Claim Missing Document
Check
Articles

Found 8 Documents
Search
Journal : Progressive Physics Journal

Hubungan tingkat intensitas bunyi dengan penurunan daya dengar pekerja Asmar Adhan Ramadhan; Pratiwi Sri Wardani; Devina Rayzy Perwitasari Sutaji Putri
Progressive Physics Journal Vol 2 No 2 (2021): Progressive Physics Journal
Publisher : Program Studi Fisika, Jurusan Fisika, FMIPA, Universitas Mulawarman

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1310.526 KB) | DOI: 10.30872/ppj.v2i2.781

Abstract

Abstract Noise is unwanted sound that can cause health problems and environmental comfort at a certain level and time. Noise Induced Hearing Loss (NHL) is a type of sensorineural hearing loss caused by exposure to sufficient/loud noise over a long period of time. This study was conducted to determine the effect of noise on the hearing of workers working in the Ground Handling area of ​​Samarinda airport, to determine the noise level received by workers in the Airport Ground Handling Area, and to know the importance of using PPE on the hearing of workers while doing work. The noise measurement method is measuring at predetermined points using a Sound Level Meter. Then, it was continued by measuring the hearing level of workers in a soundproof room alternately using audiometry, then a correlation test was carried out to determine the relationship between the two variables, namely noise and the hearing level of workers. Based on the results of the study, it is known from the results of the average hearing that has been correlated with total noise exposure in the work area, it can be seen that the hearing level of workers is decreasing over time, this is due to the amount of noise exposure received by workers during work activities.
Analisis Getaran Whole Body pada Supir Angkutan Umum di Samarinda Puspa Syadariah; Devina Rayzy Perwitasari Sutaji Putri; Pratiwi Sri Wardani; Mislan Mislan; Adrianus Inu Natalisanto
Progressive Physics Journal Vol 3 No 2 (2022): Progressive Physics Journal
Publisher : Program Studi Fisika, Jurusan Fisika, FMIPA, Universitas Mulawarman

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (391.81 KB) | DOI: 10.30872/ppj.v3i2.915

Abstract

Whole body vibration is vibration that propagates throughout the worker's body from vibration sources in the form of machines, vehicles, and so on. In this paper it is reported the results of research to determine the total value of vibration acceleration on several drivers of the public transport in Samarinda and to analyze the comfort level of the drivers receiving the vibration on their bodies. The components of the vibration acceleration were measured by using a vibration meter type of Svantex 106. The comfort level of the driver in receiving the vibration was assosiated with the scale of comfortable level set by the Ministry of Manpower of the Republic of Indonesia by decree number PER.13/MEN/X/2011. The research found that the average of the total value of vibration acceleration received by the drivers in A, B, and C transportations were 0.3877 m/s2 , 0.7056 m/s2 dan 0.6596 m/s2 , respectively. In Samarinda the drivers in B and C transportations were more uncomfortable to receive the whole body vibration than the drivers in C transportation.
Analisis Treatment Planning System dengan Menggunakan Teknik Box dan Teknik Antero Posterior-Postero Anterior pada Kasus Kanker Serviks Yasinta Erikania Daniartie; Pratiwi Sri Wardani; Devina Rayzy Perwitasari Sutaji Putri; Robert Janssen Stevenly; Suryaningsih Suryaningsih
Progressive Physics Journal Vol 3 No 1 (2022): Progressive Physics Journal
Publisher : Program Studi Fisika, Jurusan Fisika, FMIPA, Universitas Mulawarman

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (632.08 KB) | DOI: 10.30872/ppj.v3i1.873

