PEMERIKSAAN CT STONOGRAFI PADA KASUS NEFROLITHIASIS I Putu Yudha Sambawitasia; Putu Irma Wulandari; Kadek Sukadana
JRI (Jurnal Radiografer Indonesia) Vol. 5 No. 2 (2022): November
Publisher : Perhimpunan Radiografer Indonesia (PARI)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55451/jri.v5i2.133

Abstract

ABSTRACT Background : CT Stonography is a CT scan tract of the kidney that is usually used to detect the presence of stones in the kidney and other pathologies such as the presence of mass in the kidneys. CT Stonography examination with kidney stones case in Buleleng Regional General Hospital using 5 mm slice thickness. The purpose of this study is to know the examination techniques, the reasons for the use of 5 mm slice thickness, and how to determine the size of kidney stones using CT Stonography in cases of nephrolithiasis at Buleleng Regional General Hospital. Methods : This type of research is qualitative with case study approach. The subjects were 2 radiographers, 1 radiologist, and 1 sending doctor. The location of the research at Radiology Installation Buleleng Regional General Hospital. Data were analyzed using by interactive model. Results : From the results of this study examination of CT Stonography at Buleleng Regional General Hospital uses special preparation of 12 hours of fasting before the examination. Position of supine patient (head first). Area scanning from diaphragm to symphisis pubis. Scan parameters using abdomen protocol, 10 mm slice thickness. The reason for using 10 mm slice thickness is that the image can be reconstructed with a thin slice thickness number from the previous result. How to determine the size of kidney stones in patients CT Stonography at Radiology Installation Buleleng Regional General Hospital is using 3 dimensions because to see from the axial, sagittal, coronal multiplanar so that we can measure from the posterior antero direction (AP), cranio caudal (CC), or laterolaterally taken from the widest distance. Conclusion : Examination CT Stonography with nephrolithiasis cases using the position of supine patients (head first), selection of 10 mm slice thickness on CT stonography examination techniques with nephrolithiasis cases at Radiology Installation Buleleng Regional General Hospital for the results of the image can be reconstructed with the amount of thin slice thickness of the previous results. Determination of the size of kidney stones in patients with CT Stonography at Radiology Installation Buleleng Regional General Hospital is using 3 dimensions because to see from the axial, sagittal, coronal multiplanar so that we can measure from the posterior antero direction (AP), cranio caudal (CC), and laterolateral taken from the widest distance.
ESTIMASI DOSIS RADIASI YANG DITERIMA PASIEN PADA PEMERIKSAAN THORAX PA Kadek Sari Anggarin; I Putu Irma Wulandari; Ni Putu Rita Jenyanthi
JRI (Jurnal Radiografer Indonesia) Vol. 5 No. 1 (2022)
Publisher : Perhimpunan Radiografer Indonesia (PARI)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55451/jri.v5i1.105

Abstract

Background : Radiation dose received by patients during medical radiology examination varied among practices. This is due to difference in techniques, filter, and equipment used during examinations. This study aims to determine the value of facilities Diagnostic Reference Level (fDRL) in Radiology hospitals district Buleleng and comparison of the 75th percentile value of radiation dose received by adult Thorax PA patients with the standards established by BAPETEN. Methods: This type of research uses a quantitative method with a survey conducted at the Radiology Installation of Buleleng Regency Hospital in February 2020. The population of this study was all patients who underwent radiographic examination of Thorax PA adults (over 15 years). While the sample in this study was 30 patients with Thorax PA radiography examination adult (over 15 years). Absorbent dose measurement data is carried out directly with a digital dosimeter measuring device and then processed using SPSS. Results and Conclusion: The results of this study obtained the value of facilities Diagnostic Reference Level for examination of adult PA Thorax in Radiology Installation of Buleleng Regency Hospital is 0.0275 mGy and the percentile value of 75 absorbent doses received by PA thorax patients adult in Radiology Installation of Buleleng Regency Regional Hospital is 0.0275 mGy where the dose Radiation absorption received by PA thorax patients has met the standards set by BAPETEN in the Indonesian Diagnostic Reference Level (IDRL) 2019 radiation absorbed dose received by adult thorax PA patients, which is 0.4 mGy.
Analisis Kompetensi Radiografer pada tindakan Percutaneous Coronary Intervention (PCI) di Kota Medan ditinjau dari Standar Kompetensi Kerja Nasional Indonesia Adrian Dirga Laurensius Siahaan; Putu Irma Wulandari; Suhariadi Atmanta
Nautical : Jurnal Ilmiah Multidisiplin Indonesia Vol. 1 No. 10 (2023): Nautical: Jurnal Ilmiah Multidisiplin Indonesia
Publisher : ARKA INSTITUTE

