Maun Budiyanto, Maun
DEPARTEMEN TEKNIK ELEKTRO DAN INFORMATIKA, Sekolah Vokasi Universitas Gadjah Mada

Published : 11 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 11 Documents
Search

MODE SWITCH SARON ELEKTRONIK BERBASIS ATMEGA328 Fajeri, Fadil; Budiyanto, Maun
IKRA-ITH INFORMATIKA : Jurnal Komputer dan Informatika Vol 4 No 1 (2020): IKRAITH-INFORMATIKA Vol 4 No 1 Bulan Maret 2020
Publisher : Fakultas Teknik Universitas Persada Indonesia YAI

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (823.493 KB)

Abstract

Gamelan sudah dipatenkan sebagai warisan budaya Indonesia oleh UNESCO sejak tahun 2014. Seiring dengan perkembangan teknologi informasi, maka perlu inovasi dengan digitalisasi instrumen gamelan. Hal ini melatarbelakangi ide untuk membuat saron elektronik. Dalam perancanganya elektronik saron tetap memperhatikan kearifal lokal sehingga bentuknyapun menyerupai saron konvensional, hanya saja dalam proses pembentukan suaranya melalui mekanisme elektronis. Pada perancangan saron elektronik ini digunakan tangga nada atau laras slendro. Laras slendro adalah sebuah tangga nada yang terdiri: 1 (ji), 2 (ro), 3 (lu), 5 (mo), 6 (nem) tetapi ada dua nada yang memiliki nada rendah dan tinggi (6&1) sehingga saron dengan pelog slendro memiliki titi laras 6 (nem rendah), 1 (ji rendah), 2 (ro), 3 (lu), 5(mo), 6 (nem tinggi), 1 (ji tinggi). Saron elektronik yang dirancang ini menggunakan sistem switch, dimana setiap wilahan ini berfungsi sebagai input sedangan tabuh yang sudah ditempeli alumunium foil sebagai netral/ground. Ketika tabuh menyetuh wilahan maka akan terdapat perubahan logika, perubahan ini kemudian di proses oleh mikrokontroler untuk men-trigger nada, kemudian nada tersebut dikuatkan dengan amplifer sehingga suara instrumen saron bisa terdengar dengan keras.
PENDETEKSI KEBAKARAN DENGAN MENGGUNAKAN SENSOR SUHU LM35D DAN SENSOR ASAP Ahmad Faishal; Maun Budiyanto
Seminar Nasional Informatika (SEMNASIF) Vol 1, No 2 (2010): Instrumentational And Robotic
Publisher : Jurusan Teknik Informatika

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Umumnya kebakaran diketahui apabila keadaan api sudah mulai membesar atau asap sudah mengepul keluar dari gedung. Penelitian ini bertujuan untuk membuat peralatan pendeteksi kebakaran dengan memanfaatkan sensor elektronis, sehingga kebakaran dapat dideteksi secara dini. Digunakan dua sensor elektronis, yaitu tiga buah sensor asap dan tiga buah sensor suhu LM35D. Sistem akan bekerja ketika terdapat suhu dan asap. Pengolahan data untuk operasi logika dan operasi aritmatika digunakan mikrokontroler. Keluaran dari peralatan ini, berupa suara sirine dan mengaktifkan pompa air.
Prototipe Pengaman Pintu Rumah Menggunakan Voice Recognition dengan EasyVR Berbasis Mikrokontroler Syaeful Ulum; Maun Budiyanto
Jurnal Listrik, Instrumentasi, dan Elektronika Terapan Vol 1, No 2 (2020)
Publisher : Departemen Teknik Elektro dan Informatika Sekolah Vokasi UGM

