Imam Arif Raharjo
Pendidikan Teknik Elektro, Fakultas Teknik, Universitas Negeri Jakarta

Published : 10 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 10 Documents
Search

PEMBUATAN MEDIA PEMBELAJARAN BERBASIS VIDEO MATA KULIAH PENGATURAN MOTOR (STUDI PADA PROGRAM STUDI PENDIDIKAN TEKNIK ELEKTRO, FAKULTAS TEKNIK, UNIVERSITAS NEGERI JAKARTA) Diah Yuni Purwitaingsih; Imam Arif Raharjo; Massus Subekti
Journal of Electrical Vocational Education and Technology Vol 1 No 1 (2016): Journal Of Electrical Vocational Education and Technology
Publisher : Fakultas Teknik Universitas Negeri Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21009/JEVET.0011.07

Abstract

Abstract. This research aimed to create and utilize video-based learning media on motor control course and also to determine whether the video-based learning media on motor control course is effective or not. The making of the video-based learning media using several stages, namely, literature study, analysis needs, product planning, product making, instrument making feasibility and feasibility studies that are conducted by the experts, media specialists and students in order to determine the feasibility of the media created. Furthermore, to test the effectiveness of video-based learning media on motor control course, students are given the post-test questions that the validity and reliability have previously been tested by using an experimental model. The results of the feasibility test got a score > 80%, subject experts got a score of 94.23%, media experts 91,66%, and students 86.13%. The results of the feasibility test obtained, video-based learning media on motor control course is said to be very good and fit for use as a media of learning. The average value of students post test using a video-based learning media is 83, while students who do not use a video-based learning media have an average of 80.56. These data showed that value of post test results of motor control course that uses video-based learning media is higher than value of post test results that does not use a video-based learning media. The difference in post test results show that a video-based learning media on motor control course is an effective media of learning. Abstrak Penelitian ini bertujuan untuk membuat dan memanfaatkan media pembelajaran berbasis video mata kuliah pengaturan motor untuk mengetahui apakah media pembelajaran berbasis video ini efektif atau tidak. Pembuatan media pembelajaran berbasis video ini menggunakan beberapa tahapan yaitu, studi literatur, analisis kebutuhan, perencanaan produk, pembuatan produk, pembuatan instrumen uji kelayakan dan uji kelayakan yang dilakukan oleh ahli materi, ahli media dan mahasiswa guna mengetahui kelayakan media yang dibuat. Selanjutnya untuk menguji keefektifan dari media pembelajaran berbasis video mata kuliah pengaturan motor, mahasiswa diberikan soal post test yang sebelumnya sudah di uji validitas dan reabilitasnya dengan menggunakan model eksperimen. Hasil uji kelayakan mendapatkan skor >80% yaitu ahli materi mendapat skor sebesar 94,23%, ahli media 91,66%, dan mahasiswa 86,13%. Dari hasil tersebut, media pembelajaran berbasis video mata kuliah pengaturan motor sangat baik dan layak digunakan sebagai media pembelajaran. Rata-rata nilai post test mahasiswa yang menggunakan media pembelajaran berbasis video sebesar 83, sedangkan mahasiswa yang tidak menggunakan media pembelajaran berbasis video memiliki rata-rata sebesar 80,56. Dari data tersebut menunjukkan bahwa hasil nilai post test yang menggunakan media pembelajaran berbasis video lebih tinggi dibandingkan dengan hasil nilai post test yang tidak menggunakan media pembelajaran berbasis video. Dari perbedaan hasil post test tersebut menunjukan bahwa media pembelajaran berbasis video mata kuliah pengaturan motor efektif digunakan sebagai media pembelajaran.
ANALISIS SISTEM SUPLAI LISTRK DARI PLN DAN PLTS PADA GEDUNG WISMA (SUATU STUDI PENELITIAN DI GEDUNG UTAMA PUSDIKLAT CIRACAS) Yehezkiel Yuniar Putra; Suyitno; Imam Arif Raharjo
Journal of Electrical Vocational Education and Technology Vol 1 No 1 (2016): Journal Of Electrical Vocational Education and Technology
Publisher : Fakultas Teknik Universitas Negeri Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21009/JEVET.0011.08

