Claim Missing Document
Check
Articles

Found 4 Documents
Search

SIMULATION OF OPERATIONAL CONDITIONS OF FASSIP-02 NATURAL CIRCULATION COOLING SYSTEM EXPERIMENTAL LOOP Dr.Anhar Riza Antariksawan; Surip Widodo; Mulya Juarsa; Dedy Haryanto; Mukhsinun Hadi Kusuma; Nandy Putra
Jurnal Sains dan Teknologi Nuklir Indonesia (Indonesian Journal of Nuclear Science and Technology) Vol 19, No 1 (2018): Februari 2018
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (490.664 KB) | DOI: 10.17146/jstni.2018.19.1.4036

Abstract

The natural circulation is considered in the design of emergency passive core cooling system in a nuclear power plant. In that context, in order to investigate the characteristics of the natural circulation, FASSIP-02 experimental loop is designed. This paper simulates the various operational conditions with different condition of the heater power, the pipe insulation and the expansion tank's valve using RELAP5 code. The objective is to obtain the best operational conditions of FASSIP-02 once it is built. The simulation results show that the until 50,000 s the steady state condition could not be achieved yet when the heater power greater than 10 kW. The pipe insulation reduced the heat loss to the environment and in turn it causes faster increase of the water temperature inside the pipe. While, if the expansion tank's valve is closed during the operation, the pressure inside the loop would increase, faster when the heater power is higher. It is concluded that in all cases to avoid the saturation condition, the heater power should be maintained lower than 10 kW, especially when the loop pipe is insulated.
Pengukuran Fluks Kalor Prosessor dengan Metode Simulasi Fluks Kalor Plat Datar Wayan Nata Septiadi; Nandy Putra; Engkos K; Raldi Artono Koestoer
Jurnal Energi Dan Manufaktur Vol 7 No 2 (2014): Oktober 2014
Publisher : Department of Mechanical Engineering, University of Udayana

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (475.457 KB)

Abstract

Metode pengukuran dalam suatu penelitian di bidang perpindahan kalor khususnya pipakalor merupakan suatu hal yang sangat penting untuk bisa mendapatkan suatu data yangmemang akurat. Penelitian ini adalah untuk mendapatkan kondisi temperatur dan flukskalor pada permukaan plat pemanas yang mampu mewakili kondisi temperature dan flukskalor pada permukaan prosessor atau CPU. Penelitian ini meliputi tahap uji quasi steadystate, kalibrasi termokopel, pengukuran temperature permukaan CPU, karakterisasi platpemanan dan karakterisasi palt simulator. Dalam hal ini parameter yang dijadikan acuanpada plat simulator adalah temperature permukaan prosessor.Kata kunci: Pengukuran, Fluks kalor, ProsessorMeasurement methods in a research of the heat transfer especially the heat pipe is veryimportant to be able to get a really accurate data. This research is to obtain the conditions oftemperature and heat flux on the surface of the heating plate that capable of representingthe conditions of temperature and heat flux on the surface of the processor or CPU. Thisresearch includes the quasi steady state test phase, thermocouple calibration, CPU surfacetemperature measurement, characterization and characterization of heater plate andsimulator plate. In this case the parameters are used as reference in the simulator plate isthe surface temperature of processor..Keywords: Measurement, heat flux, processor
Aplikasi PCM Bees Wax sebagai teknologi penyimpan energi (thermal energy storage) pada pemanas air domestik Adi Winarta; Muhammad Amin; Nandy Putra
Jurnal Energi Dan Manufaktur Vol 8 No 2 (2015): Oktober 2015
Publisher : Department of Mechanical Engineering, University of Udayana

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (333.43 KB)