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22146/juliet.v1i2.60744

Abstract

The adventages of technology make every job easier, but this ease sometimes isn’t matched by safety factors. Security is vital to avoiding this technology being misused by uninvited people.This journal discusses the security of home doors with a microcontroller-based voice. The voice recognition process starts from the sound that propagates and then processes the corresponding easyvr sensor so that the easyvr sends a command to the relay to open the doorlock solenoid. From various tests obtained from voice recognition that can support the sound in the form of recordings, in speech recognition with an achievement level of 45 dB approved sound with an ideal pitch at 0-700 cm, it needs 75 dB sound amplifier with an ideal distance of 0-20 cm. For the percentage of success range with 30-40% different and the percentage of sound success is above 90%.Kemajuan teknologi membuat pekerjaan menjadi mudah, namun kemudahan tersebut tidak diimbangi dengan faktor keamanan. Keamanan menjadi hal yang vital untuk menghindari teknologi tersebut tidak disalahgunakan oleh orang yang tidak berwenang. Pada jurnal ini membahas pengaman pintu rumah dengan pengenalan suara berbasis mikrokontroler. Proses pengenalan suara dimulai dari suara yang merambat lalu diproses sensor easyvr jika sesuai sampling maka easyvr mengirimkan perintah kepada relay untuk membuka solenoid doorlock. Dari berbagai pengujian didapatkan bahwa pengenalan suara tidak dapat mengenali suara dalam bentuk rekaman, pada pengenalan suara dengan tingkat kebisingan 45 dB mengenali suara dengan ideal  pada jark 0-700 cm, kebisingan 75 dB mengenali suara dengan ideal pada jarak 0-20 cm. Tingkat persentase keberhasilan suara yang berbeda 30-40% dan persentase keberhasilan suara yang sama diatas 90%.
DESAIN DAN IMPLEMENTASI PROGRAMMABLE LOGIC CONTROLLER ZELIO SOFT2 PADA PROSES OTOMASI INDUSTRI PENGEPAKAN Budiyanto, Maun; Prisda Oetari Sihombing, Krystin
Jurnal Teknologi dan Vokasi Vol 1 No 1 (2023): Jurnal Teknologi dan Vokasi
Publisher : ITP Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21063/jtv.2023.1.1.63-67

Abstract

The industrial world optimizes time, labor and process efficiency in producing goods. The application of automation technology is expected to increase the amount of production quickly and precisely. One of the technologies used is Smart relay. In this study using the Zelio Soft2 PLC smart relay software which is used to design and simulate the ball packing automation process. There are two programming languages ​​provided by Zelio Soft2, namely ladder diagrams (LD) and function block diagrams (FBD). The ladder diagram is designed to simulate the ongoing process step by step, while the FBD shows the type and block diagram used in the process. The designed system utilizes push buttons (on/off), box sensors, tennis ball sensors and driving motors. The results showed that the program simulation worked as planned.
ANALISIS ARUS HUBUNG SINGKAT DI PT PLN NUSANTARA POWER UP GRESIK PADA MOTOR BOILER FEED PUMP Harista Rahman, Alvin; Budiyanto, Maun
Jurnal Teknologi dan Vokasi Vol 2 No 1 (2024): Jurnal Teknologi dan Vokasi
Publisher : ITP Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21063/jtv.2024.2.1.78-84

Abstract

Reliability is the main characteristic that must be maintained in power generation units in line with the increase in electricity consumption in Indonesia. If this reliability cannot be maintained, it will damage the generating equipment and disrupt the distribution of electricity supply to the loads. Failure in the reliability of the power generation unit can be caused by short circuit fault current conditions. In this study, an analysis was carried out regarding the condition of the short circuit current in the electricity network at the load of the 4A boiler feed pump (BFP) motor PT PLN Nusantara Power UP Gresik. Analysis was carried out to determine the maximum and minimum short circuit current conditions using ETAP 12.6 software. There are two bus bars that are used as simulation objects when experiencing disturbances, namely the 15 kV busbar and the 4.16 kV M/C switchgear busbar. The simulation results obtained are the maximum and minimum short circuit values. The maximum value is obtained from transient conditions in the form of a three-phase fault and one phase to ground. While the minimum value is obtained from the steady state condition in the form of an inter-phase fault current.    
ANALISIS RUGI-RUGI DAYA DAN JATUH TEGANGAN PADA SALURAN TRANSMISI 150 KV GARDU INDUK PANDEAN LAMPER-PUDAK PAYUNG Khoirunnisa, Ulfah; Bayu Murti, Budi; Budiyanto, Maun
Jurnal Teknologi dan Vokasi Vol 2 No 2 (2024): Jurnal Teknologi dan Vokasi
Publisher : ITP Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21063/jtv.2024.2.2.54-68

