Vera Roni Setiawan
Magister Teknik Kimia Universyitas Syiah Kuala Banda Aceh

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

PENGGUNAAN MODEL RASCH UNTUK MENDETEKSI KUALITAS SOAL KIMIA SMA PADA UJIAN AKHIR SEMESTER (UAS) Pohan, Lisa Ariyanti; Ledya, Kiki; Setiawan, Vera Roni; Darmana, Ayi; Suyanti, Retno Dwi
Eksakta : Jurnal Penelitian dan Pembelajaran MIPA Vol 7, No 2 (2022): Eksakta : Jurnal Penelitian dan Pembelajaran MIPA
Publisher : Fakultas Keguruan Dan Ilmu Pendidikan, UM-Tapsel

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31604/eksakta.v7i2.280-289

Abstract

This study was conducted to analyze the questions for the Final Semester Examination (UAS) which were used to measure students' abilities in chemistry subjects in the science department of class XII of SMA Negeri 2 Lhokseumawe. Participants in this subject consist of 75 students. The questions given are in the form of multiple choice questions totaling 25 items related to integrated calculation and theory material in chemistry subject matter from class X, XI and XII. The Model Rasch is used to obtain fit items. This analysis was carried out with the help of Winsteps software. From the output of the Winsteps program, the results of the final semester exam (UAS) in chemistry subjects were tested using the Model Rasch to produce data, namely the item score (item reliability) of 0.77 with consistent information that the answers were in the sufficient category and the reliability of the person (person reliability) was 0.95. , with information on the quality of the items in the special category and Cronbach's alpha value of 0.85. The Outfit Mean Square Statistic (Outfitt MNSQ) value for the suitability of the questions and the level of difficulty of the questions is (1.54 = 1.5) in the person column. The Outfit Z Standard (Outfit ZSTD) value for the suitability of the questions and the level of difficulty of the questions in the item column is 0.55. The Outfit Mean Square Statistic (Outfitt MNSQ) value for students' abilities is 1.36 in the person column. The Outfit Z Standard (Outfit ZSTD) value for students' abilities in the item column is 0.19. The test questions used for chemistry subjects are 25 questions, after being tested with a fit Model Rasch, 18 questions (72%) can be used and as many as 7 questions (28%) are not fit or cannot be used.
Pengolahan Limbah Cair Laundry Menggunakan Membran Selulosa Diasetat Berbasis Selulosa Pulp Kayu Sengon (Paraserianthes falcataria) Setiawan, Vera Roni; Rosnelly, Cut Meurah; Darmadi, Darmadi
Jurnal Rekayasa Kimia & Lingkungan Vol 9, No 3 (2013): Jurnal Rekayasa Kimia & Lingkungan
Publisher : Chemical Engineering Department, Syiah Kuala University, Banda Aceh, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23955/rkl.v9i3.782

Abstract

The improvement of laundry activity brought a negative effect on the environment because laundry wastewater have a high content pollutants such as phosphate, surfactants, mineral, nitrogen, COD and other components, so the treatment is needed before being discharged into terristorial water. Laundry wastewater treatment has been conducted by membrane technology. Preparation of cellulose diacetate membranes with ultrafiltration process had be done by phase inversion using dimethylformamide (DMF) as a solvent. The filtration experiment showed that the highest membrane flux was 77,408 L/m2.h at TMP 3 bar. While the lowest flux at TMP 1 bar was 55.649 L/m2.h. Rejection of membrane ultrafiltration for parameters of COD, phosphate, and surfactant were 67%, 72%, and 63% respectively.Keywords: cellulose diacetate membranes, laundry wastewater, flux, rejection