Journal : Jurnal Teknik Sipil

PERENCANAAN TEKNIS JARINGAN PERPIPAAN AIR BERSIH DENGAN SISTEM PENGALIRAN POMPA DI DESA SUSULAKU A KECAMATAN INSANA KABUPATEN TIMOR TENGAH UTARA Tuames, Gaspar Y. K.; Bunganaen, Wilhelmus; Utomo, Sudiyo
Jurnal Teknik Sipil Vol 4, No 1 (2015): Jurnal Teknik Sipil
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1669.925 KB)

Abstract

Desa Susulaku A memiliki sumber air yang cukup memadai tetapi yang menjadi kendala adalah sumber mata air berada di bawah pemukiman warga sehingga diperlukan pompa untuk menaikan air ke pemukiman warga.Penelitian ini bertujuan untuk merencanakan jaringan perpipaan air bersih dengan sistem pengaliran pompa di Desa Susulaku A.Metode yang digunakan dalam perhitungan proyeksi jumlah penduduk menggunakan Metode Aritmatik, menghitung pertambahan jumlah fasilitas, serta perhitungan proyeksi kebutuhan air. Selanjutnya melakukan analisis hidrolis pada pompa dan jaringan pipa serta hal yang diperhatikan dalam sistem operasional dan pemeliharaan. Hasil proyeksi jumlah penduduk Dusun II Desa Susulaku A tahun 2023 adalah 631 jiwa. Besar kebutuhan air pada tahun rencana adalah 0,47 ltr/dtk. Debit Mata Air Oetak adalah 1,727 ltr/dtk. Jenis pipa yang digunakan adalah jenis pipa GIP,berdiameter pipa 2 inchi dan 2,5 inchi. Volume bak penampung mata air (BPMA) 14 m3, volume bak penampung (BP) 12 m3 dan volume hidran umum (HU) 10 m3. Spesifikasi pompa 65 x 50X2 - 5 15 dengan waktu beroperasi pagi hari 1 jam dan sore hari 1 jam. Teknis operasional menyangkut hal-hal teknik yakni rincian kebutuhan operasional dan pemeliharaan, pelaku dan keterampilan yang dibutuhkan. Organisasi pengelola terdiri dari struktur organisasi dan tata peran serta perkiraan biaya operasional dan pemeliharaan perbulan adalah Rp 2.347.300, sehingga tarif yang dikenakan adalah Rp 25.000/KK/bulan. The Susulaku A Village have adequate water source but the are some consentrain that is the water source is located under the citizen housing so to bossting up the water to citizen housing, the pump watering system is needed. The purpose of this research is to design the clean water pipeline network with pump watering system at Susulaku A village. The used method to calculating the projected of population amount is aritmatic method, calculating the increase amount of facility and also calculating the projected of the water requirement.. The next step is doing the Hydraulic Analyze of pump and pipeline network by considered the operation and maintenance system. The result of projected population amount in Area II of Susulaku A village in 2023 is 631. The number of water requirement based on the year plan is 0,47 liter/sec. Oetak spring debit is 1,727 liter/sec. The type of pipe in this research is GIP pipe with diameter 2,00 inch and diameter 2,50 inch. The spring basin volume (BPMA) is 14 m³, Basin volume (BP) is 12 m³, and volume public hydrants (HU) is 10 m³. The pump specification is 65 x 50X2 – 5 15 with operation time 1 hour in the morning and 1 hour in the afternoon. Operational technic are concern maintenance and operational requirement details, treatment and competent worker is also needed. The management organization consists of structural organization and the role arrangement and also projected of operational and maintenance finance is Rp.2.347.300, so the contribution charged is Rp.25.000/household/month.
IDENTIFIKASI KUAT ACUAN TERHADAP JENIS KAYU YANG DIPERDAGANGKAN DI KOTA KUPANG BERDASARKAN SNI 7973:2013 Hunggurami, Elia; Utomo, Sudiyo; Messakh, Beddy Y.
Jurnal Teknik Sipil Vol 5, No 2 (2016): JURNAL TEKNIK SIPIL
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (106.097 KB)