Abstract

Abstract To solved Indonesian electricity problems have to do attempts to locate and exploit new sources of renewable electricity and the alternatively one of these is combines the power source of the PLN and also alternative power source with PLTS, where both the source of electrical energy will work simultaneously and synchronized. This research aims to know the electric supply system of the PLN and PLTS in homestead building in terms of synchronizing two source. Research conducted at the Pusdiklat KEBTKE Ciracas, East Jakarta on 3 June to 4 June 2016. The method used in this research is quantitative descriptive method. Stages of the process of research done by doing a field observation and data collection techniques. Research instrument in the form of a measuring tool, graphs and tables of measurements data. From the measurement data, the average voltage difference on phase R is 0,396 Volts or 0,18% of main voltage PLN, the average voltage difference on phase S is 0,22 Volt or 0,1% of main voltage PLN, the average voltage difference on phase T is 0,244 Volts or 0,11% of main voltage PLN. While the average difference in the frequency of PLN and PLTS is 0,036 Hz. Phase sequence in PLTS on-grid system in homestead building is accordance with the main system PLN, i.e. R-R, S-S, and T-T. Then, the average difference in phase angle on the phase R is 9,76° with the maximum phase angle value is 26,4°, the average difference in phase angle on the phase S is 4,65°, with the maximum phase angle values is 10,1°, the average difference in the phase angle on the phase T is 7,73 ° with the maximum phase angle value is 13,8°. When seeing the four sync indicators on the data, then the system of PLTS on-grid is already synchronized with system of PLN. Abstrak Untuk mengatasi permasalahan kelistrikan di Indonesia perlu dilakukan upaya untuk mencari dan memanfaatkan sumber listrik altenatif baru dan terbarukan yang salahsatunya adalah memadukan sumber listrik dari PLN dan juga sumber listrik alternatif dengan PLTS, dimana kedua sumber energi listrik ini akan bekerja secara bersamaan dan tersinkronisasi. Penelitian ini bertujuan untuk mengetahui sistem suplai listrik dari PLN dan PLTS pada gedung wisma dari segi sinkronisasi dua pembangkit. Penelitian dilaksanakan di Pusdiklat KEBTKE Ciracas, Jakarta Timur pada tanggal 3 Juni hingga 4 Juni 2016. Metode yang dipakai pada penelitian ini adalah metode deskriptif kuantitatif. Tahapan proses penelitian yang dilakukan dengan melakukan observasi lapangan dan teknik pengumpulan data. Instumen penelitian berupa alat ukur, grafik dan tabel data pengukuran. Dari data pengukuran, rata-rata selisih tegangan pada fasa R adalah 0,396 Volt atau 0,18% dari tegangan utama PLN, rata-rata selisih tegangan pada fasa S adalah 0,22 Volt atau 0,1% dari tegangan utama PLN, rata-rata selisih tegangan pada fasa T adalah 0,244 Volt atau 0,11% dari tegangan utama PLN. Sedangkan rata-rata selisih frekuensi PLN dan PLTS adalah 0,036 Hz. Urutan fasa pada sistem PLTS on-grid di gedung wisma sesuai dengan sistem utama PLN, yaitu R-R, S-S, dan T-T. Kemudian, rata-rata selisih sudut fasa pada fasa R adalah 9,76° dengan nilai sudut fasa maksimum 19,7°, rata-rata selisih sudut fasa pada fasa S adalah 4,65° dengan nilai sudut fasa maksimum 10,1°, rata-rata selisih sudut fasa pada fasa T adalah 7,73° dengan nilai sudut fasa maksimum 13,8°. Bila melihat keempat indikator sinkron pada data, maka sistem PLTS on-grid sudah tersinkronisasi dengan sistem PLN.
PENGARUH PENGGUNAAN MEDIA PEMBELAJARAN TRAINER CONTROL MOTOR TERHADAP HASIL BELAJAR INSTALASI MOTOR LISTRIK Nobby Sail Andi Supu; Irzan Zakir; Imam Arif Raharjo
Journal of Electrical Vocational Education and Technology Vol 3 No 2 (2018): Journal Of Electrical Vocational Education and Technology
Publisher : Fakultas Teknik Universitas Negeri Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21009/JEVET.0032.04