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Salah satu tindakan yang cukup tinggi ditangani di Kota Medan dalam radiologi intervensi yakni Percutaneous Coronary Intervention (PCI). Tujuan dari penelitian ini yaitu untuk mengkaji lebih dalam mengenai kesesuaian kompetensi radiografer interevensi khususnya di Kota Medan dengan pedoman Standar Kompetensi Kerja Nasional Indonesia (SKKNI). Penelitian ini merupakan penelitian kuantitatif dengan melakukan pendekatan deskriptif untuk mengetahui kesesuaian terhadap kompetensi radiografer pada tindakan Percutaneous Coronary Intervention di Kota Medan ditinjau dari Standar Kompetensi Kerja Nasional Indonesia (SKKNI) Radiografer yang berlaku. Penelitian ini menggunakan metode total sampling dengan melakukan kuesioner online google form dari bulan Mei – Agustus 2022. Hasil yang didapatkan dari perhitungan rumus kesenjangan (gap) adalah 0,25 sehingga tercapai persentase capaian kompetensi tertinggi dengan besaran nilai 95,83% pada unit kompetensi penatalaksanaan pemeriksaaan, sedangkan yang terendah terdapat pada unit persiapan peralatan dan perlengkapan dengan persentase capaian kompetensi sebesar 76,78% dan nilai kesenjangan (gap) sebesar 1,625.
PERAN RADIOGRAFER PADA TINDAKAN INTERVENSI CORONARY ANGIOGRAPHY (CAG) DI RUMAH SAKIT TK.II PELAMONIA MAKASSAR DITINJAU DARI STANDAR KOMPETENSI KERJA NASIONAL INDONESIA (SKKNI) Zanila Syarifa Alfian; Putu Irma Wulandari; Kusman Kusman
Nautical : Jurnal Ilmiah Multidisiplin Indonesia Vol. 1 No. 10 (2023): Nautical: Jurnal Ilmiah Multidisiplin Indonesia
Publisher : ARKA INSTITUTE

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Standar Kompetensi Kerja Nasional Indonesia (SKKNI) adalah rumusan kemampuan kerja yang mencakup aspek pengetahuan, keterampilan dan keahlian serta sikap kerja yang relevan dengan pelaksanaan tugas dan syarat jabatan yang ditetapkan. Sebagai upaya mematuhi pedoman dan standar yang telah ditetapkan maka dilakukan penelitian ini untuk mengkaji kesesuaian kompetensi radiografer pada tindakan intervensi Coronary Angiography (CAG). Penelitian ini menggunakan metode penelitian kualitatif dengan melakukan observasi, wawancara dan dokumentasi terhadap peran radiografer. Didapatkan dari 25 kompetensi radiografer pada SKKNI terdapat 22 kompetensi yang sesuai dan 3 kompetensi yang tidak sesuai, kompetensi yang tidak sesuai yaitu radiografer tidak mempersiapkan pesawat sinar-x angiografi intervensi, tidak mempersiapkan troly emergensi beserta perangkatnya (obat-obatan dan lain-lain) serta tidak melakukan edukasi terhadap pasien. Kompetensi radiografer di dalam SKKNI meliputi prosedur sebelum pemeriksaan, persiapan peralatan dan perlengkapan, persiapan pasien, prosedur penatalaksanaan pemeriksaan dan prosedur setelah pemeriksaan.
EVALUASI NILAI DEVIATION INDEX PADA PEMERIKSAAN RADIOGRAFI: PROPORSI OVEREXPOSURE DAN UNDEREXPOSURE MELEBIHI CITRA OPTIMAL Putu Irma Wulandari; Putu Oky Agnesia; I Wayan Gede Ari Mahardika; Ni Putu Meliani; Ni Putu Amara Trisna Dinda
Jurnal Ilmu Kedokteran dan Kesehatan Vol 10, No 2 (2023): Volume 10 Nomor 2
Publisher : Prodi Kedokteran Fakultas Kedokteran Universitas Malahayati