Abstract

According to results of the test, quality code of each woods is: Timber = E14, Spinach = E14, Red Teak = E12, Candlenut wood = E10 and Cassowary = E15.The compressive strength perpendicular to the wood fibers: Timber= 23,00 MPa, Spinach = 31,00 MPa, Teak Red = 9,67 MPa, Candlenut= 8.67 MPa and cassowary= 21,67 MPa. The compressive strength parallel to the wood fibers: Timber = 70,33 MPa, Spinach = 79,33 MPa, Teak Red = 36,00 MPa, Candlenut= 26,00 MPa and cassowary = 50,00 MPa. Value bending strength of wood: Timber= 132,06 MPa, Spinach= 174,66 MPa, Teak Red= 59,64 MPa, Candlenut= 51,12 MPa and cassowary= 110,76 MPa. The percentage value of compressive strength test comparison between the wood fibers parallel investigation against SNI 7973: 2013: Timber= 164,01%, Spinach= 197.80%, Teak Red= 59.57%, Candlenut= 57.00% and Cassowary= 73,61%. Value percentage ratio of compressive strength test perpendicular to the wood fibers are examined against SNI 7973: 2013: Timber= 365.29%, Spinach= 527,12%, Teak Red= 131,54%, Candlenut= 143,64% and Cassowary= 479,20%. Percentage value comparison test between the flexural strength of the wood studied the SNI 7973: 2013: Timber= 312,64%, Spinach = 445,74%, Teak Red = 121,51%, Candlenut= 154,76% and Cassowary= 215.99%.
KELAYAKAN PASIR KALI MAS SEBAGAI AGREGAT HALUS PADA CAMPURAN BETON DAN MORTAR Resi, Aristofel R.; Hunggurami, Elia; Utomo, Sudiyo
Jurnal Teknik Sipil Vol 6, No 2 (2017): Jurnal Teknik Sipil
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1167.849 KB)

Abstract

Perkembangan daerah yang sejalan dengan perkembangan pembangunanterus meningkat sehingga kebutuhan material untuk pembangunan juga meningkat. Pembangunan di daerah – daerah berkembang masih menggunakan beton sebagai bahan konstruksi. Kebutuhan akan material beton sangatlah tinggi sehingga perlu adanya eksplorasi tempat baru.Masyarakat pada kecamatan Fatuleu Barat mengambil pasir pada Kali Mas untuk dijadikan sebagai material pembangunan konstruksi beton karena jarak pengambilan pasir lebih dekat dibandingkan dengan pengambilan dari quarry Takari. Tujuan penelitian untuk mengetahui kuat tekan beton dan mortar menggunakan pasir Kali Mas dibandingkan dengan pasir Takari. Benda uji beton yang dipakai berbentuk silinder 15 x 30 cm dengan mutu rencana 15 MPa dan 25 MPa dengan durasi curing 7, 14dan 28 hari. Sedangkan mortar berbentuk kubus berukuran 5 x 5 x 5 cm dengan komposisi campuran 1Pcc : 2Psr, 1Pcc : 4Psr, 1Pcc : 6Psr dan 1Pcc : 8Psr dengan durasi curing 3,7, 21 dan 28 hari. Berdasarkan hasil pengujian kuat tekan beton dan mortar yang menggunakan pasir Kali Mas lebih besar dari pada menggunakan pasir Takari. The growth of regions which is in step with the establishment progress continuous to increase so material requirements for construction has also been increasing. Development in developing areas still uses concrete as a construction material. The need for concrete material is so high same needing for exploration of new places. Communities in Fatuleu Barat Subdistrict took sand from Kali Mas serve as construction concrete material because the distance was closer than taking from quarry Takari. The purpose of this research is to find out compressive strength of concrete and mortar using Kali Mas sand compared with Takari sand. The object that used for the manufacture of concrete cylinder measuring 15 x 30 cm with a quality planned is 15 MPa and 25 MPa with 7, 14 and 28 days of curing duration. While the object which is used to make manufacture of mortar cube measuring 5 x 5 x 5 cm with a mixed composition 1 pcc: 2 psr, 1 pcc: 4 psr, 1 pcc: 6 psr and 1 pcc: 8 psr with duration of curing 3, 7, 21 and 28 days. Based on concrete strength test result with mortar that use Kali Mas sand greater than using Takari sand.
PERENCANAAN INSTALASI PENGOLAHAN AIR LIMBAH RUMAH TANGGA KOMUNAL PADA DAERAH PESISIR DI KELURAHAN METINA KECAMATAN LOBALAIN KABUPATEN ROTE-NDAO Fanggi, Marthini S.; Utomo, Sudiyo; Udiana, I Made
Jurnal Teknik Sipil Vol 4, No 2 (2015)
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (99.84 KB)

