PENGARUH PEMBEBANAN TERHADAP ARUS MOTOR EG-530AD-2F Zaenal Arifin
Jurnal DISPROTEK Vol 10, No 1 (2019)
Publisher : Universitas Islam Nahdlatul Ulama Jepara

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.34001/jdpt.v10i1.930

Abstract

All processes that work must be controlled by a system that can be controlled with the aim of increasing efficiency and minimizing the risk of errors. Likewise the production process with a system that can be controlled, in this case in the process of separating goods based on certain criteria as needed with PLC as the basis of control will make a combination of a complex and interrelated system to improve the performance of the system. Analysis of loading prototype of a separator system based on PLC-based altitude, with a power supply voltage of 12 Volt DC to run a prototype system, it was found that the load that can be passed on each data conveyor loading on 12volt dc motor conveyor performance eg-530ad-2f is a load starting from 10-120 gr where the drive used is a 12 Volt DC motor with coupled by a 5mm elastic rubber van, with overall required current of 2.15 A, the required voltage is 12Vdc ± 8.99%.
SISTEM MONITORING PEMERATAAN SUHU PADA INKUBATOR TELUR BERBASIS NODE MCU Zaenal Arifin; Dias Prihatmoko; Safrizal Safrizal; Saharul Alim; Nazar Choir
Jurnal Disprotek Vol 14, No 1 (2023)
Publisher : Universitas Islam Nahdlatul Ulama Jepara

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.34001/jdpt.v14i1.4068

Abstract

The development of tools that are increasingly modern from time to time where one of them is a poultry egg incubator, temperature is a major factor in hatching poultry eggs, the market demand is greater than production. By taking advantage of technological developments, breeders can use egg incubators. The purpose of this tool is to create temperature control in the box that is evenly distributed in the poultry egg incubator so that hatching success is higher. The method used is development by searching for material, designing tools and then making egg incubators with size (50x40x50) cm, and installing four Dht-11 sensors at each corner of the incubator, data collection to analysis. Testing the DHT-11 sensor at a setting point of 38oC from the four sensors, during the daytime test it takes 10 minutes to reach a temperature of 38oC from the four sensors, and the temperature is stable in the range of 37oC-39oC. The results of this study are in the form of testing the DHT-11 sensor at night, it takes 12 minutes for the four sensors to reach the setting point of 38oC, from testing for one hour with data collection every two minutes the temperature is stable in the range of 37oC-39oC from the four sensors installed on the four corners of the rack on the egg incubator. Tests of ultrasonic sensors one and two get readings if the distance is less than 40 cm then the buzzer will light up. Telegram testing results where the temperature status in the egg incubator box can be accessed at any time.
AUDIT ENERGI SISTEM PENCAHAYAAN DAN SISTEM TATA UDARA PADA GEDUNG ADMIN PLTU TANJUNG JATI B UNIT 3 & 4 Saharul Alim; Zaenal Arifin; Muhammad Alif Najih; Aji Wicaksono
Jurnal Disprotek Vol 12, No 2 (2021)
Publisher : Universitas Islam Nahdlatul Ulama Jepara

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.34001/jdpt.v12i2.2638

Abstract

This study will analyze the suitability of the lighting and air conditioning systems installed with the provisions of SNI-6197-2011 and SNI-6390-2011, the value of energy consumption intensity in all buildings will be calculated and analyzed according to the regulation of the minister of energy and mineral resources 13 of 2012, and estimate possible opportunities. The results show that the value of energy consumption intensity is included in the very wasteful criteria, namely 50.38 kW/m2, so it is necessary to increase the energy audit, the most energy saving that is most likely to be done is high costs by replacing lighting equipment and air conditioning systems, for lighting systems by changing the type of lighting. 36W 36W TL lamps, 14.7W LED tube lamps and 18W PL lamps become 10W LED bulb lamps, while for the air conditioning system by replacing non-inverter coolers into inverter coolers and adjusting the cooling capacity according to the BTU/h needs of each room, thus saving electrical energy which is obtained is 138,399.49 kWh per month or if converted into Rp. 164,762,338.54 and the intensity of energy consumption is reduced to 13.66 kWh/m2 which is classified as quite efficient.