Claim Missing Document
Check
Articles

Found 6 Documents
Search

Pengaturan Debit Air Berdasarkan Volume Air Dalam Tangki Berbasis Imperalis Competitive Algorithm (ICA) Markhaban Siswanto; Mohammad Hasib Al Isbilly; Asnun Parwanti; Machrus Ali
Jurnal Intake : Jurnal Penelitian Ilmu Teknik dan Terapan Vol. 8 No. 2 (2017): Oktober 2017
Publisher : FT- UNDAR

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.48056/jintake.v8i2.29

Abstract

An aquatic industry needs a good fluid flow measurement control system. Determination of the quantity of water is reduced because the volume of water in the holding tank varies. The effort to overcome this problem is made a system of performance regulation of water flow based on the volume of tanks with PID controls based on Imperalis Competitive Algorithm (ICA). This system uses ICA as a PID controller controller on a mini computer, flow sensor as a water speed detector, electric ball valve as an actuator. The working principle of this tool is to stabilize the output water speed per minute at a predetermined set point. This study compares 3 models; without control, PID control, PID Ziegler Nichols control, and PID controlled ICA controls. The simulation results in the study showed that the best control design in the study was the PID-ICA with the smallest overshot water level of 0.0154 pu, the smallest undershot water level of 0.0134 pu, the smallest overshot flow of 0.0102 pu, and the smallest undershot of 0.0097 pu.
Pembuatan Nuget Dari Ampas Tahu Untuk Meningkatkan Ekonomi Masyarakat Desa Sumbermulyo Kecamatan Jogoroto Kabupaten Jombang Prayogi Ferdiansyah; Rubaid Dasururi; Asnun Parwanti; Muhid Maksum; Kadaryono Kadaryono; Enis Muazzahroh
Jurnal Pengabdian Masyarakat Universitas Darul Ulum Vol 1 No 2 (2022): DIMAS-UNDAR
Publisher : Universitas Darul Ulum

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32492/dimas.v1i2.63

Abstract

Limbah industri tahu saat ini pada UKM belum dikelola secara bijak dan baik, limbah padat dan cairnya dibuang ke lingkungan, seperti selokan dan sungai. Untuk itu perlu ditingkatkan upaya untuk memanfaatkan limbah hasil aktivitas masyarakat. Upaya pemanfaatan limbah ini selain merupakan upaya pengembangan sumber daya manusia yang dapat membuka peluang usaha baru.Banyak jenis limbah dapat dimanfaatkan kembali melalui daur ulang ataupun dikonversikan ke produk lain yang berguna, salah satunya limbah dari industri tahu. Limbah tersebut biasanya masih mengandung serat, karbohidrat, protein, lemak, asam organik, dan mineral dan pada dasarnya dapat mengalami perubahan secara biologis sehingga dapat dikonversikan ke produk lain seperti energi, pangan, pakan, pupuk organis dan lain-lain.Konsep pemanfaatan limbah sebagai upaya untuk membangun usaha kecil dan menengah (UKM), pertamatama harus diketahui sifat kimia dan fisikanya, sehingga dapat diperkirakan berbagai produk yang mungkin dihasilkan. Kemudian produk yang dipilih dipertimbangkan dengan pasar dan teknoekonominya. Sebagai contoh ampas tahu yang memiliki sifat kimiawi yang didominasi oleh protein sehingga dapat diolah menjadi pangan seperti nugget yang berfungsi sebagai sumber protein dan dapat meningkatkan ekonomi masyarakat.
Pengendalian Level Air Modern dengan Algoritma Semut ACO-PID untuk Kontrol Presisi Asnun Parwanti; Machrus Ali; Izzatul Umami; Rukslin
Jurnal FORTECH Vol. 4 No. 2 (2023): Jurnal FORTECH
Publisher : FORTEI (Forum Pendidikan Tinggi Teknik Elektro Indonesia)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56795/fortech.v4i2.4207

Abstract

Fluid flow measurement and control are fundamental requirements in various industrial processes, particularly for maintaining stable water volumes in storage tanks. Water level control systems typically employ Proportional–Integral–Derivative (PID) controllers. A primary challenge with PID controllers lies in determining the Kp, Ki, and Kd constants; manual tuning or trial-and-error approaches often result in slow, oscillatory, and suboptimal responses. This study proposes automated PID parameter tuning using Ant Colony Optimization (ACO), an artificial intelligence method that mimics the behavior of ant colonies in finding the shortest path via pheromone trails. The tuning objective function utilizes the Integral of Time-multiplied Absolute Error (ITAE) to minimize overshoot and settling time. The performance of the proposed PID-ACO method was compared against four scenarios—an uncontrolled system, conventional PID, Fuzzy Logic Controller (FLC), and Fuzzy-PID—using MATLAB/Simulink simulations. Simulation results demonstrate that PID-ACO delivers the best performance, achieving the lowest water level overshoot (0.5039 pu) and undershoot (0.5187 pu). Regarding output flow, the method achieved the lowest overshoot (0.0016 pu) and undershoot (0.0009 pu), as well as the fastest settling time. Thus, ACO-based PID tuning is proven to significantly enhance the stability and accuracy of water level control compared to the benchmark methods.
Performasi Metode Kecerdasan Buatan (FA, PSO, ACO, GWO, dan OPA) Untuk Penalaan PID Pada Pengendalian Level Air Izzatul Umami; Asnun Parwanti; Machrus Ali; Dafit Soni Setiawan
Jurnal FORTECH Vol. 5 No. 2 (2024): Jurnal FORTECH
Publisher : FORTEI (Forum Pendidikan Tinggi Teknik Elektro Indonesia)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56795/fortech.v5i2.5208

