Claim Missing Document
Check
Articles

Found 12 Documents
Search

Perbandingan Kualitas Citra CT-Scan Kepala Pada Kasus Trauma Dengan Variasi Increment Di Rumah Sakit Balimed Zulvania Do Rego Jesus; I Putu Eka Juliantara; I Kadek Sukadana
Medical Laboratory Journal Vol. 1 No. 4 (2023): December : Medical Laboratory Journal
Publisher : LPPM STIKES KESETIAKAWANAN SOSIAL INDONESIA

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.57213/caloryjournal.v1i4.91

Abstract

Trauma is emotional and psychological stress in general due to unpleasant events or experiences related to violence. The word trauma can also be used to refer to events that cause excessive stress. An event can be called traumatic if the event causes extreme stress and exceeds the individual's ability to cope. The results of research related to variations in reconstruction increments in trauma cases show that the optimal increment reconstruction value on CT scan trauma head case trauma value increment reconstruction 2,5mm. Type study is quantitative with an experimental approach to analysis Quality information Citra Ct-Scan head with variations iincrement case trauma, with variations of 0,7mm, 0,9mm. Data collection was carried out in August-September 2023 at Balimed Regional Hospital. The author took examination dataas many as 10 patients. Research results from uji normality test on an clinical CT scan of the head in trauma cases use variations increments reconstruction 0,7mm, 0,9mm, can be seen that the mean increment value 0,7 mm produces a mean of 38,56 in the Ventricle-GM area, 15, 13 in the WM-GM area. And the mean increment value 0,9mm produces a mean of 19,88 in the ventricle-GM area, 7,1 in the WM-GM area. From the normality test on CT scan of the head in trauma cases using increment variations reconstruction 0,7mm, 0,9mm, it illustrates the image quality of the 2 increment variations, namely the increment variation value of 0,7 mm has the highest CNR value, namely a mean of 38, 56 in the ventricular-GM area, in the WM-GM area it was 15,13. Meanwhile, the increment variation value 0,9 mm produces 19.88 in the ventricular-GM area, in the WM-GM area 7,1. So this shows that an increment variation 0,7mm is the most optimal increment variation in improving the image quality of a CT scan of the head in trauma cases
Analisis CT Scan Urografi dengan Klinis Batu Saluran Kemih di Instalasi Radiologi Rumah Sakit Bhayangkara Makassar Surtika Umar; I Putu Eka Juliantara; I Kadek Sukadana
Compromise Journal Community Proffesional Service Journal Vol. 1 No. 4 (2023): Compromise Journal : Community Proffesional Service Journal
Publisher : LPPM STIKES KESETIAKAWANAN SOSIAL INDONESIA

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.57213/compromisejournal.v1i4.35

Abstract

Background: Urinary tract stones are the growth of hard, stone-like masses in the human urinary tract. The prevalence of urinary tract stones (BSK) in Indonesia is still not known for certain, but estimates suggest that there are around 170,000 cases of BSK every year. CT Scan is a radiological examination modality for diagnosing urinary tract stones with a sensitivity level of around 95%-100% and a specificity level of around 96%-98% for detecting urinary tract stones, so CT Scan is considered the gold standard in diagnosing this condition. Research Objectives: This study aims to determine the management of CT Scan Urography in clinical urinary tract stones in the Radiology Installation of Bhayangkara Hospital, Makassar. Method: This research used descriptive qualitative research with a case study approach, the research subjects consisted of 3 radiographers, 1 radiologist, and 1 sending doctor. Data collection was carried out through several stages, namely observation, interviews and documentation. Results: The results of research at the Radiology Installation of Bhayangkara Hospital, Makassar. The procedure for CT Scan Urography examinations in clinical urinary tract stones is that the patient drinks 750 ml of fresh tea until he feels like he wants to urinate, then the examination is carried out. The role and effect of giving plain tea can increase HU (Hounsfield Unit) density and also speed up diuresis, thereby helping to shorten examination time. The excess caffeine content of plain tea can speed up the process of increasing urine volume, thereby shortening the examination time..