Claim Missing Document
Check
Articles

IMPROVING THE EFFICIENCY AND ADEQUACY OF URBAN ROAD-PASSENGER TRANSPORT Pah, Jusuf J.S.
Jurnal Teknik Sipil Vol 1, No 4 (2012)
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (52.363 KB)

Abstract

This study offered ways to improve the efficiency and adequacy of urban public transport in Kupang, taking as the background the viewpoint that urban transport should concern not only middle and high income people but urban poor as well. It focused on three principle modes of public transport in the city, two of which are formal: city bus, and bemo, and the remaining one is informal/paratransit locally known as ‘ojek’. It took urban transport strategic review published recently by the World Bank as the quarry form which solutions for efficiency and adequacy the city’s passenger-transport were drawn and developed as to suit specific demand of the same. It concluded that to improve the service of public transport in the city, ‘competition-for the-market’ should be introduced into the market of its urban transport form of for-the-market competition recommended are route-concession. It stressed also however that prior to it state-owned motor companies should be privatized, and their capacity to engage in an open competition should be made better. As for bemo, service-contract should be introduced into the relation between the owner and the operators, whereas paratransit should be recognized and regarded as part of the whole urban public transportation system
EVALUASI BATASAN TINGGI MAKSIMUM BANGUNAN TINGKAT TINGGI BERATURAN UNTUK PENERAPAN METODE STATIK EKUIVALEN Pah, Jusuf J. S.; Udiana, I Made; Matarohi, Deddy I.
Jurnal Teknik Sipil Vol 3, No 2 (2014): Jurnal Teknik Sipil
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (523.141 KB)

Abstract

Dalam penelitian ini dilakukan analisis atas model komputer spesimen struktur bangunan gedung tingkat tinggi menggunakan program komputer: ETABS 2013. Spesimen terbagi ke dalam dua kelompok, spesimen pada kelompok pertama menggunakan sistem rangka (spesimen 9F36) sedangkan pada kelompok kedua menggunakan sistim dinding geser (9SW36). Tinggi awal setiap spesimen adalah 36 m (9 tingkat). Atas setiap spesimen dilandakan 4 akselelogram gempa yaitu El-Centro, Kobe, Chi-Chi Taiwan dan Jepang; dan asesmen untuk mengetahui moda pergoyangan meraka dilakukan. Jika moda pergoyangan yang ditunjukan adalah moda 1 maka satu tingkat (4 m) ditambahkan kepada spesiemen dan akselelogram gempa-gempa dilandakan atasnya dengan cara yang sama seperti sebelumnya, sampai spesiemen menunjukkan pergoyangan dalam moda yang lebih tinggi daripada moda 1. Hasil penelitian ini menunjukkan bahwa spesimen dengan sistem rangka beralih dari bergoyang dalam mode 1 ke mode 2 pada ketinggian 9 lantai (36 m) sedangkan spesimen dengan sistem dinding geser beralih dari bergoyang dalam mode 1 ke mode 2 pada ketinggian 15 lantai (60 m). Terbukti bahwa metoda statik ekivalen dapat diterapkan pada struktur bangunan tingkat tinggi dengan sistem dinding geser yang ketinggiannya melebhi 10 tingkat (40 m) sampai dengan ketinggian 14 tingkat (54 m). Dengan demikian kedalam butir 4.2.1 SNI 1726-2002 perlu integrasikan pembedaan sistem penahan lateral.
PENGARUH VARIASI PERHITUNGAN TEGANGAN DAN REGANGAN KOLOM BETON BERTULANG TERHADAP DAKTILITAS PENAMPANG TAKTERKEKANG Simatupang, Partogi H.; Siallagan, Gisella D.; Pah, Jusuf J. S.
Jurnal Teknik Sipil Vol 7, No 1 (2018): Jurnal Teknik Sipil
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (262.065 KB)