Abstract

The need for electrical energy now extends to remote areas. According to KESDM, the number of household and industrial customers in Central Java and DIY increased from 2020 to 2022. To maintain system balance and accommodate the increasing load, power distribution efficiency is required. At the transmission stage, electrical energy is transferred on a large scale from the power plant to the substation through a 150 kV SUTT. During the distribution of energy, power losses and voltage drops often occur, which are influenced by transmission distance, conductor cross-sectional area, conductor resistance, and load. To ensure that power losses and voltage drops remain below 5% according to SPLN No. 72 of 1987, it is necessary to evaluate whether the transmission load of the Pandean Lamper-Pudak Payung Substation is in accordance with the capabilities of the 1xACSR 240/40 conductor. The research method uses voltage and current data at peak load which is analyzed by manual calculation and ETAP 19.0.1 simulation. The results of the percentage comparison of manual calculation and simulation of power losses and voltage drops are between 0.5%-1%. The largest power loss occurred on January 15, 2024 amounting to 543 kW from manual calculation and 563.5 kW from simulation results. The percentage value of power losses reached 5.66%, which exceeded the SPLN limit. The highest voltage drop of 2.01% occurred on the same date. Based on this value, the Pandean Lamper-Pudak Payung Substation transmission line has reached its maximum load and it is necessary to increase transmission capacity by adding conductors.     
ANALISIS ARUS HUBUNG SINGKAT DI PT PLN NUSANTARA POWER UP GRESIK PADA MOTOR BOILER FEED PUMP Harista Rahman, Alvin; Budiyanto, Maun
Jurnal Teknologi dan Vokasi Vol 2 No 1 (2024): Jurnal Teknologi dan Vokasi
Publisher : ITP Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21063/jtv.2024.2.1.78-84

Abstract

Reliability is the main characteristic that must be maintained in power generation units in line with the increase in electricity consumption in Indonesia. If this reliability cannot be maintained, it will damage the generating equipment and disrupt the distribution of electricity supply to the loads. Failure in the reliability of the power generation unit can be caused by short circuit fault current conditions. In this study, an analysis was carried out regarding the condition of the short circuit current in the electricity network at the load of the 4A boiler feed pump (BFP) motor PT PLN Nusantara Power UP Gresik. Analysis was carried out to determine the maximum and minimum short circuit current conditions using ETAP 12.6 software. There are two bus bars that are used as simulation objects when experiencing disturbances, namely the 15 kV busbar and the 4.16 kV M/C switchgear busbar. The simulation results obtained are the maximum and minimum short circuit values. The maximum value is obtained from transient conditions in the form of a three-phase fault and one phase to ground. While the minimum value is obtained from the steady state condition in the form of an inter-phase fault current.    
ANALISIS RUGI-RUGI DAYA DAN JATUH TEGANGAN PADA SALURAN TRANSMISI 150 KV GARDU INDUK PANDEAN LAMPER-PUDAK PAYUNG Khoirunnisa, Ulfah; Bayu Murti, Budi; Budiyanto, Maun
Jurnal Teknologi dan Vokasi Vol 2 No 2 (2024): Jurnal Teknologi dan Vokasi
Publisher : ITP Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21063/jtv.2024.2.2.54-68