Abstract

Water level control is a critical problem in various industrial processes, such as water treatment, power generation, chemical industry, and irrigation. Although proportional–integral–derivative (PID) controllers are widely used due to their simple structure and ease of implementation, determining the parameters Kp, Ki, and Kd remains challenging for systems with nonlinear dynamics and actuator limitations. This study presents a comparative evaluation of five population-based metaheuristic algorithms—Firefly Algorithm (FA), Particle Swarm Optimization (PSO), Ant Colony Optimization (ACO), Grey Wolf Optimizer (GWO), and Orca Predation Algorithm (OPA)—for automatic tuning of PID parameters in a second-order water tank model with actuator saturation of ±5 pu. The objective function employed is the Integral of Time-multiplied Absolute Error (ITAE) with an overshoot penalty. The comparison was conducted under identical conditions, including population size, number of iterations, parameter search ranges, initial conditions, and objective function. Simulation results demonstrate that ACO-PID achieves the lowest ITAE value of 0.2352 and the fastest settling time of 1.32 s. FA-PID, GWO-PID, and OPA-PID yield closely comparable performance, whereas PSO-PID produces zero overshoot at the expense of the highest ITAE value of 0.2668 and the longest settling time of 1.66 s. The execution times of all five algorithms are relatively similar, ranging from 4.84 to 5.16 s. These findings indicate that ACO is the most suitable method for the plant configuration and objective function examined in this study; however, the performance differences among ACO, FA, GWO, and OPA are relatively small and cannot be considered statistically significant without multi-run testing and statistical analysis.
Pengendalian Level Air Modern dengan Algoritma Semut ACO-PID untuk Kontrol Presisi Asnun Parwanti; Machrus Ali; Izzatul Umami; Rukslin
Jurnal FORTECH Vol. 4 No. 2 (2023): Jurnal FORTECH
Publisher : FORTEI (Forum Pendidikan Tinggi Teknik Elektro Indonesia)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56795/fortech.v4i2.4207

Abstract

Fluid flow measurement and control are fundamental requirements in various industrial processes, particularly for maintaining stable water volumes in storage tanks. Water level control systems typically employ Proportional–Integral–Derivative (PID) controllers. A primary challenge with PID controllers lies in determining the Kp, Ki, and Kd constants; manual tuning or trial-and-error approaches often result in slow, oscillatory, and suboptimal responses. This study proposes automated PID parameter tuning using Ant Colony Optimization (ACO), an artificial intelligence method that mimics the behavior of ant colonies in finding the shortest path via pheromone trails. The tuning objective function utilizes the Integral of Time-multiplied Absolute Error (ITAE) to minimize overshoot and settling time. The performance of the proposed PID-ACO method was compared against four scenarios—an uncontrolled system, conventional PID, Fuzzy Logic Controller (FLC), and Fuzzy-PID—using MATLAB/Simulink simulations. Simulation results demonstrate that PID-ACO delivers the best performance, achieving the lowest water level overshoot (0.5039 pu) and undershoot (0.5187 pu). Regarding output flow, the method achieved the lowest overshoot (0.0016 pu) and undershoot (0.0009 pu), as well as the fastest settling time. Thus, ACO-based PID tuning is proven to significantly enhance the stability and accuracy of water level control compared to the benchmark methods.
Performasi Metode Kecerdasan Buatan (FA, PSO, ACO, GWO, dan OPA) Untuk Penalaan PID Pada Pengendalian Level Air Izzatul Umami; Asnun Parwanti; Machrus Ali; Dafit Soni Setiawan
Jurnal FORTECH Vol. 5 No. 2 (2024): Jurnal FORTECH
Publisher : FORTEI (Forum Pendidikan Tinggi Teknik Elektro Indonesia)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56795/fortech.v5i2.5208

Abstract

Water level control is a critical problem in various industrial processes, such as water treatment, power generation, chemical industry, and irrigation. Although proportional–integral–derivative (PID) controllers are widely used due to their simple structure and ease of implementation, determining the parameters Kp, Ki, and Kd remains challenging for systems with nonlinear dynamics and actuator limitations. This study presents a comparative evaluation of five population-based metaheuristic algorithms—Firefly Algorithm (FA), Particle Swarm Optimization (PSO), Ant Colony Optimization (ACO), Grey Wolf Optimizer (GWO), and Orca Predation Algorithm (OPA)—for automatic tuning of PID parameters in a second-order water tank model with actuator saturation of ±5 pu. The objective function employed is the Integral of Time-multiplied Absolute Error (ITAE) with an overshoot penalty. The comparison was conducted under identical conditions, including population size, number of iterations, parameter search ranges, initial conditions, and objective function. Simulation results demonstrate that ACO-PID achieves the lowest ITAE value of 0.2352 and the fastest settling time of 1.32 s. FA-PID, GWO-PID, and OPA-PID yield closely comparable performance, whereas PSO-PID produces zero overshoot at the expense of the highest ITAE value of 0.2668 and the longest settling time of 1.66 s. The execution times of all five algorithms are relatively similar, ranging from 4.84 to 5.16 s. These findings indicate that ACO is the most suitable method for the plant configuration and objective function examined in this study; however, the performance differences among ACO, FA, GWO, and OPA are relatively small and cannot be considered statistically significant without multi-run testing and statistical analysis.