Abstract

Salah satu parameter penting dalam  perencanaan suatu kolom adalah daktilitas.  Nilai daktilitas suatu kolom dapat ditentukan dari kurva hubungan antara momen dan kurvatur. Nilai momen dan kurvatur didapat dari perhitungan tegangan dan regangan beton.Tujuan penelitian ini adalah untuk mengetahui pengaruh variasi tegangan dan regangan kolom beton bertulang terhadap daktilitas penampang tak terkekang. Dalam analisis ini hubungan tegangan dan regangan menggunakan 4 metode yaitu Kent and Park, Popovics, Thorenfeldt dan Hognestad yang kemudian dilakukan analisis momen dan kurvatur secara manual dari hubungan tegangan dan regangan. Selain menghitung secara manual juga digunakan program bantuResponse 2000. Output Response 2000 digunakan sebagai pembanding dengan cara perhitungan manual. Hasil analisis secara manual maupun menggunakan Response 2000 menunjukkan luas tulangan longitudinal dan mutu tulangan longitudinalyang meningkat dapat menurunkan nilai daktilitas kolom sedangkan mutu beton yang meningkat maka daktilitas juga meningkat. Selain itu, konfigurasi tulangan longitudinal juga dapat mempengaruhi nilai daktilitas suatu kolom dengan nilai daktilitas paling kecil terdapat pada sampel UC3-01.One of the important parameter in a column planning is ductility. Ductility of a column can determined from relation curve between moment and curvature.Moment and curvature value is obtained from the calculation of concrete stress and strain.This research aims is to know the effect of stress and strain variation of reinforced concrete column on unconfined section ductility.In this research, stress and strain relation use 4 methods such as Kent and Park, Popovics, Thorenfeldt and Hognestad and then moment-curvature analysis is done manually by Ms.Excel 2013 from stress-strain relation. Besides counting manually also used the Response 2000 program. Output of Response 2000 is used as a comparison by manual calculation. The results of manual analysis or using Response 2000 indicates that an increase in the area of longitudinal reinforcement and the steel yield strength can decreases the ductility while an increase in the concrete strength increases the ductility. In addition, the configuration of longitudinal reinforcement also affects the ductility of a column with the smallest ductility value in the UC3-01.
KOMPOSIT BETON-PROFIL LIP CHANNEL UNTUK MENCEGAH TEKUK LATERAL-TORSIONAL Loe, Ridwan Rinaldo; Pah, Jusuf J. S.; Wahyuningsih, Tri Mardiyati
Jurnal Teknik Sipil Vol 1, No 3 (2012)
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (121.808 KB)

Abstract

ABSTRACTLip channels profile usually failed before reaching its maximum loaddue to torsional. To avoid this problem, usually lateral support isprovided to the profile. One of the solution is by filling the profile withconcrete material (composite). The purpose of this research is to knowthe bending strength ratio of lip channels profile to lip channels-concretecomposite. The specimens in this research is lip channelsC85x40x8x0.90, C85x40x8x0.65, C75x40x10x0.75, C75x40x10x0.65and two pieces of composite beams of 85x40x1100 mm with two piecesof composite beams 75x40x1100 mm. Beside the bending strength testas the main test, additional test should be runned by concretecompression test using 12 pieces of 150x150x150 cube and 12 pieces oflip channels. Based on this research, it is found that the bending strengthof the lip channels (P-1) and composite beam (K-1) are 262.06 MPa and366.35 MPa each. The result means that there is 1.40 (39.80%)increasing in bending strength. For P-2 the bending strength is 268.64MPa while K-2 is 453.60 MPa or increased 1.69 (68.85%). For P-3bending strength is 180.90 MPa while K-3 is 364.75 MPa, increased 2.02(101.63%). For P-4 the bending strength is 207.59 MPa while K-4 is430.05 MPa, increased 2.07( 107.16%). ABSTRAKUmumnya profil lip channel mengalami kegagalan sebelum mencapaibeban maksimum karena lebih dahulu mengalami puntir. Untukmencegah hal tersebut, diberi sokongan lateral pada profil. Alternatifyang ingin diteliti yaitu dengan cara mengisi material beton (komposit).Tujuan dilakukannya penelitian ini adalah untuk mengetahui besarnyaperbandingan kapasitas lentur profil lip channel dengan komposit betonprofillip channel. Benda uji dalam penelitian ini berupa profil lipchannel C85x40x8x0,90, C85x40x8x0,65, C75x40x10x0,75,C75x40x10x0,65 dan balok komposit dengan ukuran 85x40x1100 mmsebanyak 2 buah, serta 75x40x1100 mm sebanyak 2 buah. Disampingpenelitian utama yaitu pengujian kapasitas lentur profil lip channel danbalok komposit, dilakukan pengujian tambahan, diantaranya untukmengetahui mutu beton maka dilakukan pengujian kuat tekan betondengan benda uji kubus berukuran 150x150x150 mm sebanyak 12 buahdan pengujian kuat tarik profil lip channel untuk mengetahui besar kuattarik profil sebanyak 12 sampel. Berdasarkan hasil penelitian diperolehkapasitas lentur pada baja profil yang tidak dicor beton (P-1) dan yangdicor beton (K-1) masing-masing sebesar 4000 N dan 12000 N. Dengandemikian terjadi peningkatan 3,00 kali atau 200,00%. Untuk P-2kapasitas lenturnya 3000 N sedangkan K-2 13000 N atau mengalamipeningkatan sebesar 4,33 kali (333,33%). Untuk P-3 kapasitas lenturnya2000 N sedangkan K-3 9000 N sehingga mengalami peningkatan 4,50kali (350,00%). Untuk P-4 nilai kapasitas lenturnya 2000 N sedangkanK-4 10000 N sehingga mengalami peningkatan 5,00 kali (400,00%).
KUAT GESER KOMPOSIT BAJA – BETON DENGAN VARIASI BENTUK PENGHUBUNG GESER DITINJAU DARI UJI GESER MURNI Lahamukang, Krisantus M.; Pah, Jusuf J. S.; Messah, Yunita A.
Jurnal Teknik Sipil Vol 3, No 1 (2014): JURNAL TEKNIK SIPIL
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (754.288 KB)

