUBAHAN DAYA DI UNTAI (FASSIP-01) MOD.1 Fauzi, Ahmad; Juarsa, Mulya; Giarno, Giarno; Heru, Gregorius Bambang; Haryanto, Dedy; Irianto, Ignatius Djoko
AME (Aplikasi Mekanika dan Energi): Jurnal Ilmiah Teknik Mesin Vol. 5 No. 1 (2019)
Publisher : Universitas Ibn Khaldun Bogor

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (695.455 KB) | DOI: 10.32832/ame.v5i1.2331

Abstract

Kecelakaan reaktor nuklir di Fukushima Daiichi Jepang pada 11 Maret 2011, menyebabkan dilakukannya penelitian ini di berbagai negara termasuk Indonesia yang sedang mengembangkan sistem  keselamatan pasif dengan alat Untai FASSIP-01 Mod.1 di PTKRN-BATAN Serpong. Ada beberapa komponen pada Untai FASSIP-01 Mod.1 yaitu komponen pemanas yang dinamakan Blanket Ceramic Heater (BCH-02), komponen pendingin dengan sistem refrigerant cooling  system (RCS), dan tabung  ekspansi. Sistem pasif menerapkan hukum alami untuk mengamati kondisi yang tidak stabil pada  reaktor. Perlu dilakukannya eksperimen untuk mengetahui karakterisasi distribusi temperatur pada pemanas BCH-02 di Untai FASSIP-01 Mod.1 dengan memvariasikan daya dan tegangan 20 volt – 160 volt. Pengujian dilakukan selama 120 menit dan tegangan dinaikkan sebesar 20 volt selama 15 menit,  eksperimen pada BCH-02 dilakukan dengan posisi vertikal dan horizontal. Hasil eksperimen  pada BCH-02, semakin besar daya yang diberikan maka temperaturnya semakin tinggi. Temperatur yang berada di permukaan ceramic-brick lebih tinggi dibandingkan dengan temperatur di dalam pipa section, hal ini disebabkan karena terjadi heat loss pada celah celah ruang di dalam BCH-02 sebelum mencapai pipa section.
EFISIENSI HEATING TANK SECTION PADA KONDISI TUNAK BERDASARKAN VARIASI DAYA PEMANAS Haryanto, Dedy; Rosidi, Ainur; Setiawan, Putut Hery; Juarsa, Mulya
Semnas Ristek (Seminar Nasional Riset dan Inovasi Teknologi) Vol 7, No 1 (2023): SEMNAS RISTEK 2023
Publisher : Universitas Indraprasta PGRI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30998/semnasristek.v7i1.6239

Abstract

Kejadian station blackout (SBO) pada PLTN Fukushima Daiichi pada Maret 2011 di Jepang menjadi latar belakang yang penting untuk kegiatan penelitian tentang sistem pendinginan pasif pada teknologi keselamatan reaktor nuklir. Pengaruh perubahan densitas fluida di daerah panas menimbulkan gaya apung (buoyancy force) dan pengaruh perubahan densitas fluida pada keadaan dingin menimbulkan gaya gravitasi (gravitational force) sehingga terjadi sirkulasi alam pada fluida kerja (air) di sepanjang untai. Tujuan penelitian dilakukan untuk mengetahui unjuk kerja Heating Tank Section (HTS) yang dilengkapinya dengan keterbaruan berupa helical heat exchanger. Penelitian dilakukan secara eksperimental berdasarkan variasi setting temperatur air dalam tangki pemanas dan daya listrik di heater (variasi tegangan regulator). Berdasarkan hasil perhitungan efisiensi pada HTS (εH) dengan keterbaruan yang dimilikinya memiliki rentang 45,48% - 99,41% dengan efisiensi ratarata 82,58%. Efisiensi yang cukup tinggi pada HTS ini menunjukkan bahwa adanya keterbaruan penukar kalor helical meningkatkan unjuk kerja pemanasan HTS pada fasilitas Untai FASSIP-03 NT.