Estimasi Nilai Dosis Radiasi Yang Diterima Pasien Selama Pemeriksaan Angiografi Koroner Di RSUD DR Doris Sylvanus Palangka Raya Jackson Charlos; Putu Irma Wulandari; Kadek Sukadana
Nautical : Jurnal Ilmiah Multidisiplin Indonesia Vol. 1 No. 9 (2022): Nautical: Jurnal Ilmiah Multidisiplin Indonesia
Publisher : ARKA INSTITUTE

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Penerimaan dosis radiasi pada pasien Penggunaan media kontras menjadi kunci utama dalam pemeriksaan PCI (Percutaneous Coronary Intervention). Ada berbagai macam jenis media kontras salah satunya media kontras berbahan iodine. Penggunaan jumlah volume media kontras yang terlalu banyak dapat menyebabkan gangguan fungsi ginjal. Maka dari itu, jumlah volume media kontras perlu diperhatikan dalam penggunaannya untuk menghindari efek samping yang tidak diharapkan. Penelitian ini menggunakan penelitian kuantitatif deskriptif, Pengumpulan data dilakukan pada bulan juni - Juli 2022 di RSUD dr Doris Sylvanus Palangkaraya dengan dua cara yaitu, melakukan observasi dan dengan 10 tenaga kesehatan mengenai prosedur penggunaan media kontras pada pemeriksaan (PCI) pada bulan Oktober-Desember 2021 dan mendokumentasikan data 25 pasien yang mendapat media di buku register pasien RSUD Ulin Banjarmasin. Hasil dari penelitian ini yaitu 10 tenaga kesehatan yang diwawancara didapatkan hasil 1 topik yaitu prosedur penggunaan media kontras di RSUD Ulin Banjarmasin, meliputi beberapa sub topik. Dari 25 pasien yang diberikan media kontras pada pemeriksaan PCI didapatkan jumlah volume media kontras tertinggi yaitu 270mL dan jumlah media kontras terendah yaitu 70mL.
Analisis Multi Slice Computed Tomography (MSCT) Nasofaring Dengan Klinis Karsinoma Nasofaring Di Instalasi Radiodiagnostik RSUP Dr. Hasan Sadikin Bandung Destri Bestari Palimbong; Anak Agung Aris Diartama; I Kadek Sukadana
Jurnal Pengabdian Ilmu Kesehatan Vol. 3 No. 3 (2023): November: Jurnal Pengabdian Ilmu Kesehatan
Publisher : Lembaga Pengembangan Kinerja Dosen

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55606/jpikes.v3i3.2672

Abstract

Background: Nasopharyngeal carcinoma is cancer that occurs in the nasopharyngeal mucosa which shows squamous cell differentiation. MSCT has become a reliable imaging technique for assessing the extent of nasopharyngeal carcinoma. Nasopharyngeal MSCT examination procedure with clinical nasopharyngeal carcinoma at the Radiodiagnostic Installation of Dr. RSUP. Hasan Sadikin Bandung uses a head protocol and slice thickness of 3-5 mm. This study aims to determine the Nasopharyngeal MSCT examination procedure for clinical nasopharyngeal carcinoma using a head protocol with manual intravenous contrast injection. Method: The type of research used is descriptive qualitative research with a case study approach. This research was conducted at the Radiodiagnostic Installation of RSUP Dr. Hasan Sadikin Bandung The subjects in this study consisted of three patients, two radiographers and three radiologists. Data collection methods are carried out through observation, interviews and documentation. The data analysis technique used is an interactive analysis model.
Perbandingan Kualitas Citra CT-Scan Kepala Pada Kasus Trauma Dengan Variasi Increment Di Rumah Sakit Balimed Zulvania Do Rego Jesus; I Putu Eka Juliantara; I Kadek Sukadana
Calory Journal Medical Laboratory Journal Vol. 1 No. 4 (2023): December : Medical Laboratory Journal
Publisher : LPPM STIKES KESETIAKAWANAN SOSIAL INDONESIA

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.57213/caloryjournal.v1i4.91