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33024/jikk.v10i2.9213

Abstract

Pada sistem Computed Radiografi (CR), radiografer dapat mengetahui apakah faktor eksposi yang digunakan untuk akuisisi gambar terlalu rendah atau terlalu tinggi melalui nilai Exposure Index. Exposure index merupakan indicator jumlah paparan radiasi yang sampai pada detector pada pemeriksaan radiologi. Tujuan dari penelitian ini adalah untuk mengetahui proporsi citra/radiograf yang berada pada rentang exposi optimal, overexposure, maupun underexposure. Metode: Penelitian ini merupakan penelitian kuantitatif deskriptif. Penelitian ini dilakukan pada salah satu rumah sakit milik pemerintah di daerah klungkung, Bali. Nilai DI untuk beberapa pemeriksaan dikumpulkan secara retrospective dari bulan Oktober 2021 hingga Maret 2022, melalui CR merk Fuji Film. Sebanyak 3933 data dari pemeriksaan Thorax (1195), Abdomen (444) dan Extremitas atas (1319) dan extremitas bawah (975) dikumpulkan dari penelitian ini. Selanjutnya, proporsi underexpose, optimal dan overexpose pada masing-masing pemeriksaan dihitung diolah dengan menggunakan Ms.Excel. Hasil: Hasil penelitian menunjukkan nilai Deviation Index berada diluar batas rekomendasi, dimana terjadi proporsi over exposure dan under exposure yang relatif tinggi, dengan persentase under exposure tertinggi pada pemeriksaan Thorax (97.2%), dan overexposure tertinggi pada pemeriksaan Abdomen (85.8%). Kesimpulan: Dengan proporsi under exposure dan over exposure yang cukup tinggi pada pemeriksaan Thorax, Abdomen, Ekstremitas Atas, dan Ekstremitas Bawah diperlukan  upaya perbaikan mutu pelayanan melalui program QA/QC sehingga dihasilkan radiograf yang bernilai diagnostic dengan dosis radiasi yang optimal.
Pengaruh Luas Bidang Penyinaran dan Delay Time Processing Terhadap Exposure dan Deviation Index Computed Radiography AGFA Seri CR10-X I Gede Erix Krisna Adi Pramartha; Ni Nyoman Ratini; Putu Irma Wulandari
BULETIN FISIKA Vol 24 No 2 (2023): BULETIN FISIKA August Edition
Publisher : Departement of Physics Faculty of Mathematics and Natural Sciences, and Institute of Research and Community Services Udayana University, Kampus Bukit Jimbaran Badung Bali

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24843/BF.2023.V24.i02.p02

Abstract

Abstract – Research has been carried out to determine the effect of irradiation area and delay time processing on the exposure index (EI) and deviation index (DI) of computer radiography (CR). The tools used are phantom skull, imaging plate (IP), grid, and CR. The exposure factor used is set constant. To find out the EI value, exposure was carried out with the following variations of the irradiation area, 25 cm x 25 cm, 25 cm x 28 cm, 28 cm x 30 cm, 30 cm x 36 cm and 30 cm x 43 cm. Then the exposure was carried out using a constant irradiation area of ??25 cm x 25 cm, but the delay time processing variations were carried out as follows, 5, 10, 15, 20, 25 minutes. The EI value is used to find the DI value. Next, a graph is made and a test is carried out in the form of a regression test to determine the relation between the area of ??irradiation on EI and delay time processing on EI. Path analysis was also carried out to determine the relation between the area of ??irradiation to DI and delay time processing to DI. The results of the regression test showed that the irradiation area and delay time processing had a significant effect on EI. The results of the path analysis test show that the area of ??irradiation has no significant effect on DI, while delay time processing and EI have a significant effect on DI. Key words: Exposure index, deviation index, delay time processing, irradiation area, computed radiography
Estimasi Nilai Dosis Radiasi Yang Diterima Pasien Selama Pemeriksaan Angiografi Koroner Di RSUD DR Doris Sylvanus Palangka Raya Jackson Charlos; Putu Irma Wulandari; Kadek Sukadana
Nautical : Jurnal Ilmiah Multidisiplin Indonesia Vol. 1 No. 9 (2022): Nautical: Jurnal Ilmiah Multidisiplin Indonesia
Publisher : ARKA INSTITUTE

