Hudayari, Devatri
Unknown Affiliation

Published : 3 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 3 Documents
Search

Unusual Lifespan of Edwards' Syndrome in COVID-19 Era Suryaningrat, Filla Reviyani; Hudayari, Devatri; Amalda Ediwan, Natasha; Rita Mardhiya, Wan; Aprilia Kadi, Fiva; Primadi, Aris; Yuniati, Tetty
Majalah Kedokteran Bandung Vol 56, No 3 (2024)
Publisher : Faculty of Medicine, Universitas Padjadjaran

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.15395/mkb.v56.3230

Abstract

Edwards' syndrome is caused by an extra chromosome on the 18th chromosome. Patients with this diagnosis have median survival of only 3-14.5 days, with the majority of infants with full trisomy 18 type die before or shortly after they are born. There is only supportive treatment available for Edwards’ syndrome. During the COVID-19 pandemic, providing health services was challenging, leading to less than optimum treatments added by patients’ reluctance to visit healthcare facilities due to the fear of COVID-19 transmission. This case study presented an infant with Edwards’ syndrome with major malformation. The patient had several organ problems, was admitted to the NICU, and continued with home care for monitoring for 6 months. Patient then died at 9 months of age. Maintaining the best quality of life for this patient was very challenging for parents and healthcare providers. Since the management for this type of sydnome is more palliative, good education, information, and psychosocial supports for the parents are needed to prepare them with the worst conditions, which was especially more challenging during the COVID-19 pandemic.
A Case Study on Neurological Outcome in Persistent Neonatal Hypoglycemia in Upper Middle-Income Country Primadi, Aris; Yuniati, Tetty; Aprilia Kadi, Fiva; Reviyani Suryaningrat, Filla; Hudayari, Devatri; Ediwan, Natasha Amalda
Majalah Kedokteran Bandung Vol 56, No 4 (2024)
Publisher : Faculty of Medicine, Universitas Padjadjaran

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.15395/mkb.v56.3350

Abstract

In Indonesia, comprehensive management and monitoring of persistent neonatal hypoglycemia, is rarely reported. Despite the fact that there are studies highlighting the risk of neurodevelopmental disorders in neonates with hypoglycemia, there seems to be limited comprehensive case reports detailing both the early diagnosis and the long-term growth and development monitoring in these neonates. A unique case report of a 10-day-old male baby, born at a term weeks gestation via caesarean section, diagnosed with persistent hypoglycemia and suspect of hyperinsulinemia is presented in this study. At birth, the neonate exhibited hypoglycemia with a blood glucose level of 25 mg/dL, accompanied by a one-minute seizure characterized by upward gaze and stiffening of the extremities. The neonate cried after seizure and there was no loss of consciousness and was admitted to the NICU due to worsening respiratory distress. Based on the thoracic X-ray examination, he was diagnosed with transient tachypnea of newborn (TTN). Blood glucose levels were monitored every four hours, and tests for cortisol, thyroid and growth hormone and routine urinalysis were planned. Total parenteral nutrition (TPN) were given with intravenous antibiotics. At 6months of age, the infant was diagnosed with intellectual disability by the growth and development social pediatric unit. At 7 months, the infant  began undergoing physiotherapy. This case was followed for 7 months in total and the findings highlight the challenges in managing neonatal persistent hypoglycemia and the potential long-term developmental implications in neonates with early-life hypoglycemia, emphasizing the need for continual growth and development monitoring.
Umbilical Venous Catheter Position Evaluation in Hasan Sadikin General Hospital : Overview of the Time Required Suryaningrat, Filla Reviyani; Primadi, Aris; Kadi, Fiva Aprilia; Hudayari, Devatri; Ediwan, Natasha Amalda; Yuniati, Tetty
Archives of Pediatric Gastroenterology, Hepatology, and Nutrition Vol. 3 No. 2 (2024): APGHN Vol. 3 No. 2 May 2024
Publisher : The Indonesian Society of Pediatric Gastroenterology, Hepatology, and Nutrition

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58427/apghn.3.2.2024.8-14

Abstract

Background: An umbilical venous catheter (UVC) is one of the most frequently used access in neonates. In developed countries, bedside ultrasonography (USG) is used in assessing the position of the UVC catheter’s tip. However, this is difficult to be implemented in developing countries. In Indonesia, which categorized as a middle- income developing country, the evaluation of UVC mainly used chest radiographs. However, this procedure would take time. The delay in ascertaining UVC positioning through chest radiography among neonatologists in Indonesia remains unstudied, despite its potential on the clinical efficacy. Therefore, this study aimed to determine the time required for the installation of the UVC and the interval from the completion of UVC insertion until the release of the chest radiography result. Method: In this prospective observational cohort study, neonates requiring UVC access were examined in Dr. Hasan Sadikin Hospital in Bandung, West Java. Patients underwent anthropometric measurements and UVC installation. Duration required for UVC installation and the interval between the completion of UVC insertion and the release of the chest radiography result were documented. Descriptive data were shown in percentage, mean and standard deviation. Result: 127 neonates were studied. The average time taken for UVC insertion was 31 minutes and the average time taken from the completion of UVC insertion until the release of chest radiography results was 6 hours. Conclusion: The long wait for chest radiography results significantly delayed the administration of fluids, medications, and parenteral nutrition in this study. Therefore, we need alternative tools to evaluate the UVC location that can be used bedside right after the installation.