Found 3 Documents
Search

Kegiatan Pelatihan untuk Meningkatkan Kesiapan Petugas Puskesmas Cibeureum dan Salawu di Tasikmalaya Terhadap Penerapan Teknologi UVC dan Teknologi Ozone sebagai Alat Sterilisasi Nundang Busaeri; Nurul Hiron; Prama Permana; Yuldan Faturahman; Nisa Khoerunisa
J-Dinamika : Jurnal Pengabdian Masyarakat Vol 6 No 2 (2021): December
Publisher : Politeknik Negeri Jember

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25047/j-dinamika.v6i2.2436

Abstract

Artikel ini membahas tentang  kegiatan pelatihan untuk peningkatan pengetahuan, penggunaan dan kewaspadaan dalam menggunakan teknologi UV-C dan Ozon sebagai alat atau media sterilisasi. Pelatihan ditujukan kepada petugas kesehatan di Puskesmas Cibeureum Kota Tasikmalaya dan Puskesmas Salawu di Kabupaten Tasikmalaya. Metode yang digunakan adalah Analisis situasi mitra, Pre-test, edukasi peserta melalui webinar, Post-test dan kesimpulan. Hasil dari pelaksanaan ini adalah penggunaan teknologi UVC dan ozon sebagai media sterilisasi memerlukan pelatihan agar masyarakat yang bekerja dibidang pelayanan kesehatan tidak mendapatkan dampak negatif dari teknologi tersebut. Dengan kuesioner yang terdiri dari tiga dimensi, yaitu pengetahuan umum, utilitas dan kewaspadaan dapat diketahui tingkat pengetahuan peserta dalam kesiapan penerapan teknologi tersebut di lapangan. Meskipun peserta mayoritas adalah pekerja pada pelayanan kesehatan, ternyata teknologi UVC dan Ozon merupakan teknologi yang belum begitu populer pada kalangan petugas kesehatan. Hal ini memberikan makna pentingnya pengenalan dan pelatihan teknologi baru yang dapat digunakan sebagai alat sterilisasi dan disinfektan dari bakteri dan virus, khususnya virus Covid-19
SISTEM KONTROL SUHU ELECTRIC MUFFLE FURNACE MENGGUNAKAN SENSOR THERMOKOPEL TYPE-K BERBASIS MIKROKONTROLLER ARDUINO UNO Farhan Arista Fhadillah; Asep Andang; Nundang Busaeri
Journal of Energy and Electrical Engineering (JEEE) Vol 4, No 2: 13 April 2023
Publisher : Teknik Elektro Universitas Siliwangi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37058/jeee.v4i2.6658

Abstract

Along with the development of the era, the furnace became a mandatory item in the material industry, the lack of domestic products caused the high price of heating stoves in this industry, especially in terms of learning methods, there was a need for developments in the field of technology that could make it easier, cheaper, and able to increase the productivity of human resources. Unstable temperature characteristics at high temperatures are an obstacle in this study, therefore a heater design is carried out using the PID control method. The main objective of this research is to stabilize the temperature at high temperatures at a low price. The components used in this study are Arduino Uno, Dimmer SCR 220 V 400 W, LCD, Push Button, Servo Motor, and RTC Module. To test the stability of the temperature, this research was carried out by testing the heater with empty objects in it, small objects (iron plates), and large objects (iron rods) and testing them at different temperatures, namely at 100oC, 200oC, 300oC and 400oC. From all the tests performed, the steady state error rate was not more than 5%.
ANALISIS PELUANG EFISIENSI MELALUI KONSERVASI ENERGI PADA SISTEM TATA UDARA DI GEDUNG RUMAH SAKIT UMUM NURHAYATI GARUT Nadya Aprilia; Nundang Busaeri; Andri Ulus Rahayu
E-JOINT (Electronica and Electrical Journal Of Innovation Technology) Vol. 4 No. 1 (2023): Vol. 4 No. 1 (2023): E-JOINT, Juni 2023
Publisher : Politeknik Negeri Cilacap

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35970/e-joint.v4i1.1925

Abstract

Penelitian membahas tentang konservasi energi pada sistem tata udara untuk meningkatkan efisiensi penggunaan energi listrik pada gedung karena penggunaan energi listrik pada gedung Rumah Sakit Umum Nurhayati 75% digunakan pada sistem tata udara. Tujuan penelitian ini adalah menganalisis konsumsi energi untuk mendapatkan penghematan energi pada sistem tata udara agar tercapainya konsumsi energi yang lebih efisien. Metode yang dilakukan pada penelitian ini adalah konservasi energi dengan audit energi dilakukan perhitungan IKE, dan peluang upaya penghematan energi pada sistem tata udara. Hasil yang diperoleh pada penelitian ini adalah nilai intensitas konsumsi energi (IKE) pada Rumah Sakit Umum Nurhayati untuk bangunan non AC sebesar 28,68 kWh/m2/tahun termasuk kategori “efisien” sedangkan bangunan ber AC termasuk kriteria “agak boros” yaitu sebesar 183,16 kWh/m2/tahun. Besarnya konsumsi energi sistem tata sebesar 470801 kWh/tahun dari total penggunaan energi pada gedung. Peluang penghematan energi yang direkomendasikan dengan hasil paling efisien adalah menggunakan jenis AC inverter hemat energi dan didapatkan penghematan sebesar 209244,2 kWh/tahun atau 44% per tahun, dan nilai IKE setelah penghematan menjadi 101,7 kWh/m2/tahun menjadi kategori “efisien” dengan payback period selama 1 tahun 8 bulan dari penghematan yang dilakukan.