Abstract

Instalasi Pengolahan Air Limbah (IPAL) Komunal merupakan salah satu solusi bagi lingkungan perkotaan atau pesisir yang padat. Penelitian ini dilakukan dengan metode kuisoner dan teknik analisis yang digunakan adalah analisis deskriptif kuantitatif yang memberikan gambaran dengan jelas dan benar makna dari indikator- indikator yang ada. Sampel penelitian adalah masyarakat di RT 07, 08, 09 /RW 03, dan RT 10, 11/ RW 04 Kelurahan Metina, Kecamatan Lobalain, Kabupaten Rote Ndao, berjumlah 46 KK dari 262 KK. Skor rerata ideal 37,25 sampai 39,5 digolongkan pada kategori cukup baik karena modus berada pada kategori dua dengan frekuensi sebanyak 18 kali atau 39,13 %.. Desain bangunan IPAL komunal dengan tahun rencana 20 tahun. Jumlah penduduk P(2034) adalah 1330 orang, kebutuhan air bersih yaitu 80 L/orang/hari. Debit rata-rata air limbah adalah 64 liter / hari/ orang, debit puncak adalah 115,2 liter/hari/orang. Kapasitas pengolahan adalah 153,216 m3/hari. Volume bak pemisah lemak/minyak 3,192 m3, volume bak ekualisasi 31,92 m3, volume bak pengendapan awal 19,152 m3, volume bak biofilter anaerob 34,47 m3,volume bak biofilter aerob 34,47 m3. Volume bak pengendap Akhir 19,15 m3. Diameter pipa dari kloset dan air limbah non tinja adalah 100 mm. Diameter pipa utama adalah 150 mm. Waste Water Treatment Plant (WWTP) Communal is one of the solutions for the urban environment or coastal solid. This study was conducted using questionnaires and analysis technique used is quantitative descriptive analysis gives a clear and true picture of the significance of the existing indicators. Samples were people in RT 07,08,09 /RW 03 and RT 10,11 /RW 04 Metina Village, District Lobalain, Rote Ndao, totaling 46 families of 262 families. Ideal mean score 37,25 to 39,5 is classified in the category quite well because of the mode are in two categories with a frequency of 18 times or 39,13% . The building design communal WWTP with the 20 year plan. The total population is 1330 people, needs clean water that is 80 L/person/day. Average discharge of waste water is 64 liter/day/person, the peak discharge was 115,2 liters/day/person. Processing capacity is 153.216 m3/day. Volume tub fat separator 3,192 m3, the volume of 31,92 m3 equalization basin, the volume of 19,152 m3 initial deposition bath, bath volume 34,47 m3 biofilter anaerobic, aerobic biofilter volume of 34,47 m3. Final settling basin volume of 19,15 m3. Diameter pipe from the toilet and waste water non stool is 100 mm. The main pipe diameter is 150 mm.
PERBANDINGAN NILAI EKIVALENSI KENDARAAN RINGAN TIME HEADWAY METHOD DAN PKJI 2014 PADA SIMPANG APILL KUPANG Bolla, Margareth E.; Chandra, Kavin J.; Utomo, Sudiyo; Rizal, Andi H.
Jurnal Teknik Sipil Vol 9, No 1 (2020)
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (228.66 KB)

Abstract

Arus lalu lintas dinyatakan dalam satuan kendaraan ringan dengan konversi yang disebut  nilai ekivalensi kendaraan ringan (ekr) yang terdapat dalam PKJI 2014. Nilai ekr untuk saat ini ditetapkan dari penelitian secara empiris yang dilaksanakan pada tahun 1991 sampai tahun 1996 sehingga nilai ekr tersebut tidak relevan dengan kondisi lalu lintas saat ini. Penelitian ini bertujuan untuk menganalisis nilai ekr pada simpang APILL di simpang 4 El Tari dan Kirab kota Kupang dengan menggunakan metode time headway untuk membandingkan  nilai tersebut dengan ketetapan pada PKJI 2014, serta menganalisis kinerja simpang. Hasil analisis menunjukkan perbedaan antara nilai ekr hasil analisis dengan PKJI 2014, dimana dengan metode time headway didapat ekr untuk Kendaraan Berat (HV) 6,61 dan untuk Sepeda Motor (MC) 0,59. Analisis  kinerja pada simpang Kirab menghasilkan nilai derajat kejenuhan rata-rata simpang 1,21, panjang antrian maksimum 164,54 meter pada pendekat Frans Seda 2 (FS2) dan tundaan rata-rata simpang 215,52 det/skr dengan tingkat layanan pada level F yaitu kategori tingkat pelayanan terburuk, sedangkan untuk simpang El Tari menghasilkan nilai derajat kejenuhan rata-rata simpang 1,21, panjang antrian maksimum 214,19 meter pada pendekat El Tari (ET) dan tundaan rata-rata simpang 229,44 det/skr dengan tingkat layan pada level F yaitu kategori tingkat pelayanan terburuk.Traffic flow is expressed in units of light vehicles with a conversion value called the passenger car unit (pcu) value that can be found in IHCG 2014. The current pcu value is determined from empirical research conducted from 1991 to 1996 so that it is not relevance with current traffic conditions. This research with the aim to analyzing the pcu value at the signalised intersection at the 4 intersection  of El Tari and Kirab in Kupang city by using the time headway method to compare these values with the provisions in the IHCG 2014, also analyze intersection performance. The results shows that differences in value of the analysis with IHCG 2014, where the value for Heavy Vehicles (HV) is 6.61 and for Motorcycles (MC) is 0.59. The performance analysis at the Kirab intersection produces the average degree of saturation value at the intersection is 1.21, the maximum queue length is 164.54 meters in the Frans Seda 2 approach (FS2) and t.e average delay intersection is 215.52 sec/pcu atF service level which is the worst service level category, while for the El Tari’s intersection produce the average degree of saturation value at the intersection is 1.21, the maximum queue length is 214.19 meters in the El Tari approach (ET) and the average delay of intersections is 229.44 sec/pcu at F service level which is the worst service level category.