Abstract

Abstrak:Sistem pemanas air merupakan salah satu pengguna energi terbesar pada industri perhotelan selain pengkondisian udara dan penerangan. Temperatur air yang dihasilkan pada sistem pemanas air domestik biasanya berkisar antara 55-65°C. Phase Change Material (PCM) sebagai salah satu teknologi thermal storage dapat dimanfaatkan untuk meningkatkan efisiensi penggunaan energi listrik pada sistem pemanas air. PCM memanfaatkan kalor laten untuk menyimpan energi dan melepaskannya pada kondisi yang diinginkan. Pada penelitian ini diuji sebuah sistem pemanas air domestik dengan volume air sebesar 100 liter. Sumber kalor pada pemanas ini menggunakan heater listrik dengan daya total 3000 Watt. Sejumlah PCM diletakkan didalam drum pemanas air sebagai thermal storage dengan tujuan mempertahankan temperatur air pada suhu 60C sehingga penggunaan listrik oleh heater dapat dikurangi. Material PCM menggunakan bahan organik lilin lebah atau bees wax yang memiliki titik leleh 52°C-66°C. Bees wax ditempatkan pada kontainer yang terbuat dari pipa tembaga dengan diameter dalam 38,1 milimeter dan panjang 260 mm. Pengujian dilakukan dengan menguji tiga variasi massa PCM yakni 1,9 kg, 5,1 kg, dan 7,3 kg. Hasil pengujian menyatakan bahwa penggunaan PCM 1,9 kg memiliki waktu penundaan heater yang paling lama yakni 1 jam 6 menit 40 detik. Penggunaan PCM masih memiliki penggunaan daya yang lebih besar dibandingkan tanpa PCM yakni 12,93 kJ pada masa PCM 1,9 kg, 13,88 kJ pada 5,1 kg PCM dan 14,803 kJ pada 7,3 kg masa PCM. Kata kunci: Phase Change Material (PCM), Beewax, Domestic Water Heater.Abstract:Water heating system is one of the largest energy users in the hospitality industry, in addition to the air conditioning and lighting. The temperature of water which is produced on the domestic water heating systems typically range between 55-65°C. Phase Change Material (PCM) as one of the thermal storage technology can be utilized to improve the efficiency of energy use in water heating systems. PCM utilizes latent heat to store energy and release it at the desired conditions.This study tested a domestic water heating system with 100 liters water volume. The heat source in heating is using an electric heater with a total power of 3000 Watts. A number of PCM is placed inside the water heater drum as a thermal storage to maintaining the temperature of the water keep at 60°C, so that the use of electricity by the heater can be reduced. PCM material using organic materials such as bees wax which has a melting point of 52°C - 66°C. Bees wax is placed in containers made of copper pipe with an inner diameter of 38.1 millimeters and a length of 260 mm. Testing is done by testing five variations of the PCM mass 1,9 kg, 5,1 kg, and 7,3 kg. The test results stated, with the latent heat 0,242 kJ/g bees wax is capable to maintaining the temperature of water at 65°C for 116.6 minutes. Keywords: Phase Change Material (PCM), Bees Wax, Pemanas air domestic Keywords : Phase Change Material (PCM), Bees Wax, Pemanas air domestic
Karakterisasi Konduktivitas Termal Nanofluida Oksida Berbasis Fluida Dasar H2O Wayan Nata Septiadi; Nandy Putra; Rosari Saleh
Jurnal Energi Dan Manufaktur Vol 8 No 2 (2015): Oktober 2015
Publisher : Department of Mechanical Engineering, University of Udayana

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (404.621 KB)

Abstract

Abstrak:Sejak nanofluida mulai diperkenalkan untuk peningkatan konduktivitas termal, hal ini memberikan suatu harapan yang besar bagi bidang perpindahan kalor. Penelitian dan pengaplikasian nanofluida terus mengalami perkembangan dan peningkatan. Pendispersian partikel nano ke dalam fluida dasar sehingga membentuk suatu suspense nanofluida tentunya memiliki karakteristik konduktivitas termal yang berbeda beda antara penggunaan nano partikel satu dengan nano partikel lainnya. Penggunaan nano partikel oksida juga mulai banyak digunakan sebagai fluida kerja alternative baik sebagai fluida kerja alat penukar kalor maupun sebagai fluida kerja pada pipa kalor dan teknologi pendingin lainnya. Hal ini menjadi sangat penting untuk mengetahui karakteristik konduktivitas termal nanofluida oksida pada fraksi volume rendah dan fraksi volume tinggi. Penelitian dilakukan dengan mendispersikan partikel nano CuO, Al2O3 dan TiO2 yang masing masing berukuran 20 nm ke dalam fluida dasar air (H2O) dan dilakukan sonifikasi menggunakan ultrasonic prosessor selama 30 menit. Fraksi volume dibuat dalam fraksi volume rendah yakni 0.1% sampai dengan 0.9% dan fraksi volume tinggi 1% sampai dengan 10%. Pengujian konduktivitas termal nanofluida oksida pada fraksi volume rendah dan fraksi volume tinggi dilakukan dengan menggunakan metode KD2 yang diukur pada temperatur 25oC. Hasil pengujian menunjukkan karakterisasi konduktivitas termal nanofluida oksida yang dalam hal ini adalah CuO-Air, Al2O3-Air dan TiO2-Air masing-masing memberikan peningkatan konduktivitas termal yang signifikan pda fraksi volume rendah. Konduktivitas termal CuO-Air baik pada fraksi volume rendah maupun pada fraksi volume tinggi lebih tinggi dibandingkan dengan konduktivitas termal Al2O3-Air dan TiO2-Air. Kata kunci: Konduktivitas termal, nanofluida, oksida, fraksi volume.Abstract:Since nanofluids was introduced to increase the thermal conductivity, it gives great hope for the field of heat transfer. Research and application of nanofluids continues to experience growth and improvement. Dispersing nanoparticles into the base fluid to form a suspense nanofluids certainly has the different characteristics of a thermal conductivity. The use of nano-oxide particles are also widely used as a good alternative working fluid as the working fluid heat exchanger as well as the working fluid in the heat pipes and other cooling technologies. Its very important to know the characteristics of the thermal conductivity of nanofluids oxide at low and high volume fraction. The study was conducted by dispersing nanoscale particles of CuO, Al2O3 and TiO2 are each measuring 20 nm in a base fluid water (H2O) and doing sonification using ultrasonic processor for 30 minutes. Fraction volume created in volume fraction lower at 0.1% to 0.9% and a high volume fraction of 1% to 10%. Thermal conductivity of nanofluids testing oxides at low volume fraction and a high volume fraction KD2 done using a method that is measured at a temperature of 25oC. The test results show the characterization of thermal conductivity of nanofluids oxide in this case is CuO- Water, Al2O3-Water and TiO2-Water each provide a significant increase in thermal conductivity at low volume fraction. The thermal conductivity of CuO-water nanofluid higher at low and high volume fraction than the thermal conductivity of Al2O3-Water and TiO2-Water. Keywords: Thermal conductivity, nanofluids, oxide, volume fraction.