Abstract

The research is intended to investigate the effect of learning media Trainer Control Motor to students’ learning outcomes in installation of electric motor subject . The research used quantitative research with quasy experimental method. This research used two groups to be investigated,which are experimental group that was given the Trainer Control Motor for learning media and the other group that wasn’t given the Trainer Control Motor learning media. The data collection process was done by giving the two groups post test. The collected data was processed by using t-test after it met the standard requirements and was homo-gen. The finding shows that the value tcount > ttable that is 8,225 > 2,001 with 0,05 significant level. Accordingly, Ho was rejected and Hi is accepted which means there is a difference between experimental class’ learning outcomes post-test and controlled class’ learning outcomes post test. Based on the t-test measurement and improvement of learning outcomes, it can be concluded that there is an effect of Trainer Control Motor media learning to the students’ learning outcomes in installation of electric motor subject. Abstrak Penelitian ini bertujuan untuk mengetahui pengaruh media pembelajaran Trainer Control Motor terhadap hasil belajar. Jenis penelitian yang digunakan adalah penelitian kuantitatif, dengan metode quasy eksperimental. Pada penelitian digunakan dua kelompok yang akan diteliti, yakni kelompok eksperimen yang diberi perlakuan dengan diberikan media pembelajaran dengan Trainer Control Motor dan kelompok satu lagi diberi perlakuan dengan tidak memberian media pembelajaranTrainer Control Motor. Proses pengumpulan data dilakukan dengan post-test pada kedua kelas. Data yang telah terkumpul akan diolah dengan uji-t setelah data memenuhi persyaratan normal dan homogen. Hasil penelitian menunjukkan bahwa thitung ˃ ttabel, yakni 8,225>2,001 dengan signifikansi 5%. Maka Ho ditolak dan Hi diterima yang artinya terdapat perbedaan antara hasil belajar post-test kelas eksperimen dengan hasil belajar post-test kelas kontrol. Berdasarkan hasil perhitungan uji-t, maka dapat disimpulkan bahwa terdapat pengaruh media pembelajaran Trainer Control Motor terhadap hasil belajar instalasi motor listrik.
UJI KELAIKAN INSTALASI LISTRIK ASRAMA MAHASISWA DI JAKARTA (STUDI KASUS DI ASRAMA MAHASISWA ISLAM SUNAN GUNUNG JATI DAN ASRAMA MAHASISWA ISLAM SUNAN GIRI) Raja Ingan Budi; Massus Subekti; Imam Arif Raharjo
Journal of Electrical Vocational Education and Technology Vol 3 No 2 (2018): Journal Of Electrical Vocational Education and Technology
Publisher : Fakultas Teknik Universitas Negeri Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21009/JEVET.0032.09

Abstract

The purpose of this research is to discover worthiness of electrical installation in Sunan Gunung Jati Moslem College Student Dormitory and Sunan Giri Moslem College Student Dormitory based on PUIL 2011 standardization. This research uses qualitative method by using data table and so on analyze based on PUIL 2011 standardization. Data analysis technique used is descriptive analysis. In preview results/observation results the lowest score (No) is 0, the highest score (Yes) is 1. These data results used interval as guidance feasibility test of electrical instalation at college student dormitory. The aim of using interval for quantify amount of the lowest score (No) which is obtained. If the lowest score (No) which is obtained more, so the end result is No Operational Worthiness (TLO) but if the highest score (Yes) which is obtained more, so the end result is Operational Worthiness (LLO). The conclusion of this research is electrical installation properness, component selection of electrical instalation, and utilization of Mini Circuit Breaker are appropiate based on PUIL 2011 standardization. Isolation resistance in Sunan Gunung Jati Moslem College Dormitory is 200 MΩ and it’s quite good. Isolation resistance in Sunan Giri College Dormitory is 1,3 MΩ and it’s fairly good. Both Sunan Gunung Jati Moslem College Student Dormitory and Sunan Giri Moslem College Student Dormitory there is no grounding resistance. To consider about electrical safety factor such as Grounding and PE Conductor Protection. So the end results in Sunan Gunung Jati Moslem College Student Dormitory which is the lowest score (No) that dormitory got is 13 point or No Operational Worthiness (TLO) and Sunan Giri Moslem College Student Dormitory which is the lowest score (No) that dormitory got is 12 point or No Operational Worthiness (TLO). Abstrak Tujuan penelitian ini yaitu untuk mengetahui kelaikan instalasi listrik Asrama Mahasiswa Islam Sunan Gunung Jati dan Asrama Mahasiswa Islam Sunan Giri berdasarkan standar PUIL 2011. Penelitian ini menggunakan metode kualitatif dengan menggunakan form tabel pengumpulan data yang selanjutnya dianalisis sesuai dengan standar PUIL 2011. Teknik analisis data yang digunakan yaitu analisis deskriptif. Dalam tabel hasil pengamatan skoring terendah (Tidak) diberi nilai 0, skoring tertinggi (Ya) diberi nilai 1. Pada pengolahan hasil penelitian digunakan rentang interval sebagai acuan status kelaikan asrama mahasiswa tersebut. Penetuan rentang interval ini digunakan untuk mengukur banyaknya skoring terendah (Tidak) yang diperoleh. Jika skoring terendah (Tidak) yang diperoleh banyak maka hasil penelitiannya Tidak Laik Operasi (LLO) namun jika skoring terendah (Tidak) yang diperoleh sedikit dengan kata lain skoring tertinggi (Ya) yang diperoleh banyak maka hasil penelitiannya Langsung Laik Operasi (LLO). Kesimpulan dari penelitian ini adalah kelengkapan pemasangan dan pemilihan komponen perlengkapan listrik serta pengaman MCB telah sesuai dengan standar PUIL 2011. Tahanan Isolasi pada Asrama Mahasiswa Islam Sunan Gunung Jati Matraman bernilai 200 MΩ dan tergolong baik sedangkan Tahanan Isolasi pada Asrama Mahasiswa Islam Sunan Giri bernilai 1,3 MΩ dan tergolong cukup baik. Pada penelitian ini tidak terdapatnya sistem pembumian. Mengingat faktor materi uji keselamatan ketenagalistrikan seperti proteksi sistem tak langung dan proteksi PE tidak terdapat dilapangan. Maka hasil akhir pada penelitian ini adalah pada Asrama Mahasiswa Islam Sunan Gunung Jati Matraman status kelaikannya Tidak Laik Operasi (TLO) dengan banyaknya poin skor terendah (tidak) yang didapatkan 13 poin dan hasil akhir pada Asrama Mahasiswa Islam Sunan Giri Rawamangun status kelaikannya Tidak Laik Operasi (TLO) dengan banyaknya poin skor terendah (tidak) yang didapatkan 12 poin.
ANALISIS HUBUNG SINGKAT PADA GARDU INDUK 150/20 KV (STUDI KASUS DI GARDU INDUK GANDUL, CINERE) Cilvia Calnela; Suyitno; Imam Arif Raharjo
Journal of Electrical Vocational Education and Technology Vol 4 No 2 (2019): Journal Of Electrical Vocational Education and Technology
Publisher : Fakultas Teknik Universitas Negeri Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21009/JEVET.0042.09