Abstract

Cervical cancer is cancer that grows in the cells on the cervix. Cervical cancer can be treated using radiotherapy. The purpose of this study was to determine the ratio of the dose received by the target volume and Organ at Risk (OAR) as well as the isodose curve using 4 directions of radiation field (gantry angle: 0°, 90°, 180° and 270°) and 2 directions of radiation field (gantry angle: 0° and 180°). The data processing step in this research was to do radiation planning (planning) by using 4 directions of radiation field (gantry angle: 0°, 90°, 180° and 270°) and 2 directions of radiation field (gantry angle: 0° and 180°). Then a comparative analysis of the dose value received by the target volume and Organ at Risk (OAR) was carried out. A comparative analysis of the isodose curve was performed by using each of the techniques. The results obtained from this study are the target volume has minimal dose using the box technique compared to the antero posterior-postero anterior technique. For Organ at Risk, namely bladder and rectum, the dose was minimal by using the box technique compared to using the anteroposteriorpostero anterior technique. Meanwhile, the right and left femoral heads received higher doses using the box technique than the antero-posterior-postero anterior technique. And for the isodose curve planning results using the box technique shows a more even distribution of the dose distribution to the entire target volume compared to the antero posterior-postero anterior technique.
Penilaian Tingkat Risiko Postur Kerja Menggunakan Metode REBA dan Biomekanika Pada Aktivitas Mengangkat Beban Jordan, Aldi Rizki; Wardani, Pratiwi Sri; Subagiada, Kadek; Putri, Devina Rayzy Perwitasari Sutaji; Natalisanto, Adrianus Inu
Progressive Physics Journal Vol 4 No 1 (2023): Progressive Physics Journal
Publisher : Program Studi Fisika, Jurusan Fisika, FMIPA, Universitas Mulawarman

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30872/ppj.v4i1.1021

Abstract

The activity of lifting weights has many risks that can lead to complaints and work accidents such as mistakes in lifting excessive loads, overly bent postures, and other complaints that result in uncomfortable working conditions. This research was conducted to determine the risk level of work posture using the REBA method and biomechanics in lifting weights with different lifting variables. The research were took documentation data, angle and distance measurements by using the Kinovea application, and the data analyzed by using the REBA Assessment Worksheet and biomechanical equations. Based on the results obtained, the activity of lifting burdens on workers from the aspect of the REBA method mostly has a high level of risk category and only 1 worker has a moderate level of risk category. Meanwhile, from the biomechanics aspect, most of them have a risk level in the careful category, 1 worker has a risk level in the safe category, and 1 worker who has lifted a load of 50 kg has a risk level in the dangerous category.
Pengujian Karakteristik Alat Ukur Radiasi Dose Calibrator Menggunakan Sumber Teknesium-99m di Instalasi Kedokteran Nuklir Rumah Sakit Abdoel Wahab Sjahranie Samarinda Mutmainna, Fahira Mutya; Wardani, Pratiwi Sri; Putri, Erlinda Ratnasari; Zurma, Retno
Progressive Physics Journal Vol. 5 No. 1 (2024): Progressive Physics Journal
Publisher : Program Studi Fisika, Jurusan Fisika, FMIPA, Universitas Mulawarman

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30872/ppj.v5i1.1038

Abstract

Dose Calibrator is one of the dosimeters used to measure radionuclide activity before being given to patients. In order to function as a radiation dosimeter, the dose calibrator must have several good dosimeter properties such as precision and stability. To test the dose calibrator, a source used by the hospital is required. One isotope that is widely used in the field of nuclear medicine, namely Tc-99m. The research steps this time are: firstly the elution performed by radiopharmaceuticals, secondly measuring background activity (background), thirdly calling for Tc-99m sources, fourthly measuring Tc-99m activity, fifthly calculating Tc-99m activity for testing precision, and sixth evaluate the results. Based on the research results on the precision test, it was found that the measurement results for the Tc-99m source were obtained at 0.578%. It can be concluded that the Capintec CRC 25R dose calibrator has good characteristics and performance, so that the measurement results can be trusted.
Kalibrasi Timbangan Elektronik Non-Otomatis di UPTD Balai Pengujian dan Sertifikasi Mutu Barang Samarinda Norliani, Norliani; Wardani, Pratiwi Sri; Putri, Erlinda Ratnasari; Jamaluddin, M. Nur
Progressive Physics Journal Vol 4 No 2 (2023): Progressive Physics Journal
Publisher : Program Studi Fisika, Jurusan Fisika, FMIPA, Universitas Mulawarman

