Electrosurgery Unit Monopolar (Cutting and Coagulation) Ridho Armi Nabawi; Dhany Alvianto Wibaksono; Tri Bowo Indrato; Triana Rahmawati
Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 1 No 1 (2019): July
Publisher : Department of Electromedical Engineering, POLTEKKES KEMENKES SURABAYA and IKATEMI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jeeemi.v1i1.7

Abstract

Electrosurgery Unit is a medical device that utilizes high frequency and voltage used to cut and dry tissue during the surgical process. The purpose of making this tool is to damage certain body tissues by heating the tissue. Heat is obtained by concentrating high frequency electricity on certain body tissues using active and passive electrodes as a medium. The Electrosurgery Unit involves the use of the CMOS 4069 IC as a frequency generator. The output frequency is set at 300 KHz then forwarded to the pulse regulating circuit and controlled with ic atmega328 then forwarded to the inverter circuit which functions to increase the voltage and output in the form of power. The module is calibrated using ESU Analyzer. This module is equipped with LOW, MEDIUM, HIGH. After the measurements are made, the more load is given higher to the tool, the higher the power released by the tool in each power selection. Then the load relationship and the power released are directly proportional. This ESU was made so that during the surgical process the body's tissue does not experience a lot of blood loss. Besides being able to use it for surgery, it can also be used to close the tissue after surgery.
A Two-Mode Digital Pressure Meter Equipped With An Automatic Leak Test Using MPX5050gp And MPXv4115vc6u Sensors Fita Florensa Rooswita; Triana Rahmawati; Syaifudin Syaifudin
Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 2 No 2 (2020): July
Publisher : Department of Electromedical Engineering, POLTEKKES KEMENKES SURABAYA and IKATEMI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jeeemi.v2i2.7

Abstract

The calibration process aims to guarantee that a measurement device is to follow the established standards. The purpose of this study is to design an automatic leak test for digital pressure meter in which the function of this device is to measure pressure on the sphygmomanometer and suction pump or other devices that use pressure parameters for measurement. This study used the Arduino as a control system, and to process the analog data into digital. Signal conditioning, based on the amplifier circuit, was also applied for the MPX5050GP and MPXV4115VC6U sensor. The proposed design used a 4x20 liquid crystal display to show the parameters in this design ware also equipped with a selector of mmHg or kPa units. The result shows that the fluctuating resolution is 0.25 mmHg. In this design, an automatic leak feature was also equipped for the sphygmomanometer. The results obtained an average error of 7.3 mmHg for sphygmomanometers. On the other hand, the suction pumps have an accuracy of less than 1.5 kPa. From these results, it was concluded that this design could be used for the measurement of devices that use positive pressure and negative pressure
Comparison of Air Pressure Control Between Discrete and PID Control Applied in the Calibration Process in Blood Pressure Meter Harisha Avin Nurcahyana; Tri Bowo Indrato; Triana Rahmawati; Wahyu Caesarendra
Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 4 No 2 (2022): April
Publisher : Department of Electromedical Engineering, POLTEKKES KEMENKES SURABAYA and IKATEMI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jeeemi.v4i2.6

Abstract

In performing the calibration of the sphygmomanometer, the officer needs to first reset the installation and pump the bulb slowly until it reaches the set point in accordance with the calibration settings where this does not provide convenience to the calibration officer. So the author wants to do research on making additional devices to support DPM calibration instruments that have been commercialized to speed up the pump process in Sphygmomanometer calibration. The purpose of this research is to make an Automatic Pump module with PID control to analyze the stability of the pressure achievement in accordance with the set point when using the smoothing program or not. This study used set points of 50, 100, 150, 200, and 250 mmHg. Data retrieval was carried out within 260 seconds at each set point at the Campus of the Department of Electrical Engineering Poltekkes Kemenkes Surabaya. The results of this study indicate that the tool testing using the smoothing program experienced small oscillations compared to the program without smoothing. The data obtained are at setting 50 the average overshoot is 54 and the average undershoot is 49; at setting 100 the average overshoot is 109 and the average undershoot is 99; at setting 150 the average overshoot is 156 and the average undershoot is 149; at setting 200 the average overshoot is 206 and the average undershoot is 196; at setting 250 the average overshoot is 253 and the average undershoot is 247. The importance of this device was made in order to make it easier and faster for the calibration officer to calibrate the Sphygmomanometer.
Accuracy Analysis on Dual Pressure (Positive and Negative) Calibrator Design to Investigate the Sensor Response Abdi Wibowo; Triana Rahmawati; Priyambada Cahya Nugraha; I Dewa Gede Hari Wisana; Honey Honey; Mansour Asghari
Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 4 No 3 (2022): July
Publisher : Department of Electromedical Engineering, POLTEKKES KEMENKES SURABAYA and IKATEMI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jeeemi.v4i3.247