Abstract

This study aims to determine the difference in short circuit current with manual calculation and ETAP 12.60 Simulation in to know the suitability of capacity circuit breaker Substasion 150/20 kV at Gandul. The used method is qualitative descriptive method. The subject that will be studied is short circuit on the substation 150/20 kV Gandul Cinere. The research was conducted by using is manual calculation and software ETAP 12.60 simulation. The results obtained is differences of the short circuit current is not significant between the manual calculation and software ETAP 12.60 simulation in three conditions include 0.572% for the conditions of short circuit fault of one phase to ground, 0.884% for the conditions of short circuit fault of phase to phase and last 0.884% for the short circuit fault of three phase. Furthermore, the result of the calculation of the short circuit current will be used as an indicator of a determinant of the suitability of the capacity circuit breaker substation 150/20 kV at Gandul , obtained that a comparison of the rating circuit breaker installed (existing) is great against the result of the election of the rating circuit breaker base on manual calculation. So it can be concluded that the circuit breaker beinstalled on the substation 150/20 KV at Gandul, has a capacity that suits your needs and still fit for use. ABSTRAK Penelitian ini bertujuan untuk mengetahui perbedaan besar arus hubung singkat antara perhitungan manual dan simulasi ETAP Power Station 12.6 serta untuk mengetahui kesesuaian kapasitas pemutus tenaga GI Gandul 150/20 kV. Metode yang digunakan adalah deskriptif kualitatif. Subjek pada penelitian ini adalah arus hubung singkat pada Gardu Induk 150/20 kV Gandul Cinere. Penelitian dilakukan menggunakan perhitungan manual dan simulasi software ETAP Power Station 12.6. Hasil penelitian diperoleh bahwa perbedaan hasil arus hubung singkat yang tidak signifikan antara perhitungan manual dan simulasi software ETAP Power Station 12.6 dalam tiga kondisi meliputi 0.572% untuk kondisi gangguan hubung singkat salah satu fasa ketanah, 0.884% untuk kondisi gangguan arus hubung singkat fasa ke fasa dan terakhir 0.884% untuk gangguan arus hubung singkat tiga fasa. Selanjutnya, hasil perhitungan arus hubung singkat tersebut akan digunakan sebagai indikator penentu kesesuaian kapasitas pemutus PMT (Circuit Breaker) GI Gandul 150/20 kV, diperoleh bahwa perbandingan rating pemutus PMT yang terpasang (existing) lebih besar terhadap hasil pemilihan rating pemutus PMT berdasarkan perhitungan manual. Sehingga dapat disimpulkan bahwa pemutus tenaga yang terpasang pada di GI Gandul 150/20 kV memiliki kapasitas yang sesuai dengan kebutuhan dan masih layak digunakan.
ANALISIS ARUS INRUSH SAAT SWITCHING KAPASITOR BANK PADA BUSBAR 2 (Suatu Studi DI PT.PLN (persero) GARDU INDUK GANDUL) Irfan Hidayat; Nur Hanifah Yuninda; Imam Arif Raharjo
Journal of Electrical Vocational Education and Technology Vol 4 No 1 (2019): Journal Of Electrical Vocational Education and Technology
Publisher : Fakultas Teknik Universitas Negeri Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21009/JEVET.0041.03