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Penerimaan dosis radiasi pada pasien Penggunaan media kontras menjadi kunci utama dalam pemeriksaan PCI (Percutaneous Coronary Intervention). Ada berbagai macam jenis media kontras salah satunya media kontras berbahan iodine. Penggunaan jumlah volume media kontras yang terlalu banyak dapat menyebabkan gangguan fungsi ginjal. Maka dari itu, jumlah volume media kontras perlu diperhatikan dalam penggunaannya untuk menghindari efek samping yang tidak diharapkan. Penelitian ini menggunakan penelitian kuantitatif deskriptif, Pengumpulan data dilakukan pada bulan juni - Juli 2022 di RSUD dr Doris Sylvanus Palangkaraya dengan dua cara yaitu, melakukan observasi dan dengan 10 tenaga kesehatan mengenai prosedur penggunaan media kontras pada pemeriksaan (PCI) pada bulan Oktober-Desember 2021 dan mendokumentasikan data 25 pasien yang mendapat media di buku register pasien RSUD Ulin Banjarmasin. Hasil dari penelitian ini yaitu 10 tenaga kesehatan yang diwawancara didapatkan hasil 1 topik yaitu prosedur penggunaan media kontras di RSUD Ulin Banjarmasin, meliputi beberapa sub topik. Dari 25 pasien yang diberikan media kontras pada pemeriksaan PCI didapatkan jumlah volume media kontras tertinggi yaitu 270mL dan jumlah media kontras terendah yaitu 70mL.
Evaluasi dosis radiasi pasien pada pemerikasaan Coronary Angiography (CAG) dan pemerikasaan Coronary Angiography (CAG) + Percutaneous Coronary Intervention (PCI) di Rumah Sakit TK II Pelamonia Makassar Tahun 2021 Alvira Febriana; Putu Irma Wulandari; I Kadek Sukadana; Kusman Kusman
Nautical : Jurnal Ilmiah Multidisiplin Indonesia Vol. 1 No. 10 (2023): Nautical: Jurnal Ilmiah Multidisiplin Indonesia
Publisher : ARKA INSTITUTE

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Penyakit jantung koroner (PJK) adalah penyakit yang disebabkan oleh plak yang menumpuk di arteri koroner yang memasok oksigen ke otot-otot jantung. Tujuan dari penelitian ini untuk mengevaluasi dodsis radiasi pasien pada pemeriksaan Coronary Angiography dan Percutaneous Coronary Intervention di Rumah Sakit TK II Pelamonia Makassar tahun 2021. Penelitian ini menggunakan metode penelitian kuantitatif deskriptif dengan pendekatan survey untuk mengevaluasi nilai DAP dan Fluoro Time menggunakan jenis data retrospektif pada pemeriksaan Coronary Angiography (CAG) dan pemeriksaan Coronary Angiography (CAG) + Percutaneous Coronary Intervention (PCI) selama periode tahun 2021 di Rumah Sakit TK II Pelamonia Makassar. Hasil yang didapatkan dari perhitungan menggunakan SPSS Percentile 75 pada pemeriksaan Coronary Angiography (CAG) sebanyak 18 pasien dengan rata-rata dosis DAP sebesar 26.48 Gy.cm2 dan Fluoro Time sebesar 362.50 Second dan Percentile 75 dosis DAP sebesar 28.83 Gy.cm2 dan Fluoro Time sebesar 496.25 Second. Kemudian pada pemeriksaan Coronary Angiography (CAG) + Percutaneous Coronary Intervention (PCI) sebanyak 11 pasien dengan rata-rata dosis DAP sebesar 45.96 Gy.cm2 dan Fluoro Time sebesar 777.18 Second dan Percentile 75 dosis DAP sebesar 58.22 Gy.cm2 dan Fluoro Time sebesar 1065.00 Second.
Peranan Sekuen T1 SPACE Coronal Pada Pemeriksaan MRI Brain Dengan Klinis Epilepsi Lobus Temporal Di Unit Radiologi RSUP Prof. Dr. I.G.N.G. Ngoerah Denpasar Riana Mageles Lodia Panie; Putu Irma Wulandari; Triningsih Triningsih; Anak Agung Ayu Meidiary
Jurnal Ilmu Kesehatan dan Gizi Vol. 2 No. 1 (2024): Januari : Jurnal Imu Kesehatan dan Gizi
Publisher : Pusat Riset dan Inovasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55606/jikg.v2i1.2099