Abstract

Composite plan assumes that steel and concrete collaborating in bearing the working burden; this will result in a more economical profile design. Besides, the composite structure also has several advantages, such as stronger and more rigid than the non-composite structure. To ensure coherency between the concrete and steel beams, it must be installed a shear connector device on the steel that connected with concrete. The purpose of this study was to determine which shear connector’s strength is stronger; especially the Stud type shear connector with steel quality of 305,17 MPa and the L type shear connector with steel quality of 406,10 MPa. Specimens used were steel-concrete composite with a length of 200 mm, width 164 mm and height of 280 mm with the quality of two types of concrete quality which are 17 MPa and 20 MPa, the composite specimens using two types of shear connector, which are Stud type shear connector and L type shear connector. Concrete mixture planning refers to SK SNI T-15-1990-03. Result of this study shows that stud type shear connector form strongly resists the shear of a steel composite as much as 26,50 KN for concrete quality of 17 MPa and 33,83 KN for concrete quality of 20 MPa.
PENGGUNAAN BLOK PERSEGI TERMODIFIKASI DAN TRAPESIUM DALAM PERENCANAAN BETON MUTU TINGGI DAN SANGAT TINGGI Pah, Jusuf J.S.; Ratu Edo, Carysa R.; Sir, Tri M. W.
Jurnal Teknik Sipil Vol 4, No 1 (2015): Jurnal Teknik Sipil
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (555.996 KB)

Abstract

Tujuan dari penelitian ini adalah untuk mendapatkan tatacara perencanaan beton mutu tinggi dan sangat tinggi dengan menggunakan blok pendekatan persegi yang termodifikasi dan blok trapesium. Penelitian dimulai dengan studi literatur dan perhitungan luasan diagram interaksi tegangan regangan beton. Setelah itu dilakukan ekuivalensi antara luasan diagram interaksi tegangan regangan dan luasan blok pendekatan, kemudian diperoleh koefisien-koefisien penyesuaian. Langkah selanjutnya adalah menurunkan rumus yang mengandung koefisien penyesuaian untuk mendapatkan rasio tulangan perlu dan langkah yang terakhir adalah menyusun tata cara perencanaan beton bertulang mutu tinggi dan sangat tinggi. Mutu beton yang ditinjau dalam penelitian ini adalah beton dengan mutu 15 – 120 MPa. Untuk pendekatan persegi termodifikasi diperoleh koefisien penyesuaian β1 berkisar antara 0.68 sampai 0.98, dengan 0.68 merupakan nilai β1 untuk beton 120 MPa sedangkan 0.98 untuk beton 15 MPa. Nilai β1 tersebut adalah nilai yang aman karena telah sesuai dengan syarat nilai β1 menurut SNI 03-2847-2002 yaitu β1 ≥ 0.65.Untuk pendekatan trapesium diperoleh nilai koefisien α untuk penyesuaian luasan berkisar antara 0.16 sampai 0.63, sedangkan untuk koefisien penyesuaian titik berat (γ) berkisar antara 0.0061 sampai 0.0222. The purpose of the research is to obtained a design procedure for flexure design of high strength and ultra high strength concrete; using modified rectangular block and trapezoidal block approaches. Analytical and design equations were formulated for each of the approaches, then by equating area of the block with that of actual stress-strain diagram, and internal moment of the force of the block to that of the actual stress-strain diagram, characeristic coefficients of each aproach were determined and adjusted. The procedure was done on high and ultra-high strength concrete (fc’ in the range of 15 to 120 MPa. The value of β1 ¬–coefficient for modified rectangular block approach was found to be in the range of 0.68 to 0.98, where 0.68 is β1 for 120 MPa and 0.98 for 15 MPa. These values are safe as it complies with the value required for it by SNI 03-2847-2002 namely that β1 ¬¬must be greater than 0.65. For the trapezoidal block approach there are two coefficients. They are α, coefficient for the area adjustment and γ, coefficient for the adjustment of center of mass. The research yielded that α is in the range of 0.16 to 0.63 and γ is in the range of 0.0061 to 0.0222. Design procedure was then prepared using each of the approach based on their respective characteristic coefficients.
PENGARUH DINDING PENGISI PADA LANTAI DASAR BANGUNAN TINGKAT TINGGI TERHADAP TERJADINYA MEKANISME SOFT STORY Tosari, Dessy S.; Hunggurami, Elia; Pah, Jusuf J. S.
Jurnal Teknik Sipil Vol 5, No 1 (2016): JURNAL TEKNIK SIPIL
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (303.841 KB)

