p-Index From 2020 - 2025
0.702
P-Index
This Author published in this journals
All Journal ALTRON
Claim Missing Document
Check
Articles

Found 4 Documents
Search

ANALISIS PENGEMBANGAN MODEL PEMANFAATAN ENERGI TERBARUKAN SEBAGAI SUPLAI DI UNIVERSITAS TEKNOLOGI SUMBAWA MENGUNAKAN HOMER Wardana, Satria Jaya; Maulidyawati , Desi; Ariyanto, Nova; Aulia, Masyitah
Jurnal Altron Jurnal Elektronika, Sains & Sistem energi
Publisher : Program Studi Teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51401/altron.v1i1.3284

Abstract

Potensi energi terbarukan jika dipakai untuk pengembangan sistem pembangkit tenaga listrik untuk mensuplai kebutuhan energi listrik Universitas Teknologi Sumbawa khususya Gedung rektorat hingga 20 tahun ke depan dapat disimulasikan menggunakan Software Homer. Tujuan penelitian ini adalah untuk mengetahui potensi EBT sebagai alternatif suplai kebutuhan listrik di Universitas Teknologi Sumbawa. Metode penelitian yang digunakan merupakan jenis penelitian eksperimen dengan menggunakan aplikasi HOMER. Pemodelan dan simulasi menggunakan HOMER, diperoleh hasil dan data pemodelan kebutuhan energi yang sesuai untuk mengoperasikan beban listrik di Universitas Teknologi Sumbawa. Dari pemodelan yang sudah dilakukan menggunakan aplikasi HOMER, maka diketahui bahwa jika besar sensitifitas radiasi matahari yang diterima PV (photo voltaic) adalah sebesar 5,048 kWh/ /hari, dengan menggunakan sebanyak 145 buah unit PV dapat memenuhi kebutuhan energi listrik di UTS khususnya pada Gedung Rektorat.Sehinga menghasilkan Net Present Cost (NPC) sebesar Rp 709,730,749.48 dan Cost of Energy (COE) sebesar Rp 1,095.36
STUDI KELAYAKAN SISTEM PLTS ROOFTOP PADA GEDUNG LAB INTEGRATED UNIVERSITAS TEKNOLOGI SUMBAWA Anfasyahbil, Moh; Darmawan , Indra; Ali Topan, Paris; Maulidyawati , Desi; Indah Kencana, Putri
Jurnal Altron Jurnal Elektronika, Sains & Sistem energi
Publisher : Program Studi Teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51401/altron.v3i2.3292

Abstract

Perguruan tinggi memiliki peranan penting bagi masyarakat serta lingkungan sekitar, dan dapat menjadi kunci dalam pengembangan pembangkit Energi Baru Terbarukan (EBT). Salah satu contohnya seperti pemanfaatan PLTS rooftop yang diaplikasikan pada atap gedung-gedung Kampus. Penelitian ini bertujuan bertujuan untuk mengevaluasi kelayakan pemasangan PLTS rooftop on-grid pada gedung Lab Integrated Universitas Teknologi Sumbawa (UTS) dengan fokus pada potensi energi listrik yang dihasilkan dan aspek biaya. Simulasi perancangan PLTS dilakukan menggunakan software PV Syst, dengan fokus objek penelitian pada area atap Gedung Lab Integrated UTS dengan luasan total sebesar 754 m2. Berdasarkan hasil simulasi, diperkirakan bahwa sistem PLTS atap pada kondisi optimal dapat menghasilkan sekitar 168.941 kWh energi listrik per tahun. Nilai kelayakan teknis ditinjau dari performance ratio (PR) yang didapatkan sebesar 77,38%. Sedangkan untuk hasil analisis ekonomi menunjukkan nilai cost of energy (COE) sebesar Rp 705.854/kWh, net present value (NPV) menghasilkan nilai positif sebesar Rp Rp 907.811.227 nilai Internal Rate of Return (IRR) sebesar 6,20%, Return on Investment (ROI) sebesar 65,6%, dengan pengembalian modal awal atau niali payback periode (PP) diperkirakan akan kembali dalam kurun waktu 9,3 tahun, Hasil tersebut mengindikasikan bahwa investasi untuk proyek sistem PLTS atap on grid pada gedung Lab intergrated layak untuk direalisasikan.
ANALISIS POTENSI ANGIN DAN SURYA DI UNIVERSITAS TEKNOLOGI SUMBAWA SEBAGAI STUDI KELAYAKAN PEMBANGKIT LISTRIK TENAGA HIBRID (PLTH) MENGGUNAKAN HOMER 3.16 suhardin; Jaya , Ahmad; Maulidyawati , Desi; Hidayatullah, Muhammad
Jurnal Altron Jurnal Elektronika, Sains & Sistem energi
Publisher : Program Studi Teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51401/altron.v3i2.3652

