ANALISA PENANGGULANGAN THD DENGAN FILTER PASIF PADA SISTEM KELISTRIKAN DI RSUP SANGLAH I Nengah Suweden; I Wayan Rinas
Jurnal Teknologi Elektro Vol 8 No 2 (2009): (July - December) Majalah Ilmiah Teknologi Elektro
Publisher : Universitas Udayana

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (233.367 KB)

Abstract

Sistem kelistrikan RSUP Sanglah terdiri dari lima buah MDP (Main Distribution Panel) yang melayani begitu banyak beban yang menuntut kualitas tegangan dan arus yang baik demi kelancaran pelayanan kesehatan. Dari hasil simulasi THD (Total Harmonic Distortion) pada beban listrik di RSUP Sanglah dengan simulink MATLAB 7.04, untuk THDv sudah sesuai standar sedangkan untuk THDi pada beberapa MDP tidak sesuai dengan standar yang diperbolehkan yaitu IEEE standard 519 – 1992. Dengan hasil THDi bervariasi antara 4,68% – 17,84% dan THDv bervariasi antara 0,46% - 3,77%. Dengan pengoperaian filter pasif, THD arus mengalami penurunan. Sehingga THD arus dan THD tegangan memenuhi standar IEEE 152-1992. THD arus setelah pemakaian filter memiliki nilai terendah pada 2,36 % hingga nilai tertinggi pada 2,97%. Setelah penambahan filter pasif, maka daya distorsi sistem kelistrikan di RSUP Sanglah menurun dari 40.484,068 VA menjadi 15.437,219 VA. Sehingga daya distorsi mengalami penurunan dengan total penurunan untuk keseluruhan feeder adalah 25.046,85 VA.
Sistem Kontrol Pergerakan pada Robot Line Follower Berbasis Hybrid PID-Fuzzy Logic I Putu Adinata Mas Pratama; I Nengah Suweden; I.B Alit Swamardika
PROSIDING CSGTEIS 2013 CSGTEIS 2013
Publisher : PROSIDING CSGTEIS 2013

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Abstrak—Pada umumnya sistem kendali robot line follower menggunakan kontroler konvensional atau yang biasa disebut dengan kontroler PID (Proposional Integral Derivativ). Hasil output dari penggunaan sistem kontrol jenis ini kadangkala dapat membuat pergerakan robot semakin tidak stabil jika diberikan nilai acuan (konstanta) yang sensitiv. Itu disebabkan karena semakin sensitiv nilai acuan yang diberikan, maka respon dari robot jika ada gangguan (Disturbance), dapat menyebabkan nilai overshoot dan undershoot yang tinggi. Jika dibuat nilai acuan yang kurang sensitiv, dapat mengurangi nilai overshoot dan undershoot, namun itu akan memperpanjang recovery time.Agar dapat mengatasi permasalahan ini, diterapkan metode gabungan (Hybrid) dari kontroler PID dengan Logika kabur (Fuzzy Logic). Fuzzy logic disini berfungsi untuk membantu menentukan parameter nilai error dan perubahan nilai error sebelumnya (Derror) serta memperkecil recovery time. Dari gabungan metode ini didapatkan hasil yaitu pergerakan robot semakin stabil dengan recovery time yang kecil.Keywords—PID; Robot Line Follower; Fuzzy Logic; Sistem; Kontrol
OPTIMASI MASSA KATUP LIMBAH POMPA HYDRAM TERPASANG DI WILAYAH MUNDUK GUNUNG DESA PETANG M. Suarda; N.M. Suaniti; M. Sucipta; N. Suweden; I.G.K. Dwijana
Buletin Udayana Mengabdi Vol 23 No 1 (2024): Buletin Udayana Mengabdi
Publisher : Lembaga Penelitian dan Pengabdian kepada Masyarakat

