Inovasi Sambungan Mekanis Menggunakan Clamp Baja Untuk Tulangan Beton Parmo, Parmo; Tavio, Tavio
EMARA Indonesian Journal of Architecture Vol 1, No 2 (2015)
Publisher : Faculty of Science and Technology State Islamic University Sunan Ampel Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (548.037 KB)

Abstract

Pertumbuhan perkotaan di Indonesia beberapa waktu terkakhir cenderung lebih mengarah pada overground space. Hal ini disebabkan karena populasi penduduk perkotaan mengalami peningkatan yang signifikan dan tidak sebanding dengan lahan yang tersedia. Banyaknya bangunan tinggi dan gedung pencakar langit juga menandai fenomena tersebut. Namun, bangunan tinggi dan gedung pencakar langit memiliki potensi terhadap bahaya gempa bumi, lebih lagi Indonesia adalah termasuk wilayah yang rawan terjadi gempa bumi. Dalam perencanaan bangunan tahan gempa dua hal pokok yang perlu diperhatikan adalah kekuatan dan daktilitas. Kemampuan berdeformasi dan kekuatan pada sambungan antar tulangan menjadi pertimbangan dalam desain struktur tahan gempa. Dari hasil pengujian tarik clamp baja untuk sambungan mekanik tulangan D13 diperoleh yield strength 270.69 Mpa, ultimate tensile strength 351.45 Mpa dan beban maksimum 4757 kg serta elongation 40%. Sedangkan untuk sambungan mekanik tulangan D16 diperoleh yield strength 217.80 Mpa, ultimate tensile strength 327.605 Mpa dan beban maksimum 6717 kg serta elongation 32%. Pada penelitian ini digunakan 2 (dua) buah clamp baja. Namun, untuk memeperoleh hasil yang lebih baik perlu penambahan jumlah clamp dan peningkatan kualitas material clamp baja.
Penilaian Kondisi Bangunan Gedung Sekolah Dasar Negeri Studi Kasus di Sekolah Dasar Negeri Se-Kabupaten Madiun Parmo, Parmo; Sucipto, Mohammad Hadi; Sumarkan, Sumarkan
EMARA Indonesian Journal of Architecture Vol 2, No 1 (2016)
Publisher : EMARA Indonesian Journal of Architecture

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1223.112 KB)

Abstract

Facilities and infrastructure are important elements to achieve the successful education and teaching process. The procurement of adequate and standardized buildings become an effort to comply with the minimum standards of infrastructure required by the government. This study focus on conducting an analyzis the damage level at State Primary School (SDN) buildings in Madiun regency.Building condition assessment conducted through a direct surveys and then proceed by weighting the data to obtain the level of damage categorized as good, minor, moderate and heavily damaged . Among the 431 of state primary school buildings surveyed, 36.53% of the classrooms in a minor damage while 25.42% others considered heavily damaged. For the teachers office, 38.04% were in a minor damage, while 23.23% others considered heavily damaged. For  the library buildings, 38.14% of them considered in a minor damage and 24.53% others heavily damaged. For teacher latrines condition, 49.53% of teacher latrines considered heavily damaged, while 24.03% were moderate damage. While 49.82% of student latrines were heavily damaged and 23.49% others considered in a moderate damage.From the assessment, it can be concluded that the latrines facility repairment, both for teachers and students, should become top priority for the local government in the implementation of school quality improvement programs.buildings condition, level of damage, primary school building <w:LsdException Locked="false" Priority="21" QFormat="true" Name="Intense Emphasis"
Perkuatan Struktur Beton Bertulang Dengan Metode FRP dan Concrete Jacketing Parmo, Parmo; Hakim, Abdul; Yusrianti, Yusrianti; Wicaksono, Bagus Gilbran Antoni
MEDIA KOMUNIKASI TEKNIK SIPIL Volume 31, Nomor 1, JULI 2025
Publisher : Department of Civil Engineering, Diponegoro University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14710/mkts.v31i1.72695

Abstract

Applying the latest building earthquake resistance codes, SNI 1726:2019 to the reinforced concrete structure of the Islamic Center Building shows several column and beam elements that required strengthening, including beam B1, column K-Bordes, and column K3. This case study research aims to determine the appropriate strengthening method, the thickness of the additional column dimensions with the concrete jacketing method, and the number of FRP layers for columns and beams. Systematic steps in the study process starting from collecting existing data, field investigation, evaluation of structures in accordance with ASCE 41-17, structural modeling with SAP2000, and data analysis. The analysis showed that Column K-Bordes was confined with a thickness of 100 mm using concrete jacketing, Column K3 was strengthened with one layer of GFRP at the plastic hinge, and Beam B1 was strengthened with two layers of GFRP at the support area. Pull-off test showed GFRP adhesion strength values to concrete of 3.80 MPa (Beam B1) and 2.50 MPa (Column K3). This approach proves the effectiveness of the combined reinforcement method in increasing the structural capacity according to the latest earthquake codes.