Claim Missing Document
Check
Articles

Found 2 Documents
Search

OKSIDASI SORBITOL MENGGUNAKAN MOLEKUL OKSIGEN YANG DIAKTIFASI KATALIS Pd/-Al2O3 DALAM PELARUT AIR Andriayani -; Saur Lumban Raja
Jurnal Riset Kimia Vol. 1 No. 1 (2007): September
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25077/jrk.v1i1.31

Abstract

 ABSTRACT The sorbitol has been oxidized by molecular oxygen that activated by Pd/g-Al2O3 catalyst in water solvent at 70°C. The product was contained 1.3 g (26%) of the glucaric acid. The product was characterized by FT-IR and 1H-NMR spectrophotometer. The product oxidation was reacted with solution of sodium hydroxide methanol at 70°C during 5 hours produced sodium dicarboxylate in the form yellow gel about 0.3 g (30%). The product was characterized by FT-IR and 1H-NMR spectrophotometer. Keywords: sorbitol, oxidation, catalyst, Pd/g-Al2O3, oxygen molecular 
AIR QUALITY MONITORING OF KALABAHI-ALOR’S SEAPORT-EAST OF NUSA TENGGARA Rikson Siburian; Minsyahril Bukit; Herlince Sihotang; Saur Lumban Raja; Minto Supeno; Cristina Simanjuntak; Nurhaida Pasaribu; Sri Pratiwi Aritonang
ABDIMAS TALENTA: Jurnal Pengabdian Kepada Masyarakat Vol. 3 No. 2 (2018): ABDIMAS TALENTA: Jurnal Pengabdian Kepada Masyarakat
Publisher : Talenta Publisher

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (639.517 KB) | DOI: 10.32734/abdimastalenta.v3i2.2641

Abstract

Evaluation of environment of seaport is needed as well as our responsibility to nature sustainability. The Alor’s seaport belongs to Pelindo III. In order to know the air quality of Alor’s seaport, we did this study. Our aims are to know level quality of air at Alor’s seaport and compare to the government regulation. This study refers to Pararosaniline (SOx), Saltzman (NOx), Particle Calculation (dust) and decibel (noisy) methods. We used four locations, those are A-1 (Entrance gate of PELINDO (8013’09.12”S, 124031’07.21”E)); A-2 (In front of passengers terminal (8013’08.75”S, 124031’01.60”E)); A-3 (Exit gate Kalabahi’s seaport (8013’08.2”S, 124031’00.87”E)) and A-4 (In front of port of the people (8011’09.12”S, 124031’07.21”E)). Results show that the averages level of SOx, NOx and dust of A-1, A-2 and A-3 are 103.01, 104.65 and 107.47 (µg/Nm3), 37.87, 30.62, and 39.73 (µg/Nm3), 56.64, 47.47 and 50.72 (µg/Nm), respectively. On the other hand, the level of noisy of A-1, A-2, A-3 and A-4 are 68.76, 65.69, 65.20 and 73.60 (dBA), respectively. Base on all of data, we conclude that the air quality of Alor’s seaport is still appropriate according to government regulation (PP. No. 4, 1999).