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24843/BUM.2024.v23.i01.p14

Abstract

This paper investigated the effect of the mass of the waste valve of hydraulic ram pump which has been designed and installed to deliver the clean water to the community house in the Munduk Gunung area, Petang Village. Public facilities are still minimal. One of them is the unavailability of clean water service facilities for the community, where people still rely on rainwater or buy water tanks. In accordance with the name of the area, this residential area is located in the highlands (512 m.swl), while the available water sources are in the lowlands (410 m.swl) with an elevation difference of 102 meters. The distance from the spring to the reservoir is 600 meters through a steep cliff. Initial survey results show that the spring has a flow capacity of about 3 liters/second and a potential head of 4.5 meters. The hydraulic ram pump has been designed, built, installed and operated with funding supported through the PNBP service grant from Udayana University, the PUMA scheme. The hydraulic ram pump performance test has been carried out on five variations of the waste valve mass. Performance testing shows that this hydraulic ram pump reaches its optimal performance at a mass of 3.25 kg of waste valve. Under these optimal conditions, this hydraulic ram pump operates at a total efficiency of 95% with a pumping flow of 0.115 lt/sec or 9.94 m3/day) at a pumping elevation of 102 meters, with an economic value of up to Rp. 17,885,000 per month. Therefore, it is with an investment cost of around Rp. 42,500,000 and requires almost no operational costs because it does not require fuel or electrical energy, consequently this hydram pump is very profitable to apply. Keywords: Hydraulic ram pump, waste valve mass, pump performance, Munduk Gunung area, Petang village.
UJI PERFORMANSI POMPA HYDRAM DALAM PENYEDIAAN AIR BERSIH KELOMPOK USAHA BON BELOK KOPI DAN BANJAR ADAT BON DESA BELOK/SIDAN M. Suarda; N.M. Suaniti; M. Sucipta; N. Suweden; I.G.K. Dwijana; I.P. Widiarta
Buletin Udayana Mengabdi Vol 23 No 1 (2024): Buletin Udayana Mengabdi
Publisher : Lembaga Penelitian dan Pengabdian kepada Masyarakat

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24843/BUM.2024.v23.i01.p06

Abstract

This paper examined the performance of the hydraulic ram pump that has been designed and installed to meet the clean water needs of the 'Bon Belok Kopi' Business Group and several families of Bon traditional community in Belok/Sidan Village, Petang District, Badung Regency, Bali Province. This business group is shortage to clean water in the process of processing their coffee production so that the community relies on rainwater and buys water from tank cars at a price of sixty thousand rupiah per cubic meter. Likewise, the Bon traditional community experienced the same problem, especially for their traditional activities. This problem has an impact on the capacity, quality and cost of coffee production of the business group, as well as the cleanliness, health and economy of the Bon traditional community. In the Bon area, there is a spring in the garden area belonging to the head of the business group with a flow rate of 3 liters/second at an elevation of 1024 m.swl, while residential areas are located at an elevation of 1135 m.swl. The hydraulic ram pump has been designed, built, installed and operated. The hydraulic ram pump performance test has been carried out on five variations of the pumping head. At a pumping head of 70 m, at the location of coffee processing, it produces a pumping flow of 8.84 m3/day with the pump efficiency of 71%. Meanwhile, at the highest pumping head of 110 m, at Puncak Bon Temple, it produces a pumping discharge of 5.04 m3/day with the pump efficiency of 59%. Keywords: Hydram pump, pump performance, Bon Belok Kopi, Bon traditional community.
STUDI ANALISIS GOVERNOR SEBAGAI LOAD FREQUENCY CONTROL PADA PLTG MENGGUNAKAN FUZZY LOGIC CONTROLLER Gusti Made Ngurah Christy Aryanata; I Nengah Suweden; I Made Mataram
Jurnal Teknologi Elektro Vol 17 No 1 (2018): (Januari - April) Majalah Ilmiah Teknologi Elektro
Publisher : Program Studi Magister Teknik Elektro Universitas Udayana