Abstract

Calibration is an activity to determine the conventional correctness of the value of measuring instrument designation and measuring material by comparing against the measuring standards that are traced to national or international standards. A sphygmomanometer is a device used to measure blood pressure. Suction pump is a tool to suck various types of fluid formed from the body's secretion process that under certain conditions need to be cleaned. DPM (Digital Pressure Meter) is a tool for calibrating sphygmomanometers and suction pumps. Therefore, it takes a calibrator device to calibrate both tools. The purpose of this study was to determine the sensor response and analyze the accuracy of the design of a dual pressure calibrator (+ and -) that can be used for two devices at once (sphygmomanometer and suction pump) using one sensor (pss-C01V-R18 autonics). The research was conducted at the Campus of the Department of Electrical Engineering Of The Ministry of Health Surabaya, first the data was taken from three different brands of sphygmomanometer and suction pump, the second data was taken using module calibrators, and the third data collection from modules and comparison tools (DPM). In this study successfully measured positive and negative pressure with autonics sensors, the results obtained are accurate in accordance with the results of standard tools. The result of this tool can be used for dual pressure calibrators using autonics sensors.
The Performance Analysis of the Infrared Photodiode Sensor to Infusion Set on Infusion Device Analyzer Machine Anisa Rahma Astuti; Syaifudin; Triana Rahmawati; Khongdet Phasinam
Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 5 No 1 (2023): January
Publisher : Department of Electromedical Engineering, POLTEKKES KEMENKES SURABAYA and IKATEMI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jeeemi.v5i1.274

Abstract

Infusion pumps and syringe pumps are devices used to administer liquid medicines to patients. The frequency of using the infusion pump and syringe pump in the long term will affect the accuracy of the tool. Accuracy is very important in dosing to patients in critical conditions who require intensive care to prevent fluid balance in the body. Therefore, periodic calibration of medical devices is required at least once a year. Calibration according to Permenkes No. 54 of 2015 is a calibration activity to determine the correctness of a tool. The purpose of this research is to make an Infusion Device Analyzer (IDA) with a TFT LCD displaying a graph of flowrate parameters. The method used is to analyze the flowrate value using an infrared photodiode sensor and can see the stability of the flowrate graph on a 7-inch TFT LCD from the use of 2 brands of syringes and an infusion set. The results obtained can be stored on the SD Card. The measurement results show that the error in the performance of the syringe and infusion pump read by the module on Channel 1 with the Terumo syringe is 0.15 (10 ml/h), 0.1 (50ml/h) and 0.03 (100ml/h). . On Channel 2 it is 0.02(10ml/hour), 0.03 (50ml/hour) and 0.04(100ml/hour). When using the B-Braun Channel 1 syringe, 0.25 (10ml/h), 009(50ml/h) and 0.08(100ml/h) are used. And on Channel 2 it is 0.62 (10ml/h), 0.15 (50ml/h), and 7.3 (100ml/h). When using the Terumo Channel 1 brand infusion set at 0.05 (10ml/h), 0.3(50ml/h), and 0.04(100ml/h). On Channel 2 it is 0.14(10ml/hour), 0.02 (50ml/hour) and 0.18 (100 ml/hour). When using the B-Braun Channel 1 Infusion Set, it is 0.07(10ml/h), 0.02(50 ml/h), and 0.03 (100ml/h). Then on Channel 2 0.07 (10ml/hour), 0.02(50 ml/hour), and 0.1(100ml/hour). The conclusion of this study is that the use of 2 different infusion sets greatly affects the readings, other than that other factors can also affect the readings including the position of the hose and the placement of sensors on each channel. From the manufacture of this tool, it is expected that users can be more efficient in using a 2-channel Infusion Device analyzer which can be run at the same time.