Abstract

Dalam penelitian ini dilakukan analisis pushover dengan Program ETABS 2013 terhadap spesimen dengan sistem portal dengan tinggi 8 tingkat atau 29,5 meter. Spesimen yang pertama adalah spesimen tanpa dinding pengisi pada lantai dasar, selanjutnya spesimen-spesimen yang lain adalah spesimen dengan penambahan 20%, 40%, 60%, 80%,dan 100% dinding pengisi pada lantai dasar. Keenam spesimen akan dianalisis dengan analisis pushover. Pada Spesimen pertama dianalisis dengan pushover untuk melihat mekanisme keruntuhan soft story yang terjadi, selanjutnya spesimen-spesimen dengan penambahan 20%, 40%, 60%, 80%, dan 100% dinding pengisi pada lantai dasar dianilisis dengan analisis pushover. Hasil dari analisis tersebut ternyata struktur masih mengalami mekanisme soft story, namun perilaku struktur dengan dinding pengisi pada lantai dasar berbeda dibandingkan dengan struktur tanpa dinding pengisi pada lantai dasar dilihat dari gaya geser dasar dan kekakuan struktur.
PENGARUH UKURAN DIAMETER PIPA OUTLET FOAM GENERATOR TERHADAP KUAT TEKAN DAN SERAPAN AIR BATA RINGAN JENIS CLC Bella, Rosmiyati A.; Sinlae, Astryana M.; Pah, Jusuf J. S.
Jurnal Teknik Sipil Vol 5, No 2 (2016): JURNAL TEKNIK SIPIL
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (298.746 KB)

Abstract

The power of Cellular Lightweight Concrete is influenced by the size of its pores. If the Lightweight Concrete’s pore is larger, then the compressive strength is smaller and the uptake of water produced is greater. This is caused by the using of the outlet pipe diameter that is greater cause cavities in the foam produced even greater. That foam occupy cubes of concrete’ space and generate pores that are large on the Lightweight Concrete, causing its compressive strength are small and water’s absorption is large if it is compared to the diameter of the outlet pipe is smaller. The test results in the laboratory is the compressive strength of Cellular Lightweight Concrete in 14 days amounted to 2.148 MPa, 2.074 MPa, 1.926 MPa and 1.852 MPa on the variation of ½ inch, 1 inch, 1 ½ inch and 2 inches diameter. In 28 days, it amounted to 2,667 MPa, 2,593 MPa, 2,444 MPa, dan 2,296 MPa with same diameters. In 42 days, it amounted to 2,815 MPa, 2,667 MPa, 2, 519 MPa, dan 2,444 MPa on diameter of 0,5 inch, 1 inch, 1,5 inch, and 2 inches. In 56 days, it amounted to 2,889 MPa, 2,741 MPa, 2,593 MPa, and 2,519 MPa with same diameters. At the age of 56 days, the average value of water absorption of the CLC with outlet foam generator of diameter of 0.5 inches amounted to 13.554%. Whereas on 1-inch increase to 15.268%. The size of 1.5 inches increased to 17.163% and the size of 2 ins by 19.463%.
PENGGUNAAN PASIR WEOL SEBAGAI BAHAN CAMPURAN MORTAR DAN BETON STRUKTURAL Kadimas, Irenius O.R; Pah, Jusuf J.S.; Bella, Rosmiyati A.
Jurnal Teknik Sipil Vol 6, No 1 (2017)
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (387.599 KB)

