Penanggulangan Transformator Distribusi Berbeban Lebih Dengan Metode Sisip Trafo Pada Penyulang PW-02 PT PLN (Persero) ULP Subulussalam Kota Filia Berkat Nanda Lumbantobing; Hamdani
Jurnal Nasional Teknologi Komputer Vol 6 No 2 (2026): April 2026
Publisher : CV. Hawari

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.61306/jnastek.v6i2.423

Abstract

Distribution transformer is one of the most important components in the distribution of electric power from distribution substations to customers. Distribution transformers that experience loads exceeding 80% of the transformer capacity will affect the life of the distribution transformer and can also affect the level and quality of service to consumers and have the potential for disruption. Therefore, it is necessary to take action so that the percentage of distribution transformer loading does not exceed the transformer capacity by installing an Insert Transformer. At PT. PLN (Persero) ULP SUBULUSSALAM KOTA, there is a transformer that experiences overloading that occurs at the SKI072-00 Distribution Substation of 96.016% and after the Insert Transformer is installed, the loading at the SKI072-00 substation becomes 43.27%. This proves that the installation of an Insert Transformer is a fairly good method for overcoming overload disturbances at the SKI072-00 Substation, so that it can extend the life of the transformer, improve the quality of service to customers and reduce the potential for disturbances because the transformer loading below 80% can work well.
ANALISIS PENINGKATAN KINERJA JARINGAN DISTRIBUSI 20 KV DENGAN METODE THERMOVISI DI PT.PLN (PERSERO) ULP CALANG Ridho Zachroni Zaef; Hamdani; Pristisal Wibowo
Jurnal Nasional Teknologi Komputer Vol 6 No 4 (2026): Oktober 2026
Publisher : CV. Hawari

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.61306/jnastek.v6i4.575

Abstract

The increasing consumption of electrical energy from year to year indicates that electricity has become an essential requirement for both communities and businesses, serving as a primary support for daily activities and the improvement of welfare. This condition requires electricity service providers to deliver optimal services to customers. Service quality can be evaluated using the reliability performance indices of the 20 kV distribution system, namely the System Average Interruption Duration Index (SAIDI) and the System Average Interruption Frequency Index (SAIFI). To improve these reliability indices, PT PLN (Persero) Unit Layanan Pelanggan (ULP) Calang implements the Thermovision method as a preventive maintenance technique for detecting potential equipment failures. Following its implementation, an evaluation of SAIDI and SAIFI values is necessary to assess the effectiveness of the method. Therefore, this study aims to analyze the impact of the Thermovision method on improving the reliability performance of the distribution system at PT PLN (Persero) ULP Calang. The results are expected to contribute to enhancing service reliability and providing more optimal electricity services to customers.
Analisis Kondisi Minyak Isolasi Transformator Berdasarkan Hasil Pengujian Karakteristik Minyak pada IBT Gitet Arun UPT Banda Aceh Kamaruzzaman Kamaruzzaman; Pristisal Wibowo; Hamdani Hamdani
Action Research Literate Vol. 10 No. 10 (2026): Action Research Literate
Publisher : Ridwan Institute

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.46799/arl.v10i10.3130

Abstract

Minyak isolasi berperan penting dalam mempertahankan kemampuan dielektrik dan pendinginan transformator, sehingga perubahan karakteristiknya perlu dipantau untuk mendukung keandalan penyaluran listrik. Penelitian ini bertujuan menganalisis kondisi minyak isolasi pada IBT 2R, IBT 2S, dan IBT 2T di GITET Arun UPT Banda Aceh serta membandingkan kondisinya pada dua periode pengujian. Penelitian menggunakan pendekatan deskriptif kuantitatif melalui dokumentasi enam sampel minyak dari periode November 2024 dan Agustus 2025. Sepuluh parameter dianalisis, meliputi tegangan tembus, kadar air, angka asam, tegangan antarmuka, warna, sedimen, resistivitas DC, viskositas, titik nyala, dan faktor rugi dielektrik. Setiap parameter diklasifikasikan berdasarkan kriteria penilaian, diberikan skor, kemudian diintegrasikan menggunakan Indeks Kesesuaian Karakteristik Minyak (IKKM). Hasil menunjukkan bahwa seluruh unit memperoleh IKKM sebesar 100% pada November 2024. Pada Agustus 2025, nilai IBT 2S dan IBT 2T tetap 100%, sedangkan IBT 2R menurun menjadi 96,67% akibat sedimen sebesar 0,02% yang dikategorikan sedang. Tegangan tembus menurun masing-masing sebesar 5,15%, 5,21%, dan 2,95%, tetapi tetap berkategori baik. Temuan tersebut menunjukkan bahwa indeks agregat perlu diinterpretasikan bersama perubahan parameter individual untuk menentukan prioritas pemantauan. Disimpulkan bahwa minyak seluruh unit masih berkategori baik berdasarkan kriteria penelitian, dengan perhatian khusus terhadap perkembangan sedimen pada IBT 2R. Pemantauan berkala diperlukan untuk mendeteksi perubahan lanjutan dan mendukung keputusan pemeliharaan berbasis kondisi.