Abstract

The need for electrical energy now extends to remote areas. According to KESDM, the number of household and industrial customers in Central Java and DIY increased from 2020 to 2022. To maintain system balance and accommodate the increasing load, power distribution efficiency is required. At the transmission stage, electrical energy is transferred on a large scale from the power plant to the substation through a 150 kV SUTT. During the distribution of energy, power losses and voltage drops often occur, which are influenced by transmission distance, conductor cross-sectional area, conductor resistance, and load. To ensure that power losses and voltage drops remain below 5% according to SPLN No. 72 of 1987, it is necessary to evaluate whether the transmission load of the Pandean Lamper-Pudak Payung Substation is in accordance with the capabilities of the 1xACSR 240/40 conductor. The research method uses voltage and current data at peak load which is analyzed by manual calculation and ETAP 19.0.1 simulation. The results of the percentage comparison of manual calculation and simulation of power losses and voltage drops are between 0.5%-1%. The largest power loss occurred on January 15, 2024 amounting to 543 kW from manual calculation and 563.5 kW from simulation results. The percentage value of power losses reached 5.66%, which exceeded the SPLN limit. The highest voltage drop of 2.01% occurred on the same date. Based on this value, the Pandean Lamper-Pudak Payung Substation transmission line has reached its maximum load and it is necessary to increase transmission capacity by adding conductors.     
DESAIN DAN IMPLEMENTASI PROGRAMMABLE LOGIC CONTROLLER ZELIO SOFT2 PADA PROSES OTOMASI INDUSTRI PENGEPAKAN Budiyanto, Maun; Prisda Oetari Sihombing, Krystin
Jurnal Teknologi dan Vokasi Vol 1 No 1 (2023): Jurnal Teknologi dan Vokasi
Publisher : ITP Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21063/jtv.2023.1.1.63-67

Abstract

The industrial world optimizes time, labor and process efficiency in producing goods. The application of automation technology is expected to increase the amount of production quickly and precisely. One of the technologies used is Smart relay. In this study using the Zelio Soft2 PLC smart relay software which is used to design and simulate the ball packing automation process. There are two programming languages ​​provided by Zelio Soft2, namely ladder diagrams (LD) and function block diagrams (FBD). The ladder diagram is designed to simulate the ongoing process step by step, while the FBD shows the type and block diagram used in the process. The designed system utilizes push buttons (on/off), box sensors, tennis ball sensors and driving motors. The results showed that the program simulation worked as planned.
RANCANG BANGUN SISTEM OTOMASI PALLETIZING MENGGUNAKAN MODEL PEMROGRAMAN INDUSTRI BERORIENTASI OBYEK Izzulhaq, Adrian Isna; Budiyanto, Maun
Jurnal Teknologi dan Vokasi Vol 3 No 2 (2025): Jurnal Teknologi dan Vokasi
Publisher : ITP Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21063/jtv.2025.3.2.185-194

Abstract

The increasing demand for electrical energy in Indonesia encourages the availability of a reliable, efficient and stable power distribution system, especially in maintaining voltage quality during the transmission to distribution process. One of the main challenges in the distribution system is the occurrence of voltage drops which if not controlled can reduce energy efficiency and damage electrical equipment. In overcoming these problems, this research applies the Artificial Neural Network (ANN) method based on the backpropagation algorithm as an alternative approach in analyzing and predicting voltage drops in power distribution networks. Simulations were conducted using MATLAB R2024b software with input variables in the form of voltage, power factor, conductor length and diameter, cable type resistance, reactance, and load current. Meanwhile, the output variable analyzed is voltage drop. The simulation results show that the ANN model has a high predictive ability indicated by the Mean Square Error (MSE) value of 0.012743, Root Mean Square Error (RMSE) of 0.11289, Mean Absolute Error (MAE) of 0.033586, and Mean Absolute Percentage Error (MAPE) of 6.4292 %. This low error value indicates that the ANN is able to recognize complex patterns between input variables and provide adaptive responses to various variations in distribution system conditions so that the application of ANN using the backpropagation algorithm proves effective and efficient as a tool in supporting the technical decision-making process.