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24843/MITE.2018.v17i01.P15

Abstract

Sistem tenaga listrik yang baik merupakan suatu sistem yang dapat melayani beban secara berkelanjutan serta tegangan dan frekuensinya stabil. Perubahan frekuensi terjadi disebabkan oleh permintaan beban yang berubah-ubah dari waktu ke waktu. Pengaturan frekuensi pada sistem pambangkit PLTG tergantung pada pengisisan daya aktif dalam sistem. Pengaturan daya aktif ini dilakukan dengan mengatur besarnya kopel penggerak generator. Pengaturan frekuensi dilakukan dengan menambah dan mengurangi jumlah energi primer (bahan bakar) dan dilakukan pada governor. Simulasi dalam studi analisis governor sebagai load frequency control pada PLTG menggunakan fuzzy logic controller dilakukan dengan memberikan empat jenis pembebaban yaitu sebesar 0,1 pu, 0,2pu, 0,3 pu dan 0,4 pu. Simulasi dilakukan untuk membandingkan output respon frekuensi dinamik dan waktu kestabilan yang dihasilkan menggunakan fuzzy logic controller dengan PI controller. Berdasarkan hasil analisis perbandingan yang dilakukan membuktikan bahwa governor sebagai load frequency control menggunakan fuzzy logic control lebih baik dibandingkan dengan menggunakan PI kontroller. Hal ini dapat dilihat dari output respon frekuensi dan waktu kestabilannya.
Analisis Stabilitas Sistem Tenaga Listrik Dengan Automatic Generation Control (AGC) Dua Area Menggunakan Fuzzy Logic Controller Made Dwi Noviantara; I Nengah Suweden; I Made Mataram
Jurnal Teknologi Elektro Vol 17 No 2 (2018): (May - Agustus) Majalah Ilmiah Teknologi Elektro
Publisher : Program Studi Magister Teknik Elektro Universitas Udayana

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24843/MITE.2018.v17i02.P15

Abstract

The power system must be able to server the load in a sustainable manner with good service quality, such as constant voltage and frequency, quickly stabilized when load changes occur. The control generator automatically changes the frequency to the highest value when the system changes every time. This is called AGC. To keep the frequency in a stable state required frequency control system. Currently developing a lot of control system with fuzzy logic method. The simulation is performed using 5 membership functions and gives a loading of 0.1 pu, using MATLAB-Simulink software. From the analysis result, the comparison of output of frequency response in overshoot condition with conventional method yielded , settling time of 20.5 second. While the fuzzy logic controller method produces frequency response output in the overshoot state that is , settling time is 12 seconds. Whit the fuzzy logic controller method produces better performance and faster than conventional methods.
ANALISA PENANGGULANGAN THD DENGAN FILTER PASIF PADA SISTEM KELISTRIKAN DI RSUP SANGLAH I Nengah Suweden; I Wayan Rinas
Jurnal Teknologi Elektro Vol 8 No 2 (2009): (July - December) Majalah Ilmiah Teknologi Elektro
Publisher : Program Studi Magister Teknik Elektro Universitas Udayana

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Sistem kelistrikan RSUP Sanglah terdiri dari lima buah MDP (Main Distribution Panel) yang melayani begitu banyak beban yang menuntut kualitas tegangan dan arus yang baik demi kelancaran pelayanan kesehatan. Dari hasil simulasi THD (Total Harmonic Distortion) pada beban listrik di RSUP Sanglah dengan simulink MATLAB 7.04, untuk THDv sudah sesuai standar sedangkan untuk THDi pada beberapa MDP tidak sesuai dengan standar yang diperbolehkan yaitu IEEE standard 519 – 1992. Dengan hasil THDi bervariasi antara 4,68% – 17,84% dan THDv bervariasi antara 0,46% - 3,77%. Dengan pengoperaian filter pasif, THD arus mengalami penurunan. Sehingga THD arus dan THD tegangan memenuhi standar IEEE 152-1992. THD arus setelah pemakaian filter memiliki nilai terendah pada 2,36 % hingga nilai tertinggi pada 2,97%. Setelah penambahan filter pasif, maka daya distorsi sistem kelistrikan di RSUP Sanglah menurun dari 40.484,068 VA menjadi 15.437,219 VA. Sehingga daya distorsi mengalami penurunan dengan total penurunan untuk keseluruhan feeder adalah 25.046,85 VA.