Abstract

Background: Magnetic resonance imaging (MRI) is a cross-sectional imaging technique based on the principle of magnetic resonance of hydrogen atoms due to radio frequency (RF) signals with the same frequency as the precession frequency (lamor frequency). MRI at the beginning of its development used a semiconductor magnetic field with a power of 0.5-1.5 Tesla, but now MRI uses a superconductor magnetic field with a power of 1.5-3 Tesla. One of the advantages of brain MRI in epilepsy cases is that it can display clear information about the anatomy and pathology of the head in general in the temporal lobe area. The use of 3D sequences with isotropic voxels such as SPACE (Sampling Perfection With Application Optimized Contrasts With Varying Flip Angle Evolution) is very useful for generating images with high resolution, thinner cuts, and multi-level reconstruction can be performed in several fragments that allow the acquisition of 3D sequences at one time. Methods: The type used is descriptive qualitative research with a case study approach by conducting interviews with 2 radiology specialists, 1 neurology specialist and 3 radiographers related to MRI brain examinations with clinical epilepsy in August-September 2023 in the Radiology Unit of Prof. Dr. I. G. Ngoerah Denpasar Hospital. G. N. G. Ngoerah Denpasar. Results and Conclusion: This study used five (5) patient data who had clinical epilepsy. Based on the results of observations, interviews and documentation in the radiology unit of Prof. Dr. I.G.N.G. Ngoerah Denpasar Hospital, it can be seen that the procedure for examining MRI Brain with clinical epilepsy is that there is no special preparation, only filling out inform consent. The patient is positioned supine on the examination table with a head fixation device with a head first body position and hands beside the body. Radiographers put the patient into the gantry by setting the isocenter i n the middle of the glabella. After positioning the patient the radiographer sets the parameters using axial T2 Turbo Spin Echo (TSE), sagittal T2 Turbo Spin Echo (TSE), coronal T2 Turbo Spin Echo (TSE), axial T2 Turbo Spin Echo (TSE) dark fluit, axial T1 Turbo Spin Echo (TSE) axial Diffusion Weighted Imaging (DWI) and Susceptibility Weighted Imaging (SWI) and coronal T1 SPACE IR isotropic sequences.In addition, the role of coronal slice T1 SPACE sequences is to clearly see the presence of partical dystrophy, to see the thickening or irregularity of the cortex cerebri clearly. In addition, it is also to see the calcification of the temporal lobe and to measure the volume of the hippocampus.
Estimasi Dosis Radiasi Pada Pasien Pemeriksaan Percutaneous Coronary Interventions (Pci) Di RSUP Prof.Dr. I.G.N.G Ngoerah Clara Gusti Crisania Purba; Putu Irma Wulandari; I Kadek Sukadana
JURNAL RISET RUMPUN ILMU KEDOKTERAN Vol. 1 No. 2 (2022): Oktober :Jurnal Riset Rumpun Ilmu Kedokteran
Publisher : Pusat riset dan Inovasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55606/jurrike.v1i2.541

Abstract

Percutaneous Coronary Intervention (PCI) dikenal dengan angioplasty, merupakan prosedur non bedah yang dilakukan untuk mengobati arteri koroner stenotik (penyempitan) pada penderita jantung koroner. Pemeriksaan PCI dilakukan dengan menggunakan fluoroskopi dengan durasi fluorotime yang relatif lama dan resiko radiasi yang diterima semakin tinggi sehingga perlu adanya optimisasi dosis. Diagnostic Reference Level (DRL) merupakan salah satu alat yang digunakan untuk optimasi dosis radiasi. Tujuan dari Diagnostic Reference Level (DRL) adalah untuk mengoptimalkan proteksi dan keselamatan radiasi pasien, dan mencegah paparan radiasi yang tidak perlu. Nilai DRL Nasional ditentukan pada nilai kuartil 3 (75 persentil) dari data sebaran dosis yang didapat dari fasilitas kesehatan. Penelitian ini menggunakan data retrospektif, Data dosis yang digunakan untuk membandingkan DRL dalam Penelitian ini menggunakan data sekunder dari aplikasi Sistem Informasi Data Dosis Pasien (SiINTAN) tahun 2021 dengan total 187 pasien pada pemeriksaan Coronary Angiography. Dengan tujuan untuk mengevaluasi dosis radiasi DAP (Dose Area Product) dan Air Kerma pada pasien pemerisaan PCI. Dari perhitungan statistik 75 persentil (kuartil ke 3) pemeriksaan PCI pada dosis DAP yaitu 146.48 Gy.cm2 dan pada Air Kerma yaitu 2385 mGy, dan pada pasien yang sama tetapi terlebih dahulu melakukan pemeriksaan coronary angiography di RSUP Prof.Dr. I.G.N.G Ngoerah di tahun 2021 memiliki nilai persentil 75 pada DAP yaitu 45.83 Gy.cm2 dan pada dosis Air Kerma nilai yaitu 609 mGy. Perbandingan dengan negara lain nilai DRL Jepang 2020 bernilai 59 Gy.cm2 dan 700 mGy, Finland 2016 30 Gy.cm2.