Abstract

Trauma is emotional and psychological stress in general due to unpleasant events or experiences related to violence. The word trauma can also be used to refer to events that cause excessive stress. An event can be called traumatic if the event causes extreme stress and exceeds the individual's ability to cope. The results of research related to variations in reconstruction increments in trauma cases show that the optimal increment reconstruction value on CT scan trauma head case trauma value increment reconstruction 2,5mm. Type study is quantitative with an experimental approach to analysis Quality information Citra Ct-Scan head with variations iincrement case trauma, with variations of 0,7mm, 0,9mm. Data collection was carried out in August-September 2023 at Balimed Regional Hospital. The author took examination dataas many as 10 patients. Research results from uji normality test on an clinical CT scan of the head in trauma cases use variations increments reconstruction 0,7mm, 0,9mm, can be seen that the mean increment value 0,7 mm produces a mean of 38,56 in the Ventricle-GM area, 15, 13 in the WM-GM area. And the mean increment value 0,9mm produces a mean of 19,88 in the ventricle-GM area, 7,1 in the WM-GM area. From the normality test on CT scan of the head in trauma cases using increment variations reconstruction 0,7mm, 0,9mm, it illustrates the image quality of the 2 increment variations, namely the increment variation value of 0,7 mm has the highest CNR value, namely a mean of 38, 56 in the ventricular-GM area, in the WM-GM area it was 15,13. Meanwhile, the increment variation value 0,9 mm produces 19.88 in the ventricular-GM area, in the WM-GM area 7,1. So this shows that an increment variation 0,7mm is the most optimal increment variation in improving the image quality of a CT scan of the head in trauma cases
Evaluasi Nilai CTDIvol Dan DLP Pada Pemeriksaan MSCT Abdomen Kontras Selama Periode Januari-Maret 2023 Di RSUP Dr Hasan Sadikin Bandung : Dengan Pendekatan ALADAIP Anjelina Merry; Anak Agung Aris Diartama; I Kadek Sukadana
Jurnal Rumpun Ilmu Kesehatan Vol. 3 No. 3 (2023): November: Jurnal Rumpun Ilmu Kesehatan
Publisher : Lembaga Pengembangan Kinerja Dosen

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55606/jrik.v3i3.2684

Abstract

Background: Abdominal MSCT examination is a type of radiodiagnostic examination that uses the MSCT device. Considering that the abdomen is close to organs that have radiosensitive properties such as the gonads and ovaries, it is necessary to monitor the radiation dose received so that it does not exceed the predetermined I-DRL value. The prevalence of contrast Abdominal MSCT examinations in the Radiodiagnostic Installation at Dr Hasan Sadikin Bandung Hospital was recorded during the last 3 months, there were 327 Contrast Abdominal MSCT examinations out of a total of 880 examinations with a percentage of contrast Abdominal MSCT examinations of 0.37%. This proves that contrast Abdominal MSCT examinations are often carried out but evaluation has never been carried out regarding the radiation dose received by the patient. Method: The type of research used in this research is descriptive quantitative with an observational approach by collecting data from patients with contrast Abdominal MSCT examinations during the period January-March 2023 with a sample of 128 patients. The local DRL value is calculated using the 2nd quart formula in the SPSS statistical application, then this local DRL value is compared with the I-DRL value determined by BAPETEN. Results: Calculation of the 50th percentile value of CTDIvol and DLP on 128 samples. The results show a CTDIvol value of 15.91 mGy and DLP of 740 mGy*cm. The DRL (50 percentile) values ​​based on gender are 13.71 mGy and 743 mGy*cm for men, and 17.74 mGy and 792 mGy*cm for women. Based on abdominal thickness, patients with a thickness of 10-19 cm have values ​​of 12.19 mGy and 587 mGy*cm, while patients with a thickness of 20-30 cm have values ​​of 22.57 mGy and 965 mGy*cm. For the most clinical cases (Ca Recti) the values ​​were 11.27 mGy and 586 mGy*cm. Conclusion: The 2nd quartile value (50 percentile) of CTDIvol and DLP received by patients during the Contrast Abdominal MSCT examination at the Radiodiagnostic Installation of RSUP Dr. Hasan Sadikin Bandung is in accordance with the standard values ​​set by BAPETEN/I-DRL 2021. However, special attention is needed for patients with an abdominal thickness of 20-30 cm, where the CTDIvol value exceeds the standards set by BAPETEN/I-DRL 2021.
Analisis Nilai CTDIvol Dan DLP Pada Pemeriksaan CT Scan Brain Non Kontras Dewasa Untuk Periode Januari – Desember 2022 Di Instalasi Radiologi Rumah Sakit X Jakarta Pusat Pricilia Shalry Horuoby; Anak Agung Aris Diartama; I Kadek Sukadana
Jurnal Rumpun Ilmu Kesehatan Vol. 3 No. 3 (2023): November: Jurnal Rumpun Ilmu Kesehatan
Publisher : Lembaga Pengembangan Kinerja Dosen

