Claim Missing Document
Check
Articles

Found 5 Documents
Search
Journal : Jurnal Teknik

Analisis Karakteristik Saluran Komunikasi Satelit Bergerak Berdasarkan Rasio S/N Daerah Makassar Kondisi Clear Sky Hidayat, Muhammad Reza; Arif, Munawwar; Hasanuddin, Zulfajri Basri; Palantei, Elyas
Jurnal Teknik: Media Pengembangan Ilmu dan Aplikasi Teknik Vol 17 No 1 (2018): Jurnal Teknik - Media Pengembangan Ilmu dan Aplikasi Teknik
Publisher : Fakultas Teknik - Universitas Jenderal Achmad Yani

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1347.447 KB) | DOI: 10.26874/jt.vol17no1.60

Abstract

Pada penelitian ini dilakukan pengukuran dan analisis signal strength GPS dengan menguji software berbasis PC dengan sistem operasi Linux. Menggunakan beberapa sofware untuk pengambilan data, pengolahan dan pengujian GPS receiver yang memiliki kemampuan menentukan posisi user pada kondisi mobile (bergerak) dengan tampilan visual pada MAP (peta). Penelitian dilakukan pada beberapa lokasi yang memiliki topografi yang diinginkan. Software-software berbasis PC yang digunakan pada Sitem Operasi Linux (Ubuntu v 10.10) yaitu GPSd (GPS Daemon), GPSpipe, XGPS, dan Tango GPS untuk Map (Peta) sedangkan untuk software berbasis PC pada Windows yaitu Matlab v 7.6. Software-software tersebut sudah mempunyai kemampuan menampilkan posisi satelit dan user beserta informasi yang sangat penting tanpa harus menerima data mentah lagi pada NMEA 0183 dalam kondisi mobile. Pengamatan dilakukan dengan mengumpulkan nilai S/N dari masing-masing satelit yang tertangkap oleh penerima di daerah kota Makassar.Penelitian ini terfokus pada tiga titik 3 (tiga) kondisi yakni LOS (line of sight), NLOS Moderate dan NLOS Heavy. Data yang diinput dari NMEA GPS pipe untuk 12 PRN disortir dan output yang dihasilkan dalam bentuk grafik kualitas signal strength setiap PRN satelit, untuk tampilan visual pada XGPS.
Purwarupa Mode Konverter Rectangular Waveguide Menggunakan Double-Trench M. Reza Hidayat; Adhitya Ari Poetra
Jurnal Teknik: Media Pengembangan Ilmu dan Aplikasi Teknik Vol 19 No 1 (2020): Jurnal Teknik - Media Pengembangan Ilmu dan Aplikasi Teknik
Publisher : Fakultas Teknik - Universitas Jenderal Achmad Yani

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26874/jt.vol19no01.135

Abstract

Waveguide merupakan suatu alat yang berbentuk menyerupai selongsong persegi ataupun melingkar yang terbuat dari bahan konduktor tunggal. Alat tersebut dapat disisipi dielektrik untuk mengatur frekuensi tertentu atau konverter untuk mengubah mode dari gelombang yang digunakan. Penelitian ini melakukan implementasi konverter mode TE10 ke mode TMmn pada rectangular waveguide dan menggamati karakteristik dari vektor gelombang konverter serta parameter S11 dan S21. Proses pengujian dilakukan dengan mencoba beberapa rancangan dan membandingkan hasilnya, kemudian mengimplementasikannya pada alat. Simulasi dilakukan untuk mendapatkan hasil terbaik. Berdasarkan analisis dari proses simulasi menggunakan software ansoft HFSS, hasil terbaik didapatkan pada konverter mode TMmn parameter dengan rancangan double-trench belah ketupat dan frekuensi cut off 6.4 GHz. Nilai return loss sebesar -14.289 dB dan insertion loss sebesar -0.281 dB. Sedangkan pada rancangan konverter double-trench kembar didapatkan hasil frekuensi cut off sebesar 9.2 GHz dengan nilai return loss -12.878 dB dan nilai insertion loss -0.467 dB. Pada saat pengujian alat yang dilakukan menggunakan Vector Network Analyzer (VNA), frekuensi cut-off yang diperoleh adalah sebesar 7.03 GHz dengan return loss -12.68 dB, dan insertion loss -6.80 dB.
Klasterisasi Sumber Penyebaran Virus Covid-19 dengan Menggunakan Metode K-MEANS Di Daerah Kota Cimahi dan Kab. Bandung Barat M. Reza Hidayat; Arief Rachman
Jurnal Teknik: Media Pengembangan Ilmu dan Aplikasi Teknik Vol 19 No 2 (2020): Jurnal Teknik - Media Pengembangan Ilmu dan Aplikasi Teknik
Publisher : Fakultas Teknik - Universitas Jenderal Achmad Yani