Abstract

Renewable energy is an energy source that can be obtained continuously from nature such as the sun, wind, water, geothermal, and biomass. According to the Directorate General of EBTKE in 2018, the total potential of renewable energy in Indonesia is 442 GW while the newly utilized is only 8.8 GW, therefore, there needs to be action to analyze the opportunity to add energy through calculations with Homer 3.16 software to see whether the Renewable Energy Power System can be applied. The purpose of this study is to find out how big the potential of wind and solar energy for the feasibility of building PLTH at Sumbawa University of Technology (UTS). The research method used is quantitative by collecting data in the form of solar irradiation, data on the load of electricity use around the UTS campus area and wind speed. Then the analysis method uses the HOMER software application. The results of HOMER 3.16 modeling, obtained that the modeling of the PLTH system in the UTS area at the condition of the average wind speed on the turbine of 3.13 m / s, solar irradiation received by solar panels of 5.59 kWh / m ^ 2 / day, then obtained a total production of 62.042 kWh of electrical energy per year with a total "Renewable Penetration" of 97.9%. 
EFISIENSI SISTEM KELISTRIKAN PADA GEDUNG SUMBAWA TECHNO PARK(STP) UNIVERSITAS TEKNOLOGI SUMBAWA Muhammad Surya Aqidah; Darmawan , Indra; Ariyanto, Nova; Maulidyawati , Desi; Aulia, Masyitah
Jurnal Altron Jurnal Elektronika, Sains & Sistem energi
Publisher : Program Studi Teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51401/altron.v3i2.3696

Abstract

Tingkat konsumsi dan distribusi energi listrik harus seimbang dan efisien. Akan tetapi, tidak semua sektor atau bangunan mampu memenuhi tingkat efisiensi yang telah ditentukan. Gedung Sumbawa Techno Park (STP) Universitas Teknologi Sumbawa sebagai konsumen energi listrik tingkat menengah, kiranya perlu dilakukan analisis peluang penghematan energi, guna mengetahui tingkat efisiensi konsumsi energi. Tujuan dari penelitian ini adalah untuk menganalisis peluang penghematan energi yang dilakukan melalui audit energi singkat dengan panduan Permen ESDM No. 13/2012 tentang audit energi listrik awal yang berfokus dengan luas bangunan gedung STP sekitar 720.63 (????????). Metode yang digunakan dalam penelitian ini adalah metode campuran (Mixed Method Research), Hasil dari penelitian diperoleh IKE pada kWh gedung Sumbawa Techno Park (STP) sebesar 69,93 kWh/m2/tahun. Nilai tersebut termasuk dalam kategori efisien menurut standar nilai IKE ASEAN-USAID yakni untuk gedung jenis perkantoran nilai IKE maksimum adalah 240 kWh/m2/tahun. Pada ruangan ber-AC diperoleh nilai rata-rata IKE sebesar 34,20 kWh/m2/bulan. Sedangkan pada ruangan tidak ber-AC diperoleh nilai rata-rata IKE sebesar 0,80 kWh/m2/bulan. Nilai IKE pada ruangan ber-AC dan tidak ber-AC masing-masing termasuk dalam kategori cukup efisien dan sangat efisien menurut permen ESDM No. 13/2012.