Analysis of the Effectiveness of Using Digital Filters in Electronic Stethoscopes Andi Fathkur Rohman; Muhammad Ridha Mak'ruf; Triwiyanto Triwiyanto; Lamidi Lamidi; Phuoc-Hai Huynh
Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 4 No 4 (2022): October
Publisher : Department of Electromedical Engineering, POLTEKKES KEMENKES SURABAYA and IKATEMI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jeeemi.v4i4.256

Abstract

The heart sound produced in some cases of the disease shows a certain pattern. The purpose of this study was to design an electronic stethoscope for cardiac auscultation with the following display. The contribution in this study is being able to show certain patterns that can be diagnosed in the sound signal. So that the pattern can be known when there is a heart disease disorder, an electronic stethoscope will be made for auscultation of the next display, making it easier for users to diagnose heart disease. The heart sound is obtained from the mechanical activity of the heart which is tapped by a condenser mic. The heart sound will be held in a pre-amp circuit, then the filters used are High Pass Filters and Low Pass Filters with an interrupted frequency of 20-95 Hz. The output of the filter circuit will enter the booster circuit. Then it will be processed by the microcontroller. In processing the data that will be displayed on Nextion and Speaker, the author uses Arduino Mega. Based on the test, it can be seen that the digital filter has a slight error rate because it removes the most noise, while in the analog filter there is still a lot of noise. The results of the research that has been done can be implemented using a system that really supports the needs.
Design And Development Of Spo2, Bpm, And Body Temperature For Monitoring Patient Conditions In Iot-Based Special Isolation Rooms Dyah Purwitosari; Bambang Guruh Irianto; Triwiyanto Triwiyanto; Phuoc-Hai Huynh
Jurnal Teknokes Vol 16 No 2 (2023): June
Publisher : Jurusan Teknik Elektromedik, POLTEKKES KEMENKES Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/teknokes.v16i2.462

Abstract

The use of batteries as the main power source in portable equipment systems has several drawbacks, including the percentage of battery power that must be monitored so that the system is always active. Analysis of battery power efficiency is needed to determine the resistance of portable systems. This study makes a portable system for monitoring the condition of patients with infectious diseases in a special isolation room that can measure heart rate, body temperature, and oxygen saturation. The design of this device uses a 2200mAH battery as a power source on the IC TTGO ESP32 to manage data and display measurement results, the MAX30102 sensor to measure oxygen saturation and heart rate, and the MCP9808 sensor to measure body temperature. The design of this device has been tested on respondents aged 25-40 years by placing the sensor on the fingertip then the measurement results are compared with a standard device that has been calibrated. The measurement results show that the device is feasible to use because the measurement error value is ±5%. Testing the efficiency of battery power in normal mode and save mode. In normal mode, the current used in the device is 154.9 mA, while the save mode by not activating the LCD TTGO ESP32 requires a current of 126.7 mA. The results of the analysis show that using the battery in normal mode can activate the device for up to ±14 hours and in save mode for ±17 hours. This designed method is useful for measuring power efficiency in different device modes and the user knows the battery charging time at regular intervals.