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26874/jt.vol19no02.233

Abstract

The Covid-19 virus originated from the city of Wuhan in China. Transmission is very fast and rapid to various parts of the world including Indonesia. This study discusses the clustering of sources of the spread of the covid-19 virus using the k-means method using software for Cimahi City and West Bandung Regency. The purpose of this study is to obtain information about 5 clusters of the source of the Covid-19 virus, namely cluster 0 (offices), cluster 1 (places to eat), cluster 2 (houses), cluster 3 (shopping), and cluster 4 (public transportation). during May to July 2020 for Cimahi City and West Bandung Regency. The results can be concluded that the highest cluster 0 from Kab. West Bandung with an average of 0,05%, for cluster 1 the highest impact of covid-19 was from Kab. West Bandung with an average of 0,55%, for cluster 2 with an average of 0,02%, for cluster 3 the highest impact of covid-19 was from Kab. West Bandung with an average of 0,04%, for cluster 4 the highest impact of covid-19 was from Cimahi City with an average of 0.79%.
Pengaruh Kontaminan Air terhadap Tegangan Tembus Isolasi Cair Minyak Mineral dan Nabati sebagai Alternatif Isolasi Minyak Transformator Christiono; Miftahul Fikri; Dhami Johar Damiri; Muh. Rezha Safariansyah; Syahty Pratiwi; M. Reza Hidayat
Jurnal Teknik: Media Pengembangan Ilmu dan Aplikasi Teknik Vol 21 No 1 (2022): Jurnal Teknik - Media Pengembangan Ilmu dan Aplikasi Teknik
Publisher : Fakultas Teknik - Universitas Jenderal Achmad Yani

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

One of the effects of reduced transformer life is the frequent occurrence of disturbances, disturbances that can occur in the form of contamination of insulating oil which has an impact on transformer damage. To reduce the damage, a research was carried out, in this study it was carried out to see the effect of water contaminants contained in the insulation of transformer oil using the Breakdown Voltage method by looking at the value of the translucent voltage. There are 2 types of insulating oil used during testing, mineral, and vegetable oil, while the test equipment used is the BAUR Oil Tester DPA, with the standard IEC 60156:2018 test equipment. Which is adapted to the standard specification SPLN 49-1:1982 which states that new oil has a breakdown voltage value of 30 kV/2.5 mm. The results of the test show that the breakdown voltage value is influenced by water contaminants where the more contaminants contained, the faster the breakdown voltage value will decrease. This research can be an indication to maintain the transformer resistance.
Antena Helix Mode Axial untuk Frekuensi Kerja Radar S-Band M. Reza Hidayat; Aditya Febryana; Nivika Tiffany Somantri; Yussi Perdana Saputera
Jurnal Teknik: Media Pengembangan Ilmu dan Aplikasi Teknik Vol 22 No 1 (2023): Jurnal Teknik - Media Pengembangan Ilmu dan Aplikasi Teknik
Publisher : Fakultas Teknik - Universitas Jenderal Achmad Yani

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55893/jt.vol22no1.478

Abstract

This study designed an axial mode helix antenna with a working frequency used of 2.1 GHz, which has a return loss value of < -10 dB and VSWR < 1.3. The simulation was carried out using the CST studio suite 2020 software by designing a helix antenna from the calculation results to optimization of the helix antenna structure, namely the distance between the windings, the number of windings, the diameter of the windings, and the diameter of the ground plane until the simulation results are in accordance with the specifications of the desired parameters. Based on the final results of the return loss parameters and VSWR has met the designed specification standards, from the simulation results of the axial mode helix antenna, the results were obtained, namely at a return loss of -22 dB and at a VSWR value obtained 1.17. The results of the measurement of the axial mode helix antenna obtained the same result at a return loss of -22 dB and at VSWR 1.17 but the frequency value used in the measurement shifted to 2.45 GHz, this is not a problem because the s-band frequency can work from 2 GHz to 4 GHz.