Abstract

Concrete is formed from a mixture of water, cement, sand and coarse aggregate. The quality of sand affects the quality of the concrete. Weol sand is aggregate in the subdistrict Ruteng, Manggarai district, which is used by people for mortar and non-structural concrete. This is because the location of which is closer than the other sand. This study aims to determine the compressive strength of mortar and concrete using Weol sand.The method of implementation refers to the SNI 03-2834-2000 (BSN 2000) about Manufacturing Process Plan Mixture for Normal Concrete and SNI 03-6825-2002 (BSN 2002b) about The Test Method of Compressive Strength Portland Cement Mortar. The mortar cube has size 5x5x5 with composition 1PC: 2Psr, 1PC: 4Psr, 1PC: 6Psr and 1PC: 8Psr. The diameter and high of cylindrical concrete is 15 cms and 30 cms. Mortar compressive strength testing performed at 3 days, 7 days, 14 days and 28 days while the concrete at 7 days, 14 days and 28 days.The test results show that the compressive strength of mortar using Weol sand for each composition and the compressive strength of concrete using Weol sand for each quality plan is larger than mortar and concrete using Takari sand.
STUDI KELAYAKAN FINANSIAL INVESTASI PERUMAHAN UME MALINAN PERMAI KABUPATEN KUPANG Messah, Yunita A.; Pah, Jusuf J. S.; Putri, Ria A.
Jurnal Teknik Sipil Vol 4, No 2 (2015)
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (235.591 KB)

Abstract

Untuk memenuhi kebutuhan perumahandosen dan pegawai, pihak Undana bekerja sama dengan PT. Spison Brajo selaku developer membangun sebuah kawasan perumahan yang diberi nama Perumahan Ume Malinan Permai. Mengingat dana yang dibutuhkan cukup besar, perlu dilakukan penyusunan studi kelayakan untuk menghindari resiko kerugian di masa yang akan datang.Tugas akhir ini bertujuan untuk mengetahui kelayakan proyek perumahan Ume Malinan Permai terhadap aspek finansial. Untuk mengetahui ketersediaan jumlah tempat tinggal digunakan perhitungan peluang pasar dan untuk mengetahui kelayakan dari segi finansial digunakan perhitungan analisa uji kelayakan dengan parameter investasi yaitu NPV, IRR dan PP.Setelah diadakan analisis, diperoleh kesimpulan bahwa peluang pasar pembangunan perumahan Ume Malinan Permai sangat menjanjikan karena besarnya peluang pasar (market potencial) di Kupang yaitu 58489 unit pada tahun 2018.Dari aspek ekonomi dengan biaya investasi sebesar Rp. 9,536,722,200.00 dan perhitungan uji kelayakan investasi dalam jangka waktu 5 tahun menggunakan 4 asumsi penjualan berbeda disimpulkan bahwa asumsi keempat lebih besar dari 3 asumsi lainnya dengan nilai NPV sebesar Rp. 5,548,503,421,IRRsebesar 25.2112% dan PP selama 3 tahun. Perumahan Ume Malinan Permai yang dilakukan oleh PT. Spison Brajo dikatakan layak (feasible) direalisasikan dari aspek finansial. To fulfill the need of lecturer and staff’shousing, Undana in cooperation with PT. Spison Brajo as the developer built a residential district named Ume Malinan Permai Housing. Because of the huge funds required, feasibility studies need to be done to avoid the risk of losses in the future.This final assesment aims to determine the feasibility of Ume Malinan Permai housing project on the financial aspects. To know the availability of the number of dwelling, calculation of market opportunities is used while to know the feasibility in financial terms, due diligence analysis calculation is used with the investment parameters, namely NPV, IRR and PP.After been analysed, it is concluded that the market opportunities of Ume Malinan Permai housing is very promising because of the large market opportunities (market potencial) in Kupang are 58489 units in 2018.From the economic aspect with the investment cost of Rp. 9,536,722,200.00 and the calculation of investment feasibility test within a period of 5 years using 4 different sales assumptions it has been concluded that the fourth assumption is greater than 3 other assumptions withNPV of Rp. 5,548,503,421,IRR of 25.2112% and PP for 3 years. Ume Malinan Permai housing conducted by PT. Spison Brajo is feasible to be realized on financial aspects.