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30872/ppj.v4i2.1010

Abstract

Scales are one of the vital measuring tools that have long been used by humans in everyday life. In determining the measurement quality of the scales, calibration is needed to determine the value of uncertainty. In this regard, a study was conducted to determine the uncertainty of non-automatic electronic scales calibrated using the E2 class standard, and to determine the quality of the instrument from the measurement results by looking at the uncertainty of the calibration results of non-automatic electronic scales. The calculation of the calibration of the electronic scales includes the magnitude of the measurement repeatability, correction of scale readings, the effect of loading not in the middle of the pan, and the effect of hysteresis from the scale by using the direct comparison method to the mass of the reference standard, namely by using the mass standard from class E2. From the calibration of the electronic scales that have been carried out, the results of the correction uncertainty value are 0.0002 g and the maximum uncertainty value is 0.00027 g, while the combined uncertainty is obtained a value of 0.00032 g, which means that the non-automatic Electronic Analytical Balance meets the uncertainty. determined by the standard used. In addition, the non-automatic Electronic Analytical Balance scale is included in good condition with hysteresis test indications of no more than one resolution.
Hubungan Suhu dan Kelembapan Ruangan Terhadap Sick Building Syndrome (SBS) di UPTD Balai Pengujian dan Sertifikasi Mutu Barang (BPSMB) Samarinda Lagihara, Chrismasisca Hanni Drescher; Wardani, Pratiwi Sri; Natalisanto, Adrianus Inu
Progressive Physics Journal Vol. 5 No. 1 (2024): Progressive Physics Journal
Publisher : Program Studi Fisika, Jurusan Fisika, FMIPA, Universitas Mulawarman

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30872/ppj.v5i1.1093

Abstract

Samarinda is one of the cities in East Kalimantan, in Samarinda itself there are many office buildings that use AC coolers. One of the office buildings in Samarinda is the Quality Testing and Certification Center of East Kalimantan’s Building (UPTD. Balai Pengujian dan Sertifikasi Mutu Barang Provinsi Kalimantan Timur). Room temperature and humidity greatly affect the level of worker productivity, but not many people understand the existence of sick building syndrome (SBS). The purpose of this study was to determine the characteristics of employees regarding SBS complaints based on age and length of work and to find out the description of room temperature and humidity at UPTD BPSMB. The type of research used is non-probability sampling with a descriptive approach. The sample in this study were UPTD BPSMB Samarinda employees with a sample size of 20 people. The sampling technique was determined by purposive sampling method. The results of this study showed that the most commonly experienced symptoms were dry skin (50%), drowsiness (40%), dry lips and fatigue (20%), eye irritation, headaches, and difficulty concentrating (15%). From the results of the cross-tabulations that were carried out, it was found that there was no relationship between temperature and SBS, age and SBS, and duration of work with SBS, Still, there was a relationship between humidity and SBS. It is suggested to the UPTD BPSMB to monitor the room at least once a month to see the temperature and humidity conditions of the room so that employees can work comfortably and can increase employee productivity.
Pengolahan Citra Digital EKG Rumah Sakit Tk.IV Samarinda Setyowati, Anggriya Feby; Wardani, Pratiwi Sri; Putri, Erlinda Ratnasari; Putri, Devina Rayzy Perwitasari Sutaji
Progressive Physics Journal Vol. 5 No. 1 (2024): Progressive Physics Journal
Publisher : Program Studi Fisika, Jurusan Fisika, FMIPA, Universitas Mulawarman

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30872/ppj.v5i1.1037

Abstract

In the hospital itself, especially in the MCU Poly Radiology Installation, it is a unit that performs services such as Medical Check Up, making health certificates, and carrying out routine checks at an institution. ECG examination is one of the services most frequently performed routinely by patients. Examinations carried out include medical check-ups, monitoring of long-term therapy, patient to assessment before surgery, individual screening for high-risk jobs, examinations before participating in sporting events, and overall examinations as a condition of employment. This study carried out the process of withdrawing information or object descriptions or identifying objects contained in images by compressing or reducing image data. By using EKG data from TK.IV Samarinda Hospital by carrying out processing stages such as converting analog data to digital, cropping, and applying filters to EKG images. After the filter is applied to the image, it is found that after 5 types of image processing (RGB Image, Grayscale Image, Binary Image, Thresholding Image, and Edge Detection Image) on the results of the ECG signal it can be concluded that the processed signal retains the features of the existing signal and information. . Of the five types of processing methods, the clearest result is conversion to Edge Detection imagery.