Abstract

Irfan Hidayat, Analysis of Inrush Flow when Switching Bank Capacitors on Busbar 2. Thesis. Jakarta, Electrical Engineering Education Study Program, Faculty of Engineering, Jakarta State University 2018. Supervisor: Nur Hanifah Yuninda, ST., MT., And Imam Arif Raharjo, S.Pd., MT. This study aims to analyze the inrush current when switching bank capacitors. The inrush current can be defined as the magnitude of the current surge that first appears in the circuit, when the circuit is connected to the load. As with transient phenomena, inrush currents in electrical circuits are considered undesirable. In every electrical equipment there must be an inrush current. The inrush current is dangerous for the system when the peak value of the inrush current is very large. To reduce the value of inrush current using a series reactor. The research method used in this study is the experimental method using a research design with pre-experimental design used is one-group pretest-posttest design. In collecting data, the circuit inductance data is collected and on the bank capacitors. To analyze how much the inrush current and frequency before and after the addition of a series reactor. The results showed inrush current when switching capacitor banks before the addition of series reactors exceeded the IEEE Std C37.012-2005 standard where the inrush current is allowed 100 times the rms current. The value of the inrush current and frequency at each step before the addition of the series reactor is: step 1 = 16.29 kA, 4.16 kHz; Step 2 = 289.7 kA, 147.32 kHz; Step 3 = 349.22 kA, 133.2 kHz; Step 4 = 372.47 kA, 126.28 kHz; Step 5 = 386.03 kA, 122.7 kHz; Step 6 = 410.146 kA, 125.15 kHz. The value of the inrush current and frequency at each step after the addition of the series reactor is: step 1 = 1.1 kA, 0.2 kHz; Step 2 = 26.56 kA, 13.5 kHz; Step 3 = 30.68 kA, 11.7 kHz; Step 4 = 36.35 kA, 12.3 kHz; Step 5 = 41.08 kA, 13.05 kHz; Step 6 = 45.27 kA, 13.8 kHz. So that the inrush current is in accordance with the IEEE Std C37.012-2005 standard. ABSTRAK Irfan Hidayat, Analisis Arus Inrush saat Switching Kapasitor Bank pada Busbar 2. Skripsi. Jakarta, Program Studi Pendidikan Teknik Elektro Fakultas Teknik Universitas Negeri Jakarta 2018. Dosen Pembimbing: Nur Hanifah Yuninda, ST., MT., dan Imam Arif Raharjo, S.Pd., MT. Penelitian ini bertujuan untuk menganalisis arus inrush pada saat switching kapasitor bank. Arus inrush dapat didefinisikan sebagai besarnya lonjakan arus pertama kali muncul pada rangkaian, saat rangkaian terhubung dengan beban. Sama halnya dengan fenomena transien, arus inrush dalam rangkaian listrik dianggap sebagai hal yang tidak diinginkan. Pada setiap peralatan listrik pasti terjadi arus inrush. Arus inrush berbahaya bagi sistem ketika nilai puncak arus inrush terjadi sangat besar. Untuk mereduksi besar nilai arus inrush menggunakan reaktor seri. Metode penelitian yang digunakan pada penelitian ini adalah metode eksperimen menggunakan rancangan penelitian dengan desain pre-experimental yang digunakan adalah one-group pretest-posttest design. Pada pengumpulan data, dilakukan pengambilan data induktansi rangkaian dan pada kapasitor bank. Untuk menganalisis seberapa besar arus inrush dan frekuensi sebelum dan sesudah penambahan reaktor seri. Hasil penelitian menunjukan arus inrush saat switching kapasitor bank sebelum penambahan reaktor seri melebihi standart IEEE Std C37.012-2005 dimana arus inrush yang di ijinkan 100 kali arus rms. Besar nilai arus inrush dan frekuensi pada setiap step sebelum penambahan reaktor seri sebesar: step 1 = 16,29 kA, 4,16 kHz; Step 2 = 289,7 kA, 147,32 kHz; Step 3 = 349,22 kA, 133,2 kHz; Step 4 = 372,47 kA, 126,28 kHz; Step 5 = 386,03 kA, 122,7 kHz; Step 6 = 410,146 kA, 125,15 kHz. Besar nilai arus inrush dan frekuensi pada setiap step setelah penambahan reaktor seri sebesar: step 1 = 1,1 kA, 0,2 kHz; Step 2 = 26,56 kA, 13,5 kHz; Step 3 = 30,68 kA, 11,7 kHz; Step 4 = 36,35 kA, 12,3 kHz; Step 5 = 41,08 kA, 13,05 kHz; Step 6 = 45,27 kA, 13,8 kHz. Sehingga arus inrush sesuai dengan standart IEEE Std C37.012-2005.
PENGARUH DISTORSI HARMONISA TERHADAP KINERJA TRIP MINIATURE CIRCUIT BREAKER TIPE C 2A, 4A, DAN 6A DENGAN SUMBER TEGANGAN PLN DAN GENSET Unfa Solfiani; Purwanto Gendroyono; Imam Arif Raharjo
Journal of Electrical Vocational Education and Technology Vol 4 No 1 (2019): Journal Of Electrical Vocational Education and Technology
Publisher : Fakultas Teknik Universitas Negeri Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21009/JEVET.0041.05

