Claim Missing Document
Check
Articles

Found 3 Documents
Search

Perancangan Ulang Alat Perontok Biji Jagung dengan Metode Quality Function Deployment Mahmud Basuki; Selvia Aprilyanti; Azhari Azhari; Erwin Erwin
Jurnal INTECH Teknik Industri Universitas Serang Raya Vol. 6 No. 1 (2020)
Publisher : Universitas Serang Raya

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1044.19 KB) | DOI: 10.30656/intech.v6i1.2196

Abstract

Tujuan penelitian ini adalah merancang alat pemipil biji jagung menggunakan pendekatan Quality Function Deployment (QFD). Langkah awal penelitian ini adalah melakukan identifikasi kebutuhan konsumen yang bertujuan mengetahui dan menjawab kebutuhan konsumen. Hasil identifikasi kebutuhan konsumen tersebut, digunakan untuk membangun House of Quality (HOQ). Berdasarkan House of Quality (HOQ), persentase bobot tertinggi yaitu ergonomis dengan nilai 100 %, dimensi ukuran sesuai dengan nilai 93 %, desain bentuk sesuai dengan nilai 87 %. Dengan prinsip ergonomis, dimensi ukuran sesuai dengan rata-rata postur tubuh masyarakat Indonesia, serta desain bentuk yang sesuai kebutuhan seperti mengatasi supaya jagung tidak berhamburan. Rancangan alat didesain bentuk corong, sesuai kebutuhan konsumen yaitu alat mudah, nyaman, aman untuk digunakan. Penelitian ini menghasilkan rancangan alat berukuran dengan tinggi alat 85 cm, panjang 50 cm, dan lebar 30 cm.
Review Ulang Area Percetakan Koran PT Sumsel Media Grafika dengan Pendekatan Activity Relationship Chart Mahmud Basuki; M Yus Al-Amin; Faizah Suryani; Selvia Aprilyanti; Irnanda Pratiwi
Jurnal Optimalisasi Vol 8, No 2 (2022): Oktober
Publisher : Universitas Teuku Umar

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35308/jopt.v8i2.5017

Abstract

Tata letak adalah suatu cara dalam mewujudkan pengaturan fasilitas supaya optimal yang bertujuan dalam meminimalkan biaya produksi dan meningkatkan produktivitas. Tata letak yang tidak tepat seperti jarak gudang ke mesin cetak yang terlalu jauh akan berdampak pada pemborosan waktu proses produksi. Penelitian ini bertujuan untuk mereview tata letak percetakaan koran PT Sumsel Media Grafika dengan pendekatan metode activity relationship chart (ARC), dimana di dalam ARC terdapat 2 tahap yaitu ARD dan AAD.  Hasil penelitian didapatkan hasil bahwa dari 10 departemen terdapat 4 departemen yang mengalami perubahan sehingga menjadi prioritas perbaikan, sehingga layout awal  yang semula menggunakan area 750 m2 menjadi 450 m2 jika menggunakan layout alternatif. Sehingga area sisa seluas 300 m2 dapat disewakan.
Analisis Daya Dukung Tiang Berdasarkan Hasil Pengujian Pembebanan Statik Dan Dinamik Pada Konstruksi Gedung Hariman Al-Faritzie; Bazar Asmawi; Selvia Aprilyanti; Untung Nopansyah. S
Jurnal Tekno Global Vol. 14 No. 02
Publisher : UNIVERSITAS INDO GLOBAL MANDIRI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36982/jtg.v14i02.6680

Abstract

ABSTRACT Vertical development in urban areas drives the need for reliable and efficient geotechnical engineering, especially bored pile foundations that are able to withstand building loads in soil conditions that are predominantly clay and sandy. This study aims to analyze the bearing capacity of bored pile foundations using the static loading method (SLT) interpreted by the Davisson, Mazurkiewicz, and Chin approaches, as well as the dynamic loading method (PDA) analyzed by Capwap software. Tests were conducted at two SLT points and two PDA points. The results of static testing on the BP 65 pile showed an ultimate bearing capacity of 306.4 tons (Davisson), 284.12 tons (Mazurkiewicz), and 260.42 tons (Chin). While on BP 120, the ultimate bearing capacity was obtained at 384.39 tons, 391.57 tons and 378.79 tons, respectively. The results of the PDA test analyzed through Capwap showed the ultimate bearing capacity values of 413.8 tons (BP 59) and 419.5 tons (BP 113). The results of the study indicate that the bearing capacity of the bored pile foundation has generally met the safe limit. Recommendations based on actual conditions and calculations with soil data and the results of foundation loading tests using a pile diameter of 60 cm with a depth of 18 meters are considered effective and in accordance with the design load. The results of static and dynamic method tests are able to produce an accurate evaluation of the bearing capacity of the foundation and reflect the realistic characteristics of the soil at the test location.  Keywords : Bearing Capacity, Bored Pile, CAPWAP, PDA Test.   ABSTRAK Pembangunan secara vertikal di kawasan perkotaan mendorong kebutuhan akan rekayasa geoteknik yang andal dan efisien, khususnya pondasi tiang bor yang mampu menahan beban bangunan pada kondisi tanah yang dominan berupa lempung dan berpasir. Penelitian ini bertujuan menganalisis kapasitas daya dukung pondasi tiang bor menggunakan metode pembebanan statik (SLT) yang diinterpretasikan dengan pendekatan Davisson, Mazurkiewicz, dan Chin, serta metode pembebanan dinamik (PDA) yang dianalisis dengan perangkat lunak Capwap. Pengujian dilakukan pada dua titik SLT dan dua titik PDA. Hasil pengujian statik pada tiang BP 65 menunjukkan daya dukung ultimit sebesar 306,4 ton (Davisson), 284,12 ton (Mazurkiewicz), dan 260,42 ton (Chin), Sedangkan pada BP 120, diperoleh daya dukung ultimit masing-masing sebesar 384,39 ton, 391,57 ton dan 378,79 ton. Hasil pengujian PDA dianalisis melalui Capwap menunjukkan nilai daya dukung ultimit sebesar 413,8 ton (BP 59) dan 419,5  ton (BP 113). Hasil penelitian menunjukkan bahwa kapasitas daya dukung pondasi tiang bor secara umum telah memenuhi batas aman. Rekomendasi berdasarkan kondisi aktual dan perhitungan dengan data tanah dan hasil pengujian pembebanan pondasi  penggunaan diameter tiang 60 cm dengan kedalaman 18 meter dinilai efektif dan sesuai dengan beban rencana. Hasil pengujian metode statik dan dinamik mampu menghasilkan evaluasi kapasitas daya dukung pondasi yang akurat serta mencerminkan karakteristik tanah secara realistik di lokasi pengujian.  Kata Kunci : CAPWAP, Daya Dukung, PDA Test, Tiang Bor.