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55606/jrik.v3i3.2687

Abstract

Background: CT scans are used for various types of examinations such as examinations of the head, thorax, abdomen and so on. The most frequently performed CT scan is a CT scan of the head. However, in the medical field, especially radiology, CT scans have the highest dose compared to other radiation equipment. Efforts to reduce radiation doses and radiation effects are by estimating the correct dose given to CT Scan patients using an optimization index called DRL (Diagnostic Level Reference), namely by evaluating the values ​​of CTDIvol and DLP on CT scans of the head, which have been determined in accordance with BAPETEN/I-DRL 2021 standards. Method: This research is a descriptive quantitative study with an observational approach which aims to analyze CTDIvol and DLP values ​​based on retrospective data on non-contrast brain CT scans at the Radiology Installation at Hospital X, Central Jakarta. Results: Calculation of the 2nd quartile (50th percentile) value of CTDIvol and DLP in Adult Non-Contrast Brain CT Scan examinations for the January-December 2022 Period at the Radiology Installation at X Hospital, Central Jakarta is CTDIvol 55.51 mGy and DLP 867.00 mGy* cm. Conclusion: The 50 percentile value of CTDIvol and DLP in the Adult Non-Contrast Brain CT Scan examination for the January-December 2022 period at the Radiology Installation at X Hospital, Central Jakarta is in accordance with the standards set by BAPETEN/I-DRL 2021. Where is the value for CT Non-Contrast Head Scan, namely a CTDIvol value of 60 mGy and a DLP value of 1275 mGy*cm.
Tingkat Pengetahuan Keluarga Pasien terhadap Lampu Indikator di Ruang Radiologi di RSU Kertha Usada Buleleng Genoveva Adventania Niron; Kadek Sukadana
Jurnal Ventilator Vol. 2 No. 3 (2024): September : Jurnal Ventilator
Publisher : Stikes Kesdam IV/Diponegoro Semarang, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.59680/ventilator.v2i3.1335

Abstract

Radiation protection is an action to reduce the impact of radiation arising from radiation exposure. Radiation sign lights are one of the requirements of x-ray aircraft facilities for radiation safety in hospitals intended for officers and the surrounding community in the radiology installation area. After the radiation indicator light is bright red and the door of the radiology examination room is closed, the patient's family is not allowed to enter so as not to be exposed to radiation or scattered radiation which has a very dangerous impact on health. The type of research used is a type of quantitative research using a descriptive method. This method aims to create an objective picture or descriptive description of a situation using numbers, starting from data collection, interpretation of the data as well as its appearance and results. The majority of respondents in this study were between 26 and 45 years old. The majority of respondents (78%) do not know about Indicator lights in the radiology room. Only (16%) or 8 respondents knew enough about the topic, and (6%) or 3 respondents knew it well. Based on the results of the study on "The Level of Patient Family Knowledge Regarding Indicator Lights in the Radiology Room at Kertha Usada Buleleng Hospital", the following conclusions can be drawn: The majority of respondents showed a low level of knowledge related to indicator lights. Analysis of demographic characteristics such as age, education, and gender significantly affects their level of knowledge.