Abstract

The purpose of this study was to determine the effect of harmonic distortion with harmonic load on the performance of trip Type C Flow Miniature circuit breakers 2A, 4A, and 6A The method used is descriptive quantitative method. The research subjects to be examined are miniature circuit breakers. In collecting data, carried out harmonic load population testing and testing with a Power Quality Analyzer with a voltage source PLN and Genset, the results of MCB samples obtained were analyzed for trip characteristics referring to SPLN 108 : 1993 and IEEE. The results showed that from testing trip characteristics using harmonic loads and PLN voltage sources and generators carried out on miniature circuit breakers trip changes occurred which were still within the standard limits of SPLN 108: 1993. Then the results of testing of non-linear load such as a combination of incandescent, spotlight lamps, and fluorescent lamp ballast electronic, with currents flowing at 1.5 x In on the MCB. In the MCB using the PLN voltage source get MCB 2A THD Current 71.45%, MCB 4A THD Current 46.64%, MCB 6A THD Current 34.71% while the MCB using Genset voltage source get MCB 2A THD Current 52.07%, MCB 4A THD Current 31.54%, MCB 6A THD Current 24.62%. From the tests that have been done in getting the results, the greater harmonic distortion (THD Current) can affect the working mechanism of the MCB which results in faster MCB termination time in terminating the circuit. ABSTRAK Tujuan dari penelitian ini adalah untuk mengetahui pengaruh distorsi harmonisa dengan beban harmonik terhadap kinerja trip miniature circuit breaker Tipe C Arus 2A, 4A, dan 6A Metode yang digunakan adalah metode deskriptif kuantitatif. Subjek penelitian yang akan diteliti adalah miniature circuit breaker Pada pengumpulan data, dilakukan pengambilan populasi beban harmonik dan melakukan pengujian dengan alat ukur Power Quality Analyzer dengan sumber tegangan PLN dan Genset, hasil pengujian sampel MCB yang didapat lalu dianalisis mengenai karakteristik trip yang mengacu pada SPLN 108:1993 dan IEEE Hasil penelitian menunjukkan bahwa dari pengujian karakteristik trip dengan menggunakan beban harmonik dan sumber tegangan PLN dan genset yang dilakukan pada miniature circuit breaker terjadi perubahan trip yang masih dalam batas standar SPLN 108:1993. Kemudian hasil pengujian terhadap beban non linear berupa lampu hemat energi, lampu spotlight, dan kombinasi lampu pijar dengan arus yang di alirkan sebesar 1.5 x In pada MCB. Pada MCB dengan menggunakan sumber tegangan PLN di dapatkan MCB 2A THD Arus 71.45%, MCB 4A THD Arus 46.64%, MCB 6A THD Arus 34.71% sedangkan Pada MCB dengan menggunakan sumber tegangan Genset di dapatkan MCB 2A THD Arus 52.07%, MCB 4A THD Arus 33.35%, MCB 6A THD Arus 24.62%. Dari pengujian yang telah dilakukan di dapatkan hasil semakin besar distorsi harmonik arus (THD Arus) maka dapat mempengaruhi mekanisme kerja pada MCB yang mengakibatkan waktu pemutusan MCB menjadi lebih cepat dalam melakukan pemutusan rangkaian.
SIMULASI ALIRAN DAYA PADA SISTEM TENAGA LISTRIK DI GARDU INDUK GANDUL PT. PLN (PERSERO) MENGGUNAKAN SOFTWARE MATLAB POWER SYSTEM ANALYSIS TOOLBOX (PSAT) 2.1.7 DENGAN METODE NEWTON RAPHSON Endiansyah Pradana; Rif’an Muhammad; Imam Arif Raharjo
Journal of Electrical Vocational Education and Technology Vol 5 No 1 (2020): Journal Of Electrical Vocational Education and Technology
Publisher : Fakultas Teknik Universitas Negeri Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21009/JEVET.0051.03

Abstract

ABSTRACT This study aims to determine the results of the simulation of the power flow transformer 4 10 buses in the Gandul Substation of PT. PLN (Persero) with MATLAB Power System Analysis Toolbox (PSAT) 2.1.7. To find out the results of a comparison of the simulation of the flow of power 4 transformer 10 buses in the Gandul substation PT. PLN (Persero) MATLAB PSAT 2.1.7 software with ETAP software 12.6.Data analysis technique used in this study is quantitative descriptive analysis method. Descriptive will only describe the state of a symptom that has been recorded and then processed according to its function. Descriptive statistics are statistics that have the task of organizing and analyzing numerical data, in order to provide a regular, concise and clear picture of a phenomenon, event or situation, so that certain understandings or meanings can be drawn.The results of research on power flow at the Gandul substation PT. PLN (Persero) uses MATLAB Power System Analysis Toolbox (PSAT) 2.1.7 simulation of power flow with MATLAB PSAT 2.1.7 software completed at Power Flow Completed 0.066 s with a number of 2 iterations, iteration 1 shows Maximum Convergency Error 0.0011257 and iteration 2 shows Maximum Convergency Error 1.2621e-06. While the result of the simulation software ETAP 12.6 the number of oterations completed in iteration 3.The results of power flow simulation software MATLAB PSAT 2.1.7 and ETAP 12.6 on Active Power (MW) have a fairly big error, which is 11.5%. The largest error value generated is 11.5%, namely the feeder Sheen and Niece. Then, the results of power flow simulation software MATLAB PSAT 2.1.7 and ETAP 12.6 on Reactive Power (MVar) have a fairly big error, which is 24.4%. The largest error value generated is 24.4%, which is found in Canggah feeders. And the results of power flow simulation software MATLAB PSAT 2.1.7 and ETAP 12.6 against voltage (kV) have a fairly small error. Almost every feeder has the same error from the Rainbow feeder to the niece.The conclusion in this study is the results of power flow simulation with MATLAB Power System Analysis Toolbox 2.1.7 show the value of Active Power of 15.1362 MW and Reactive Power of 10.0349 MVar. Meanwhile, the results of power flow simulation with ETAP 12.6 software show the value of Active Power of 15.3720 MW and Reactive Power of 10.3510 MVar. ABSTRAK Penelitian ini bertujuan Untuk mengetahui hasil dari simulasi aliran daya Trafo 4 10 bus di Gardu Induk Gandul PT. PLN (Persero) dengan software MATLAB Power System Analysis Toolbox (PSAT) 2.1.7. Untuk mengetahui hasil perbandingan simulasi aliran daya Trafo 4 10 bus di Gardu Induk Gandul PT. PLN (Persero) software MATLAB PSAT 2.1.7 dengan software ETAP 12.6. Teknik analisis data yang digunakan pada penelitian ini adalah metode analisis desktriptif kuantitatif. Deskriptif hanya akan mendeskripsikan keadaan suatu gejala yang telah direkam kemudian diolah sesuai dengan fungsinya. Statistik deskriptif adalah statistik yang mempunyai tugas mengorganisasi dan menganalisa data angka, agar dapat memberikan gambaran secara teratur, ringkas dan jelas, mengenai suatu gejala, peristiwa atau keadaan, sehingga dapat ditarik pengertian atau makna tertentu. Hasil penelitian aliran daya di gardu induk Gandul PT. PLN (Persero) menggunakan software MATLAB Power System Analysis Toolbox (PSAT) 2.1.7 simulasi aliran daya dengan software MATLAB PSAT 2.1.7 selesai pada Power Flow Completed 0.066 s dengan jumlah 2 iterasi, iterasi 1 menunjukkan Maximum Convergency Error 0.0011257 dan iterasi 2 menunjukkan Maximum Convergency Error 1.2621e-06. Sedangkan hasil simulasi software ETAP 12.6 jumlah iterasi selesai pada iterasi 3. Hasil simulasi aliran daya software MATLAB PSAT 2.1.7 dan ETAP 12.6 pada Daya Aktif (MW) mempunyai error yang cukup besar, yaitu 11.5%. Nilai error terbesar yang dihasilkan sebesar 11.5% yaitu pada penyulang Kemilau dan Keponakan. Lalu, hasil simulasi aliran daya software MATLAB PSAT 2.1.7 dan ETAP 12.6 pada Daya Reaktif (MVar) mempunyai error yang cukup besar, yaitu 24.4%. Nilai error terbesar yang dihasilkan sebesar 24.4%, yaitu terdapat pada penyulang Keponakan. Dan hasil simulasi aliran daya software MATLAB PSAT 2.1.7 dan ETAP 12.6 terhadap tegangan (kV) mempunyai error yang cukup kecil. Hampir setiap penyulang mempunyai error yang sama dari penyulang Pelangi hingga Keponakan. Kesimpulan dalam penelitian ini yaitu Hasil simulasi aliran daya dengan software MATLAB Power System Analysis Toolbox 2.1.7 menunjukkan nilai Daya Aktif sebesar 15.1362 MW dan Daya Reaktif sebesar 10.0349 MVar. Sedangkan, hasil simulasi aliran daya dengan software ETAP 12.6 menunjukkan nilai Daya Aktif sebesar 15.3720 MW dan Daya Reaktif sebesar 10.3510 MVar.
HUBUNGAN ANTARA SISTEM PENDINGIN UTAMA DENGAN NILAI EFISIENSI PLTP KAMOJANG UNIT 4 Keumala Hayati Azizah; Suyitno; Imam Arif Raharjo
Journal of Electrical Vocational Education and Technology Vol 6 No 1 (2021): Journal Of Electrical Vocational Education and Technology
Publisher : Fakultas Teknik Universitas Negeri Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21009/JEVET.0061.02

Abstract

Tujuan dari penelitian ini adalah untuk mengetahui seberapa erat hubungan antara pengaruh kinerja sistem pendingin utama dengan nilai efisiensi PLTP Kamojang Unit 4. Penelitian ini dilaksanakan di Pembangkit Listrik Tenaga Panas Bumi, PT. Pertamina Geothermal Energi Kamojang yang dimulai pada 03 November 2016 hingga 02 Desember 2016. Jenis penelitian ini adalah penelitian asosiatif dengan pendekatan kuantitatif. Hasil dari penelitian ini menunjukkan bahwa dalam waktu satu bulan pengukuran pada tanggal 03 November 2016 sampai tanggal 02 Desember 2016, dapat dilihat rata – rata kinerja Sistem Pendingin Utama yaitu Cooling Tower tertinggi yaitu tertinggi pada tanggal 27 November 2016 dengan nilai sebesar 72282239 J/s dan rata – rata kinerja sistem pendingin utama yaitu Cooling Tower terendah pada tanggal 01 Desember 2016 dengan nilai sebesar 66976733 J/s. Dengan rata – rata kinerja sistem pendingin utama selama satu bulan sebesar 68574481 J/s. Sedangkan rata – rata nilai efisiensi PLTP Kamojang Unit 4 tertinggi berada pada tanggal 01 Desember 2016 dengan nilai sebesar 22% dan rata – rata nilai efisiensi PLTP Kamojang Unit 4 terendah pada tanggal 27 November 2016 dengan nilai sebesar 16%. Dengan rata – rata nilai efisiensi PLTP Kamojang Unit 4 selama satu bulan sebesar 20%. Dari nilai rata – rata tersebut dapat dibuat diagram scatter untuk menunjukkan seberapa besar koefisien korelasinya. Dalam diagram scatter garis trendline diagram miring ke kanan bawah membentuk garis lurus dan sempit. Nilai R2 antara sistem pendingin utama dengan nilai efisiensi PLTP Kamojang Unit 4 adalah R2 = 0,9459, artinya hubungan antara rendah dan tingginya kinerja sistem pendingin terhadap nilai efisiensi PLTP adalah sebesar 94,59%. Dengan mengakarkan nilai R2 akan di dapat nilai koefisien korelasi, yang hasilnya R = 0,9725. Nilai koefisien korelasi R = 0,9725 termasuk pada kategori hubungan sangat kuat antara kinerja sistem pendingin utama terhadap nilai efisiensi PLTP Kamojang unit 4. Berdasarkan hasil tersebut terdapat hubungan yang sangat kuat antara kinerja sistem pendingin utama dengan nilai PLTP Kamojang Unit 4.
RANCANG BANGUN ALAT MONITORING PANEL SURYA BERBASIS ARDUINO UNO DENGAN PROGRAM PLX-DAQ Muhamad Rizky Kurniawan; Muhammad Rif’an; Imam Arif Raharjo
Journal of Electrical Vocational Education and Technology Vol 6 No 1 (2021): Journal Of Electrical Vocational Education and Technology
Publisher : Fakultas Teknik Universitas Negeri Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21009/JEVET.0061.05

Abstract

Penelitian ini bertujuan untuk membuat alat monitoring panel surya berbasis arduino uno untuk menghasilkan data arus, tegangan, dan intensitas radiasi yang akan digunakan memonitoring pembangkit listrik tenaga surya secara otomatis. Penelitian ini dilaksanakan di gedung pusat inovasi LIPI, Cibinong, Bogor, Jawa Barat pada bulan Desember 2016 – Januari 2017. Metode yang digunakan adalah metode eksperimen yaitu menghubungkan sensor dengan arduino uno, kemudian dihubungkan ke komputer server dengan menggunakan sinyal radio frekuensi menggunakan XBee. Langkah yang dilakukan adalah membuat program alat, lalu membuat hardware alat, membuat interface dengan PLX-DQA. Pengujian dilakukan pada hardware dan software. Dari hasil pengujian, alat ukur multimeter pengujian beban led 3 watt dengan rata – rata tegangan 6,27 V dan arus 0,022 A. Pengujian alat monitoring dengan rata- rata 6,61 V dan arus memiliki rata- rata 0,027 A. Dengan eror untuk ampere adalah 18 % dan eror untuk voltase adalah 5,1 %.